A.O. Smith AOSRE50100 owner manual Leakage Checkpoints

Page 10

LEAKAGE CHECKPOINTS

INSTRUCTIONS: USE THIS ILLUSTRATION AS A GUIDE WHEN CHECKING FOR SOURCES OF WATER LEAKAGE. YOU OR YOUR DEALER MAY BE ABLE TO CORRECT WHAT APPEARS TO BE A PROBLEM.

Temperature & Pressure

Relief Valve

Cover and Insulation shown removed to reveal tank top

Anode Rod

Where possible, remove or lift top cover to examine threads of fittings installed into tank for evidence of leakage. Correct fitting leaks as necessary.

Water leaks at the elements may be due to:

1.Defective element which leaks at terminals or thru flange. Replace element*.

2.Loose element/gasket leak:

(a)Screw-in type: tighten with 1 1/2" socket wrench or Part No. 21163 or 23985 wrench. If leak continues, remove element*, discard gasket and clean thread areas. Apply non-hardening Permatex No. 2 to thread areas, install new gasket and screw element into fitting until it seats. Tighten 1/2 to 3/4 turn with wrench.

(b)Flange type: tighten screws with wrench. If leak continues remove element* and discard gasket. Clean gasket seating areas and reinstall element with new gasket.

NOTE: Part No. 40000-1 scale cleaning replacement screws available where threads have become rusted or damaged, preventing tightening.

All water which appears at the heater bottom or on the surrounding floor may be caused by condensation, loose connec- tions or relief valve operation and leakage. Do not replace the heater until a full inspection of all potential leak points is made and corrective steps taken to stop the leak. Leakage from other appliances, water lines or ground seepage should also be suspected until proven otherwise.

To Open Drain

Condensation and dripping may appear on pipes when cold water temperature is low. Pipe fitting may be leaking.

Relief valve operation and leakage may be due to water expansion during heating cycle or foreign material on seat of valve. If the valve is not piped to an open drain the released water could be mistaken for a leaking heater. To check where threaded portion enters tank, insert Q-tip or similar absorbent material between jacket opening and valve to swab spud area. Remove valve* if leak is indicated and repair with pipe joint compound.

To Open Drain

Water on the side of the tank may be condensation due to the panel or insulation not being in place.

Drain valve leakage could be from the valve itself. Either correct the problem or replace the valve.* To check for leakage where threaded portion enters tank, insert Q-tip or similar absorbent material between jacket opening and valve to swab spud area. Remove valve* if leak is indicated and repair with pipe joint compound.

*Contact your dealer as it is necessary to shut off electricity and drain tank to perform procedure.

10

Image 10
Contents Electric Lowboys Uprights GET to Know Your Water HeaterPoint of USE Heaters Table Tops Installation Wiring Diagrams Operation Temperature RegulationTemperature Adjustment FillingReplacement Parts MaintenanceAnode ROD Maintenance Trouble Shooting Electric Water HeatersInstalling the Point USE Water Heater Optional Wall MountingWiring Diagrams Optional Cord SET WiringPoint of USE Water Heater Operation Temperature SettingsThermostat Adjustment ThermostatsLeakage Checkpoints Limited Residential Electric Warranty EES / Estt / ELFTH Street ALSIP, Illinois 60803 Phone 1-800-433-2545 Fax

AOSRE50100 specifications

A.O. Smith AOSRE50100 is a high-performance electric water heater designed to provide reliable hot water solutions for residential and commercial applications. This model stands out in the market due to its energy efficiency, innovative technologies, and user-friendly features, ensuring a consistent supply of hot water while optimizing energy consumption.

One of the key features of the AOSRE50100 is its impressive recovery rate. The water heater has a powerful heating element that allows it to quickly replenish hot water, making it suitable for households with high hot water demand. Whether for showers, dishwashing, or laundry, this unit can effectively meet the needs of users without prolonged waiting times.

The AOSRE50100 incorporates advanced insulation that minimizes heat loss, contributing to its overall energy efficiency. The higher the insulation level, the less energy spent maintaining the desired water temperature, making the A.O. Smith AOSRE50100 an eco-friendly choice. Its Energy Factor (EF) ratings are noteworthy, showcasing its ability to deliver significant cost savings on utility bills over time.

A.O. Smith has equipped the AOSRE50100 with smart technologies that enhance user convenience. The integrated digital display allows users to easily monitor and adjust the water temperature to their preferred settings. This feature not only provides flexibility but also enhances safety, preventing scalding risks, especially in homes with children.

Durability is another significant characteristic of the A.O. Smith AOSRE50100. Constructed with high-quality materials, this water heater is designed to withstand harsh conditions. The tank is coated with corrosion-resistant materials, extending its lifespan and ensuring longevity. A.O. Smith's commitment to quality craftsmanship also means that customers can rely on warranties that provide peace of mind.

Installation and maintenance of the AOSRE50100 are straightforward. Its compact design allows for versatile placement, making it suitable for installations in tight spaces. Furthermore, regular maintenance is simplified, with easy access to essential components, enabling homeowners to keep the unit in optimal condition effortlessly.

In summary, the A.O. Smith AOSRE50100 is a standout electric water heater that combines performance, efficiency, and convenience. With its high recovery rate, advanced insulation, smart technologies, and durable construction, it provides users with a dependable hot water solution for a modern lifestyle. Whether for residential or commercial use, the AOSRE50100 is an excellent investment for anyone seeking reliable and efficient hot water delivery.