American Water Heater 318281-000 instruction manual Ocf

Page 29

OCF:

Antifreeze function

Adjustment: OFF / ON

Default setting: OFF

Recommended setting: OFF

CFR:

Antifreeze temperature Adjustment range:

15 to 50 °F

Default setting: 40 °F

Recommended setting: 40 °F

Channel only available when OCF is active

Channel only available when OCF is active

OREC:

Recooling function

Adjustment: OFF / ON

Default setting: OFF

Recommended setting: ON

OTC:

Tube collector function

Adjustment: OFF / ON

Default setting: OFF

Recommended setting: OFF

OHQM:

Heat quantity measurement

Adjustment: OFF / ON

Default setting: OFF

Recommended setting: OFF

FMAX:

Volume flow in gal/min

Adjustment range:

0.0to 20.0 in steps of 0.1 Default setting: 6.0

Recommended setting: pump station flow meter reading.

Channel only available when OHQM is active

MEDT:

Type of antifreeze

Adjustment range: 0 to 3

Default setting: 1

Recommended setting: 1

Channel only available when

OHQM is active.

This function is used to transfer heat from the storage tank to the collector in order to avoid freezing of the heat transfer medium is some system types.

This system uses a solution of propylene glycol and water and is freeze resistant to -30 °F; therefore, this function is not necessary.

The recooling function is used to cool the tank when the maximum tank temperature (S MX) is exceeded, such as when the collector cooling function (OCX) is activated and the tank may reach 203 °F (emergency shut down of the tank).

When the collector is 5° cooler than the tank the pump will run to dump excess heat from the tank in the piping and at the solar collector until the tank is cooled to the maximum tank temperature setting.

The tube collector function is only needed for systems that use vacuum tube solar collectors.

This function is not necessary for this system.

A Heat quantity measurement is possible for this system in conjunction with the flow meter. In order for this function measure the heat gain of the system the optional temperature sensor 4 (return flow sensor) must be added and connected to the copper pipe between the coil outlet on the tank (marked “to pump”) and the solar pump station.

For OHQM to give an accurate reading the volume flow readable at the flowmeter (gal/min) must be adjusted in the channel FMAX.

For OHQM to give an accurate reading the type of heat transfer fluid type(antifreeze) must be set in the channel MEDT:

0:water

1:propylene glycol

2:ethylene glycol

3:Tyfocor ® LS / G – LS

Caution: for this system type only type 1: propylene glycol should be selected. Use of any other type of heat transfer fluid in this system may cause damage to the system or present a health hazard

29

Image 29
Contents Residential Solar Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety System Description Preparing for the InstallationIntroduction Table of Contents Do not CAP Or Plug System DIAGRAM/TYPICAL InstallationTEMPERATURE-PRESSURE Relief Valve Storage Tank InstallationSystem Component Part Component FunctionWater Piping Closed SYSTEM/THERMAL ExpansionLocating the Solar Water Heater Filling the Solar Water Heater with Water Installation in Residential GaragesWiring of Element Temperature Settings Temperature RegulationThermostat Hotter Water can Scald Solar water heaters areDraining Temperature AdjustmentTank Sensor Element Element ReplacementAnode Water Heater SoundsGeneral Considerations Solar Collector InstallationCollector Location Collector Orientation Spanner Mounting Mounting Attaching Collector to Mounting Brackets Collector Piping Copper Cap InletSensor Mounting AT Collector Collector Piping DetailPipe Insulation Preparation of the Heat Transfer FluidSafety Instructions Pump Station InstallationPump Station ComponentsMounting the solar pump station to the wall Safety EquipmentCheck valves Plumbing ConfigurationFunction START-UP and Operation of the Solar Pump Station FlowmeterLeak Detection FlushingFilling Operation and Function Pump Station Control InstructionsControl Instructions Channel indication System Monitoring DisplayToolbar System ScreenStartup / System Settings OCN OCF Lang Problem Check this Possible Cause Corrective Action TroubleshootingProblem Check this Possible Cause Corrective Action Problem Check this Possible Cause Corrective Action System Maintenance Repair Parts Schedule Repair Parts

318281-000 specifications

The American Water Heater 318281-000 is a highly regarded product in the realm of residential water heating, providing a perfect blend of efficiency, reliability, and advanced technology. Designed to deliver hot water conveniently and effectively, this model is suitable for various home sizes and needs.

One of the standout features of the 318281-000 is its energy efficiency. This water heater is built to comply with stringent energy regulations, helping households reduce their utility costs without compromising on performance. It typically features a high Energy Factor (EF) rating, indicating more efficient energy use for heating water. This technology not only helps in saving on energy bills but also contributes to environmental sustainability by reducing the carbon footprint of the home.

The 318281-000 employs advanced insulation techniques that minimize heat loss, ensuring that hot water is readily available whenever needed. Its design often includes a high-quality tank with foam insulation, providing better retention of heat and, consequently, more hot water availability.

Moreover, the water heater showcases a robust build quality, often incorporating a glass-lined tank for enhanced durability and protection against corrosion. This feature extends the life of the unit and reduces the need for frequent maintenance. In addition, a sacrificial anode rod is typically included to further prevent rust and enhance tank longevity.

The installation of the American Water Heater 318281-000 is designed to be user-friendly, with flexible venting options and straightforward plumbing requirements. Many models come ready for either natural gas or propane configurations, providing homeowners with choices that suit their specific needs.

Another appealing aspect of this water heater is the availability of modern safety features. It generally includes a pressure relief valve and a temperature dial, making it easier for users to manage and maintain safe operation levels.

In conclusion, the American Water Heater 318281-000 stands out in the crowded water heating market by marrying high efficiency, advanced technology, and user-centered design. Its ability to provide a consistent hot water supply while being environmentally friendly makes it an attractive option for homes looking to upgrade or replace their existing water heating systems. With its blend of durability and smart features, this model is indeed a wise investment for those seeking longevity and efficiency in their home hot water solutions.