A.O. Smith FPS40, FPSE50, fps50, FPS 75 manual AIR for Combustion cant, Conditioncausesolution

Page 18

FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK

AIR FOR COMBUSTION cant.

CONDITIONCAUSESOLUTION

Burnt gas odor when

Leaking vent

Seal vent joints

heater is operatinq

joints

 

 

Blocked vent

Clear vent blockaQe

The majority of the complaints associated with the operation of the will likely be a direct result of improper venting. If the customer complains of smelling burnt gas around the water heater, first check for vent gases that may be leaking from the PVC joints or around the area between the blower assembly and water heater. Seal all leaks with the high temperature silicone sealant provided.

Check for restrictions in the venting that may cause some spillage of burnt gas into the room and check your draft, visually inspecting the vent termination for blockage, clearing blockage as

necessary.

Improper venting is also a major cause of sooting in water heaters. If you experience sooting with the POWER SHO~, check that the inlet air damper swings freely and opens 1 1/4" when the blower is running.

If water is dripping from the blower, condensate is the culprit To correct the problem, install a condensate tee, and pipe to drain.

If the customer complains of nuisance pilot outage or pilot gas odor on standby, this may be due to a lack of combustion air, or other appliance (exhaust fans, clothes dryers, etc.) creating a backdratt in the FPS venting. In either case, install additional make-up air ducts.

@1995

 

 

A.D. Smith

Technical

Information

Water Products Co.

17

Irving, Texas

Image 18
Contents Series 226E Water ProductsCompany Workbook Introduction Table of Contents Choosing the Best Water Heater Choosing the Best Water Heater cant FPS/FPSE/FPD Technical Training and Service Workbook Venting Installation Venting Installation cant Exterior Clearances FPS FpseVenting Installation cant Exterior ClearancesFPD Venting INSTAllATION cant Venting INSTAllATION cant Venting INSTAllATION cant Venting INSTAllATION cant Venting INSTAllATION cant Venting Installation cant Venting INSTAllATION cant AIR for Combustion Conditioncausesolution AIR for Combustion cantAIR for Combustion ConditionNegative Pressure Smith Technical Information Water Products Co Irving, Texas FPS 40 and 50 Service and Operation FPS 40 and 50 Service and Operation cant ~~~FPS 40 and 50 Service and Operation cant Preliminary Checks Shooting Water Products Co Irving, Texas Results Trouble Blower does not RUN Shooting Fan Does Not run Replace Harness Run Gas pressure switch IrvinQ, Texas Trouble Ifthen FPS 40 and 50 Service and Operation cant Irving, Texas Trouble Blower Runs Constantly No main burner @1995 FPS 40 and 50 Service and Operation cant Trouble- Pilot Problems Main Burner Problems FPS 40 and 50 Parts List ~@.,~ FfiGJ1i9I7 T81917 FPS/FPSE/FPD Technical Training and Service Workbook FPS/FPSE/FPD Technical Training and Service Workbook IPage51 @1995 Smith Technical Information Water Products Co FPS/FPSE/FPD Technical Training and Service Workbook Shooting Cont Trouble Blower does not RUN cant Shooting Blower does not RUN Trouble Blower does not RUN cant @1995 Smith Technical Information Results Rt.~\-\~ Fpse 40 and 50 Service and Operation CAlliNG for HEAT, no PilOTFpse 40 and 50 Service and Operation cant Then Trouble Shooting Water Products Co Fpse 40 and 50 Service and Operation cant Results FPS/FPSE/FPD Technical Training and Service Workbook Replace Shooting Pilot Problems Trouble- Main Burner Problems Fpse 40 and 50 Parts List FPD 40 and 50 Parts List Ill @J..~~Cable.COtIlroIw/C1~ FPS 75 Service and Operation FPS 75 Service and Operation cant FPS 75 Service and Operation Trouble- Preliminary Checks FPS 75 Service and Operation cant Trouble Blower does not RUN Shooting Cont Shooting Results Preliminary Checks Exceptions Blower Runs CONSTANTLYNo call for heat Trouble- Blower Runs Constantly No call for heat cant Trouble Shooting CAlliNG for HEAT, no PilOTFPS 75 Service and Operation Line=24 VAG supply Load=Wire carrying current onto connector Water Products Co Shooting Shootingcont FPS 75 Service and Operation cant Meter does not read 24 VAC, the meter does read 24 VAG FPS 75 Service and Operation FPS 75 Service and Operation cant Water Products Co Then Shooting Trouble- PilOT Problems Main Burner Problems FPS 75 Parts List 3511FPS-75 Series 230/231 Thru 232/233 Item Description Part NumberSpecification Part InformationService Checklist Proper Sequence of OperationService Checklist cant VII. SafetyQuestions and Answers FPS ModelsQuestions and Answers cant 400 deg. FAdditional Information @c 0fiJDcu~

FPS 75, FPSE50, FPS40, fps50 specifications

A.O. Smith is a leader in water heating solutions, well-known for its innovative technologies and high-quality products. Among their extensive lineup, the FPS series, which includes the FPS40, FPS50, FPS75, and FPSE50, stands out for its efficiency and reliability. Each model is tailored to meet varying demands, making them ideal for both residential and commercial applications.

The FPS40 is a compact and efficient water heater with a capacity of 40 gallons, making it suitable for smaller households. It features an advanced electronic control system that ensures optimal temperature management, reducing energy consumption. The tank is insulated with high-density foam, which helps maintain water temperature and minimizes heat loss.

Next in the lineup is the FPS50, which offers a 50-gallon capacity. This model is designed for families that require a greater supply of hot water but still prioritize energy efficiency. The FPS50 employs a durable glass-lined tank that resists corrosion, prolonging the unit's lifespan. Additionally, it comes equipped with a self-diagnostic system that monitors and displays performance, making troubleshooting straightforward.

For those with even greater hot water needs, the FPS75 is available with a robust 75-gallon capacity. This model is engineered for larger households or light commercial use. The FPS75 features a powerful heating element that enables faster recovery rates, ensuring an ample supply of hot water. Its user-friendly digital display allows homeowners to easily adjust temperatures and settings, providing convenience and control over their system.

Finally, the FPSE50 is a hybrid model that incorporates advanced heat pump technology. This unit combines the efficiencies of a heat pump with traditional electric heating, resulting in significant energy savings. The FPSE50 is particularly appealing for energy-conscious consumers, as it offers the flexibility of operating modes, such as energy-saving mode, standard mode, and high-demand mode.

All models in the FPS series reflect A.O. Smith's commitment to quality engineering and innovation. They come with comprehensive warranties, ensuring customer satisfaction and peace of mind. With features like advanced insulation, smart diagnostics, and hybrid technology, A.O. Smith continues to lead the industry in providing efficient and reliable water heating solutions suitable for various needs and preferences.