TWO TEMPERATURE - ONE HEATER HIGH TEMPERATURE

WITH RECIRCULATION OF SANITIZING LOOP

CAUTION: If the plumbing requires the use of pipes with dissimilar material (for example, steel and copper), use dielectric unions to prevent an electro-galvanic action between the piping components with dissimilar materials.

DANGER

TEMPERATURE SETTING SHOULD NOT EXCEED SAFE TEMPERATURE AT FIXTURES. SEE WATER TEMPERATURE CONTROL WARNING ON PAGE 5. IF HIGHER PREHEAT TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT, ADD AN ANTI-SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES.

CAUTION: IF BUILDING COLD WATER SUPPLY HAS A BACK-FLOW PREVENTER, CHECK VALVE OR WATER METER WITH CHECK VALVE PROVISIONS FOR THERMAL EXPANSION OF WATER IN THE HOT WATER SYSTEM MUST BE PROVIDED.

*PIPE RELIEF VALVE TO OPEN DRAIN

INSTALL IN ACCORDANCE WITH LOCAL CODES

NOTE 1: TOGGLE SWITCH CONTROLS 180°F (82°C) WATER CIRCULATION. INSTALL ON OR CLOSE TO DISHWASHER. TOGGLE SWITCH MUST BE CLOSED (ON) DURING THE RINSE OPERATION AND OPEN (OFF) WHEN DISHWASHER IS NOT OPERATING OR WHEN ON LONG STANDBY.

NOTE 2: INSTALL LINE TEMPERATURE CONTROL IN AN UNINSULATED TEE BEYOND THE DISHWASHER TAKEOFF IN THE SANITIZING LOOP. CONTROL SHOULD BE SET AT 185°F (85°C).

NOTE 3: ADJUST PLUG COCK SO THE SANITIZING LOOP FLOW RATE DOES NOT CAUSE UNNECESSARY TURBULENCE IN THE TANK.

NOTE 4: IF TEMPERED WATER IS RECIRCULATED, RETURN LINE SHOULD BE CONNECTED AT POINT A.

32

Image 32
Contents Commercial GAS Water Heater PrintedTemperature Rise Degrees F Gallons PER Hour ForewordAHCG3 HCG3Table of Contents FeaturesInstallation Instructions Locating the Heater ClearancesHard Water AIR RequirementsMechanical Exhausting of Room AIR Unconfined SpaceBELOW. Keep Clear of ALL Obstructions Power Vent Canadian Power VentDirect Vent Canadian Direct VentDirect Vent Terminal Installation Installation SequenceDirect Venting Masonry Side WallsVertical Vent Terminal Installation Installation of Vent System Vent Pipe PreparationInitial Preparation Selection of MaterialsControls and Switches GAS PipingConnection of GAS Pipe Attaching gas supply pipe to gas valve inletSystem Connections Heater Wiring Using the Electronic Controller OverviewOperating States Changing the Display Units Viewing the Fault History Prior to Start UPAdjustment Procedure Operating InstructionsMaintenance General InformationFor Your Safety Read Before Operating AHCG3/HCG3100T150 Models only AHCG3/HCG3100T199 & AHCG3/HCG3100T250 Models only Powered Anode System FlushingDraining Sediment RemovalDrain Valve and Access Panels Vent SystemInstallation Diagrams Page Must be Identical Heaters Page Page Manifold Kits Checklist and Service Information TROUBLE-SHOOTINGReplacement Parts Motor will not RUNMotor RUNS, Burner Lights Momentarily Then Locks OUT GAS Fails to Shut OFFCommercial Limited Warranty Page Page Page PO Box 1597, 500 Princeton Road Johnson City, TN Phone

AHCG3/HCG3100T250, AHCG3/HCG360T120 specifications

The American Water Heater AHCG3/HCG360T120 and AHCG3/HCG3100T250 are innovative models designed to meet the diverse needs of residential and commercial water heating. These state-of-the-art water heaters provide exceptional performance, efficiency, and reliability, making them ideal choices for consumers seeking long-lasting solutions for their hot water needs.

Both models are equipped with a robust design and advanced technology, ensuring effective operation and streamlining maintenance. The AHCG3/HCG360T120 has a capacity of 60 gallons, making it suitable for larger households or commercial applications, while the AHCG3/HCG3100T250 has a higher capacity of 100 gallons, providing ample hot water for multiple simultaneous uses.

One of the standout features of these water heaters is their high energy efficiency. Both models are designed to reduce energy consumption, translating to lower utility bills. The units are equipped with environmentally friendly insulation, which minimizes heat loss and maintains the temperature of the stored water longer. This construction not only conserves energy but also ensures consistent hot water delivery.

Innovative heating technology is another characteristic that sets the AHCG3/HCG series apart. These water heaters employ a combination of reliable heating elements and advanced electronics to provide precise temperature control. This technology ensures that users have access to hot water whenever they need it without significant waiting periods.

The American Water Heater AHCG series also emphasizes ease of use and installation. Each unit features user-friendly controls that allow for easy adjustment of temperatures and settings. The compact design ensures they fit comfortably in various spaces, making installation seamless in basements, utility rooms, or garages.

Durability and reliability are key aspects of these water heaters. Made with high-quality materials, they are designed to withstand the rigors of daily use while adhering to strict industry standards. Their robust construction minimizes the risk of leaks and ensures a long operational lifespan.

In summary, the American Water Heater AHCG3/HCG360T120 and AHCG3/HCG3100T250 models combine advanced technology, energy efficiency, and durability. These features make them excellent investments for anyone seeking a dependable hot water solution for their home or business, providing peace of mind and a reliable supply of hot water.