A.O. Smith GPS-75 Selection of Materials, Primer, Cement, Applicators, Making the Joint, Step a

Page 11

2.SELECTION OF MATERIALS

Cutting Device - Saw or Pipe Cutter

Deburring Tool, Knife, File, or Beveling Machine (2" and above)

Brush - Pure Bristle

Rag - Cotton (Not Synthetic)

Primer and Cleaner

Solvent Cement - PVC for PVC Components and CPVC for CPVC Components

Containers - Metal or Glass to hold Primer and Cement. Select the type of PVC or CPVC materials to be used on the basis of their application with respect to chemical resistance, pressure rating, temperature characteristics, etc.

Insertion Tool - Helpful for larger diameter pipe and fittings (6" and above).

PRIMER

It is recommended that Tetrahydrofuran (THF) be used to prepare the surfaces of pipe and fittings for solvent welding. Do not use water, rags, gasoline or any other substitutes for cleaning PVC or CPVC Surfaces. A chemical cleaner such as MEK may be used.

CEMENT

The cement should be a bodied cement of approximately 500 to 1600 centipoise viscosity containing 10-20% (by weight) virgin PVC material solvated with tetrahydrofuran (THF). Small quantities of dimethyl formamide (DMF) may be included to act as a retarding agent to extend curing time. Select the proper cement; Schedule 40 cement should be used for Schedule 40 pipe. Never use all-purpose cements, commercial glues and adhesives or ABS cement to join PVC or CPVC pipe and fittings.

SAFETY PRECAUTION: PRIMERS AND CEMENTS ARE EXTREMELY FLAMMABLE, AND MUST NOT BE STORED OR USED NEAR HEAT OR OPEN FLAME. ALSO, USE ONLY IN A WELL-VENTILATED AREA.

APPLICATORS

Select a suitable pure bristle type paint brush. Use a proper width brush or roller to apply the primer and cement (see chart below). Speedy application of cement is important due to its fast drying characteristics. IMPORTANT NOTE: A dauber type applicator should only be used on pipe sizes 2" and below. For larger diameter pipe, a brush or roller must be used.

3.MAKING THE JOINT

A. Cutting

Pipe must be squarely cut to allow for the proper interfacing of the pipe end and the fitting socket bottom. This can be accomplished with a miter box saw or wheel type cutter. Wheel type cutters are not generally recommended for larger diameters since they tend to flare the corner of the pipe end. If this type of cutter is used, the flare on the end must be completely removed.

STEP A

NOTE: Power saws should be specifically designed to cut plastic pipe.

B.Deburring

Use a knife, plastic pipe deburring tool, or file to remove burrs from the end of small diameter pipe. Be sure to remove all burrs from around the inside as well as the outside of the pipe. A slight chamfer (bevel) of about 10°-15° should be added to the end to permit easier insertion of the pipe into the end of the fitting. Failure to chamfer the edge of the pipe may remove cement from the fitting socket, causing the joint to leak.

STEP B

C. Test dry fit of the joint

Tapered fitting sockets are designed so that an interference fit should occur when the pipe is inserted about 1/3 to 2/3 of the way into the socket. Occasionally, when pipe fitting dimensions are at the tolerance extremes, it will be possible to fully insert dry pipe to the bottom of the fitting socket. When this happens, a sufficient quantity of cement must be applied to the joint to fill the gap between the pipe and fitting. The gap must be filled to obtain a strong, leak-free joint.

D.Inspection, cleaning, priming

Visually inspect the inside of the pipe and fitting sockets and remove all dirt, grease or moisture with a clean dry rag. If wiping fails to clean the surfaces, a chemical cleaner must be used. Check for possible damage such as splits or cracks and replace if necessary.

Depth-of-entry mark

Marking the depth of entry is a way to check if the pipe has reached the bottom of the fitting socket in step F. Measure the fitting depth and mark this distance on the pipe O.D. You may want to add several inches to the distance and make a second mark as the primer and cement will most likely destroy your first one.

Apply primer to the surface of the pipe and fitting socket with a natural bristle brush (see chart). This process softens and prepares the PVC or CPVC for the solvent cementing step. Move quickly and without hesitation to the cementing procedure while the surfaces are still wet with primer.

E.Application of solvent cement

Apply the solvent cement evenly and quickly around the outside of the pipe at a width a little greater than the depth of the fitting socket.

Apply a light coat of cement evenly around the inside of the fitting socket. Avoid puddling.

Apply a second coat of cement to the pipe end.

11

Image 11
Contents Residential GAS Water Heaters GET to Know Your Water Heater Replacement Parts and Deliming ProductsImproper Combustion External DamageChemical Vapor Corrosion Extended NON-USE PeriodsInstallation Water Connections Unconfined SpaceWater Potable Heating and Space Heating Confined SpaceRelief Valve Connection of GAS PipePlanning the Vent System VentingVent Pipe Termination Condensate Installation of Vent SystemVent Terminal INSTALLATION, Sidewall Preparation of Blower AssemblyPower Vent Wiring Schematic Figure Initial Preparation Installation of Vent SYSTEM, SidewallInstallation of Vertical Vent System Vent Pipe PreparationApplicators Selection of MaterialsPrimer CementStep G OperationTo Operate the Heater Step EDo not TRY to Light the Burner by Hand What to do if YOU Smell GASTemperature Regulation MaintenanceVenting System High Temperature Limit SwitchPower Venter Maintenance Main BurnerCathodic PROTECTION-ANODE Trouble ShootingService and Repair CondensationTroubleshooting Water Heater Control LED Status Problem Solution Trouble Shooting GuideImportant Information Limited Residential GAS WarrantyConditions and Exceptions Smith Water Products CO., INC

GPS-75 specifications

The A.O. Smith GPS-75 is a state-of-the-art gas water heater designed to deliver efficient and reliable hot water solutions to residential and light commercial users. With its sleek design and advanced technology, this unit stands out in the competitive water heating market.

One of the primary features of the GPS-75 is its impressive 75-gallon capacity, making it ideal for larger households or businesses that require a substantial volume of hot water. This water heater delivers a first-hour rating of up to 91 gallons, ensuring that you will always have enough hot water on demand, even during peak usage times.

The GPS-75 utilizes a high-efficiency gas burner that operates at an energy factor of 0.67, which helps to minimize energy costs while providing robust heating performance. This means that users can enjoy powerful hot water output without having to worry about skyrocketing energy bills. Additionally, the unit is equipped with a state-of-the-art electronic ignition system that ensures reliable startup and operation. This feature eliminates the need for a pilot light, enhancing safety and energy efficiency.

In terms of durability, the GPS-75 features a glass-lined interior which protects the tank from rust and corrosion. This adds to the unit's longevity and reduces the need for maintenance and replacement. The water heater also comes with insulating foam in the tank and a special temperature and pressure relief valve to enhance safety.

Another notable technology included in the GPS-75 is its advanced diagnostics feature. This system is designed to monitor and diagnose problems, allowing for quick troubleshooting and minimizing downtime. This is especially useful for service professionals and homeowners alike, as it facilitates efficient maintenance and reduces unexpected repair costs.

The GPS-75 also has an environmentally friendly design, meeting stringent energy efficiency guidelines. This aligns with the growing demand for sustainable solutions in modern homes and businesses.

In summary, the A.O. Smith GPS-75 gas water heater combines an impressive 75-gallon capacity, high efficiency, and advanced safety features to offer users a reliable and economical hot water solution. With its innovative technologies and durable construction, it stands as a strong contender in the water heating industry. Whether for residential or commercial use, the GPS-75 ensures that hot water is always available when needed.