Lighting and Shutdown Instructions

(Replaces pg. 18 in instruction manual.)

FOR YOUR SAFETY READ BEFORE

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

B. BEFORE OPERATING smell all around the ance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle to the

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions

If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to slide the gas control switch. Never use tools. If the switch cannot be moved by hand, do not try to repair it, call a service technician. Force or attempted repair may result in a fire or

D. Do not use this appliance if any part has been under water. Immediately call a qualified technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Turn off all electric power to the appliance

3.Set the thermostat to lowest setting.

4.This appliance is equipped with an ignition device which

lights the pilot. Do not try to light the pilot by hand.

SWITCH SHOWN

IN "ON" POSITION

STATUS

HoneywellON

6.Wait five (5) minutes to clear out any gas. Smell for gas, including near the floor.

If you the smell gas, STOP! Follow "B" in the safety information at left on this label. If you don't smell gas, go to the next step.

7.Slide the switch on the right side of the gas valve up to the "ON" position.

8.Set thermostat to desired setting.

OFF VERY

HOT

B C

A

HOT

LOW

THERMOSTAT

DIAL

5.Slide the switch on the right side of the gas valve down to the "OFF" position

9.Turn on all electric power to the appliance.

10.If the appliance will not operate, follow the instructions "To Turn Off Gas To Appliance" and call your

technician or gas

TO TURN OFF GAS TO APPLIANCE

1.

Turn off all electric power to the

3. Slide the switch on the right side of the

 

appliance if service is to be

gas valve down to the "OFF" position.

2.

Set the thermostat to the lowest setting.

 

 

 

 

3

Image 3
Contents Congratulations Minimum Clearances Minimum Clearances for an Alcove InstallationLighting and Shutdown Instructions For Your Safety Read BeforeThermostat Adjustment Burner Flame Check Installation for Potable Water Parts List Drawing Parts List Page Page Electrical Connections Honeywell Wiring DiagramTroubleshooting Troubleshooting Control Sequence of Operation Start up Sequence

PE-2-XR504T6FBN, PE-4-40T6FBN, PE-4-5036FBN, 48248A, 238-48248-00 specifications

Bradford-White Corporation is a prominent name in the water heating industry, known for its innovative solutions that meet the demands of both residential and commercial applications. Among its extensive product lineup, the PE-4-403S6FBN, PE-2-XR504T6FBN, PE-4-5036FBN, 48248A, and PE-4-40T6FBN models stand out due to their advanced features and reliable performance.

The PE-4-403S6FBN model is a high-efficiency water heater that utilizes a power venting system. This technology allows for optimal ventilation options, enabling the unit to be installed in a variety of locations, including tighter spaces. It provides a consistent supply of hot water, making it suitable for homes with moderate to high demand. The energy factor rating of this model is impressive, ensuring reduced energy consumption and lower utility bills, all while delivering superior performance.

Following suit in efficiency, the PE-2-XR504T6FBN model incorporates advanced modulating technology. This feature enables the unit to adjust its heating output based on demand, which not only enhances user comfort but also contributes to energy savings. The digital display on this model allows for easy monitoring and adjustments, making it user-friendly and highly efficient.

The PE-4-5036FBN model stands out with its robust build and impressive durability. Designed for high-efficiency operation, it features Bradford-White's proprietary combustion system, which promotes cleaner and more efficient fuel usage. This not only ensures reliable performance but also helps in maintaining lower emissions, making it an environmentally friendly option.

The 48248A model emphasizes safety and convenience with its built-in alarm systems that provide alerts for potential issues, ensuring peace of mind for users. Additionally, it is crafted for low maintenance, enhancing the overall user experience with longer lifespans and reduced servicing needs.

Lastly, the PE-4-40T6FBN model offers one of the highest capacities in its class, making it ideal for larger households requiring significant hot water access. Its energy-efficient design does not compromise performance, as it continuously supplies hot water without long recovery times, ensuring comfort for users.

In summary, Bradford-White's PE series integrates cutting-edge technologies, innovative features, and robust designs to deliver effective water heating solutions that meet diverse consumer needs while prioritizing energy efficiency and environmental concerns.