Linear LD 033 manual Remote controls will not operate well, To Add a Remote Control, Testing

Page 1
REMOVING ALL REMOTES
1
PRESS THE LEARN BUTTON
FOR 10 SECONDS OR MORE
REPLACING A REMOTE'S BATTERY
1
TWIST DIME IN SLOT TO OPEN CASE
3
CAREFULLY REMOVE THE CIRCUIT BOARD
4
REMOVE OLD BATTERIES AND DISPOSE OF THEM PROPERLY
- OR -
PRESS A
BUTTON
1
SEND A SIGNAL
FROM A REMOTE

PROFESSIONAL INSTALLATION BY:

MODELS LDO33 & LDO50

BELT-DRIVE OR CHAIN-DRIVE

GARAGE DOOR OPENERS

HOMEOWNER’S INSTRUCTIONS

For Sectional and Jamb Type Doors

IMPORTANT SAFETY NOTES

Please read the instructions carefully! This garage door opener is designed to provide safe and reliable service if installed and tested as described in these instructions. A garage door is the largest mechanical appliance in a residence. Care must be taken to prevent injury or death during installation and operation of the garage door and garage door opener.

THE FOLLOWING FORMATS ARE USED FOR SAFETY NOTES IN THESE INSTRUCTIONS.

2 Remote Controls

This opener is supplied with a three-button remote control (the second and third buttons can be used to control an additional operator or gate if it contains a Linear MegaCode™ receiver). Additional single and multi-button remote controls can be purchased. An unlimited number of remote controls can be used with this operator. The short white

wire on the back of the operator serves as an antenna for

PREPARING TO ADD A REMOTE

the remote controls. Do not cut off the white wire or the

 

remote controls will not operate well.

2

WARNING

LEARN LIGHT WILL

GLOW FOR 15 SECONDS

Children operating or playing with a garage

REMOTE MUST BE

door opener can injure themselves or others.

ENTERED WHILE LEARN

The garage door could cause serious injury

LIGHT IS ON

or death. Do not allow children to operate the

 

remote control(s) or the wall station. A moving

1

garage door could injure or kill someone under

PRESS THE LEARN BUTTON

it. Activate the opener only when the door

 

is clearly visible, free of obstructions and

ADDING A REMOTE

adjusted properly.

 

WARNING

CAUTION

This type of warning note is used to indicate

This type of warning note is used to indicate

possible mechanical hazards that may cause

the possibility of damage to the garage door or

serious injuries or death.

garage door opener.

IMPORTANT USER SAFETY INSTRUCTIONS

WARNING

A MOVING GARAGE DOOR CAN CAUSE INJURY OR DEATH!

TO REDUCE THE RISK OF DEATH OR SEVERE INJURY:

1READ AND FOLLOW ALL INSTRUCTIONS.

2NEVER LET CHILDREN OPERATE, OR PLAY WITH DOOR CONTROLS! KEEP REMOTE CONTROL AWAY FROM CHILDREN!

3Always keep moving door in sight and away from people and objects until it is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.

4NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.

5Test door opener monthly. The garage door MUST reverse on contact with a 1-1/2 inch object (or a 2x4 board laid flat at the center of the door) on the floor. If adjusting either the force or the limit of travel, re-test the door opener. Failure to adjust the opener properly may cause severe injury or death.

6If possible, use the red emergency release handle only when the door is closed. Use caution when using this release with the door open. Weak or broken springs may cause the door to fall rapidly, causing injury or death.

7KEEP GARAGE DOORS PROPERLY BALANCED. (See Garage Door Opener Maintenance) An improperly balanced door could cause severe injury or death. Have a qualified service person make repairs to cables, spring assembly and other hardware.

8SAVE THESE INSTRUCTIONS.

To Add a Remote Control

1Press the opener’s LEARN button. The red LEARN light will glow. The red light will stay on for about 15 seconds. A remote must be added while the red

LEARN light is still on.

2Send a signal from a remote. The red LEARN light and the opener’s light will fl ash once indicating that the opener has accepted the remote.

3Repeat Steps 1 & 2 for any additional remote controls.

To Remove all Remote Controls

1Press and hold the opener’s LEARN button for ten seconds or more.

2Release the LEARN button. The red LEARN light will blink three times signaling that all of the remotes in the opener’s memory were erased. The red LEARN light will turn off, then turn on for 15 seconds. A remote control can be entered during this time using Step 2 above.

Testing

1Before testing the remote control, straighten out the opener’s white antenna wire so it points up.

2Stand clear of the door, press the remote control’s button and verify that the opener starts.

Replacing a Remote Control’s Batteries

When the red light on the remote glows dimly, or fails to light at all when the remote is activated, the batteries need replacing.

1Open the remote’s case and remove the circuit board.

2Replace old batteries with two Type 2032 batteries.

3Re-assemble the remote.

DOWN

UP

 

 

CLOSE

LIMIT

DOWN

UP

 

 

OPEN LIMIT

2 THE OPENER'S LIGHT AND LEARN LIGHT WILL FLASH ONCE WHEN REMOTE HAS

ENTER A CODEBEEN ACCEPTED AND PRESS

START/STOP

2

THE LEARN LIGHT

WILL BLINK 3 TIMES

SIGNALING THAT

ALL REMOTES WERE

REMOVED

2

LIFT OFF

THE TOP OF

THE CASE

NOTE: THE CIRCUIT BOARD WILL FIT ONLY ONE

WAY INTO THE CASE. ALIGN THE PLASTIC POST

IN THE CASE WITH THE HOLE IN THE CIRCUIT BOARD

5

INSERT TWO NEW

TYPE 2032 BATTERIES

PLUS SIDE UP THEN

REASSEMBLE UNIT

1

Using the Garage Door Opener

OPENING OR CLOSING THE DOOR

 

Opening the Door

WALL STATION

REMOTE CONTROL

 

1

With the door in view, press the wall station’s UP/

 

 

 

 

 

DOWN ARROW button, the button assigned to the

 

 

REMOTE

 

opener on the remote control, or enter a valid access

 

 

KEYPAD

 

 

 

 

 

code and press START/STOP on a remote keypad.

 

 

 

2

When the opener is activated, the opener’s light will

 

 

 

3

turn on and the door will begin to open.

 

 

ENTER AN

The door will open until the open limit is reached. If

PRESS THE

PRESS A REMOTE

ACCESS CODE

 

an obstacle is encountered (opener’s light fl ashes four

WALL STATION'S - OR -

CONTROL BUTTON

- OR - AND PRESS

 

times) while the door is opening, the door will stop.

UP/DOWN ARROW

 

START/STOP

 

 

 

 

3 Garage Door Opener Maintenance

Weather conditions may affect the door operation which could require some re-setting of the opener’s adjustments. Doors may swell and become heavier during wet periods, door hinges and rollers might bind during cold periods. To insure safe operation of the door, perform the following tests, including any additional test steps described.

Every Month

1

With the door closed, pull the red release handle to

 

disconnect the opener from the door.

2

From outside the garage, slowly open the door

WARNING

Garage door hardware (springs, cables, brackets, pulleys, etc.) are under extreme pressure and tension. DO NOT ATTEMPT TO LOOSEN, TIGHTEN OR ADJUST ANY DOOR HARDWARE. CALL A QUALIFIED GARAGE DOOR INSTALLATION PROFESSIONAL!

WARNING

The garage door opener must not be installed and used on an unbalanced door. The opener’s internal door force sensor will not function

4The opener’s light will stay on for about fi ve minutes after the door stops.

Closing the Door

1With the door in view, press the wall station’s UP/ DOWN ARROW button or the button assigned to the opener on the remote control, or enter a valid access code and press START/STOP on a remote keypad.

2When the opener is activated, the opener’s light will turn on and the door will begin to close.

3The door will close until the close limit is reached. If an obstacle is encountered (opener’s light fl ashes four times), or the safety beam is interrupted (opener’s light fl ashes three times) during closing, the door will stop, then re-open.

4The opener’s light will stay on for about fi ve minutes after the door stops.

Stopping the Door Mid-travel

1The door can be stopped immediately at any time by pressing the wall station’s UP/DOWN ARROW button, the remote control’s pushbutton, or press the START/STOP button on a remote keypad.

2The next time the opener is activated, the door will move in the opposite direction.

Vacation Lock for Additional Security

1 Slide the wall station’s LOCK switch to the locked position to prevent remote controls from opening the door after the door is completely closed. The remotes can close the door, but not open it. The door can still be opened or closed by using the wall station’s UP/DOWN ARROW pushbutton.

NOTE: To signal that the vacation switch is locked, the opener’s light will flash five times if a remote is activated in an attempt to open the door.

2Slide the wall station’s LOCK switch to the unlocked position to return the opener to normal operation.

Controlling the Opener’s Light

1 The opener’s light can be lit by pushing the wall station’s LIGHT button. The light will remain on until the LIGHT button is pressed again or the opener is cycled.

2If the opener’s light is on, pushing the wall station’s LIGHT button will turn the opener’s light off.

Disconnecting the Door from the Opener

1 With the door in any position (preferably closed),

SAFETY LIGHTING

WHENEVER OPERATING

NOTE: A FLASHING

THE LIGHT WILL TURN ON

LIGHT INDICATES

FOR ABOUT 5 MINUTES

TROUBLE

STOPPING THE DOOR

WALL

 

 

STATION

 

REMOTE

 

KEYPAD

 

REMOTE

 

CONTROL

 

THE DOOR CAN BE STOPPED

 

AT ANY POSITION USING THE

 

WALL STATION, REMOTE CONTROL,

 

OR A REMOTE KEYPAD

PREVENTING REMOTES

FROM OPENING THE DOOR

LOCK UNLOCK

SLIDE THE VACATION SWITCH

DOWN TO LOCK (REMOTES DISABLED)

OR UP TO UNLOCK (REMOTES NORMAL)

CONTROLLING THE

OPENER'S LIGHT

PRESS THE LIGHT

THE LIGHT WILL STAY ON UNTIL

BUTTON TO TURN THE

THE LIGHT BUTTON IS PRESSED

LIGHT ON OR OFF

OR THE OPENER IS CYCLED

 

 

 

 

IN CASE OF POWER FAILURE

 

OR IF DOOR BECOMES OBSTRUCTED

manually all the way, and then close it all the way.

Notice if there is any binding, sticking or rubbing. The

door should move smoothly in both directions.

3 Raise the garage door about halfway up. Carefully

release the door and see if the door balances. It

should stay in place. Close the door.

NOTE: If the garage door is unbalanced or the door travel isn’t smooth, have a qualified garage door professional adjust or repair the door.

4To reconnect the opener, fl ip the release lever up. Raise the door manually until the opener reconnects.

5Perform the Safety Beam Test (Section 4).

6Perform the Safety Reversal System Test as described in Steps 4-6 in Section 6.

After Servicing the Opener

1Perform the Safety Beam Test (Section 4).

2Perform the Open and Close Limit Adjustments (Section 5).

3Perform the entire Door Force Safety System Test (Section 6).

Every 6 Months

Check the belt or chain tension.

For belt-drive rails, examine the length of the tension spring in the traveler. It should be about 1” long.

For chain-drive rails, examine the spacing between the turnbuckle and the rail. The turnbuckle should be slightly above the rail.

NOTE: Too much or too little chain tension will cause excessive sprocket noise.

Chain Adjustment

If necessary, use the following steps to adjust the chain.

1Hold the turnbuckle with a fl at blade screwdriver and loosen the two locknuts with a 7/16” end wrench.

2Twist the turnbuckle to adjust the chain tension. Adjust the chain until the turnbuckle is sightly above the rail.

3Hold the turnbuckle with a fl at blade screwdriver and tighten the two locknuts with a 7/16” end wrench.

Belt Adjustment

The tension spring in the traveler keeps the belt taut. The factory setting for the tension spring length is .9” long. If the tension spring is longer than 1”, adjust the belt.

1 Hold the traveler so the adjustment wheel is visible

through the large slot.

properly on an unbalanced door. Risk of serious injury or death may result.

TO DISCONNECT OPENER

TO RECONNECT OPENER

PULL THE RED

RELEASE HANDLE

TO DISCONNECT

FLIP THE LEVER UP

 

AND RAISE OR

 

THE OPENER FROM

PULL DOWN ON HANDLE

 

 

NOTICE

 

 

IF DOOR BECOMES OBSTRUCTED,

THE DOOR

 

LOWER THE DOOR

 

NOTICE

TO RECONNECT

 

 

PULL DOWN ON HANDLE

 

 

IF DOOR BECOMES OBSTRUCTED,

 

 

 

 

THE OPENER

 

CHECKING THE DOOR BALANCE

 

 

 

THE DOOR SHOULD

 

 

BALANCE WITHOUT

 

 

GOING UP OR DOWN

WARNING

Always perform the entire Door Force Safety System Test (see Section 6) after making any adjustments to the opener.

TESTING THE SAFETY REVERSAL SYSTEM

TEST WITH SMALL OBSTACLE

THE DOOR MUST REVERSE

WITHIN 2-SECONDS AFTER

IMPACT WITH A 2 x 4 BOARD

2 x 4 BOARD LAID FLAT UNDER CENTER OF DOOR

ADJUSTING A CHAIN-DRIVE

 

TWIST

 

 

 

TURNBUCKLE

TURNBUCKLE

 

CHAIN

 

 

TIGHTEN

CHAIN

LOCKNUTS

 

 

 

 

LOOSEN

LOCKNUTS

 

 

 

LOOSEN

 

 

 

 

HOLD TURNBUCKLE

 

 

TO OPENER LOCKNUTS

WITH FLAT BLADE

 

 

TIGHTEN

SCREWDRIVER TO

 

 

BACKUP LOCKNUTS

 

 

 

 

 

ADJUSTING A BELT-DRIVE

MEASURE THE TENSION

 

SPRING LENGTH

carefully pull the red release handle. USE CAUTION

IF THE DOOR IS OPEN, THE DOOR MAY DROP.

2 The disconnected door can be opened or closed manually.

3To reconnect the opener, fl ip the release lever up. Raise or lower the door manually until the opener reconnects.

PULL THE RED

 

 

RELEASE HANDLE

FLIP THE LEVER UP

 

TO DISCONNECT

 

AND RAISE OR

 

THE OPENER FROM

NOTICE

IF DOOR BECOMES OBSTRUCTED,

LOWER THE DOOR

PULL DOWN ON HANDLE

 

 

2 Use a fl at blade screwdriver to turn the adjustment

wheel to compress the tension spring until its length

is between .9” and 1” long.

Every Year

Check the door hardware for lubrication needs. Lubricate door hinges, rollers and bearings according to door

TRAVELER

ADJUSTMENT WHEEL

LOOSEN

TIGHTEN

THE DOOR

NOTICE

TO RECONNECT

 

IF DOOR BECOMES OBSTRUCTED,

 

PULL DOWN ON HANDLE

 

 

THE OPENER

manufacturer’s recommended procedures.

TURN THE ADJUSTMENT WHEEL UNTIL THE TENSION SPRING IS ABOUT 1" LONG

Image 1
Contents To Add a Remote Control Remote controls will not operate wellTo Remove all Remote Controls TestingSender and receiver should be lit Safety Beam Test

LD 033 specifications

The Linear LD 033 is a cutting-edge lighting solution that has gained popularity in various commercial and residential applications. Known for its sleek design and versatility, it seamlessly combines aesthetics with functionality, making it an excellent choice for those seeking an efficient lighting option.

One of the main features of the Linear LD 033 is its energy efficiency. Utilizing advanced LED technology, this lighting fixture consumes significantly less power compared to traditional lighting solutions, resulting in lower energy bills and a reduced carbon footprint. With an exceptional luminous efficacy, the LD 033 provides bright illumination while minimizing energy waste.

The LD 033 also boasts a high lumen output, ensuring that spaces are well-lit without the need for multiple fixtures. This makes it particularly suitable for large areas such as warehouses, retail environments, and office spaces. The even distribution of light enhances visibility and safety while contributing to an inviting atmosphere.

In terms of design, the Linear LD 033 incorporates a streamlined profile that fits various architectural styles. Its low-profile design allows for easy integration into ceilings, walls, and various structures. Additionally, it is available in various lengths and configurations, allowing for customized lighting solutions tailored to specific needs.

The fixture is built with durability in mind, featuring a robust housing that can withstand various environmental conditions. Its IP rating ensures protection against dust and moisture, making the Linear LD 033 suitable for both indoor and outdoor applications. This resilience means it can function reliably even in demanding settings.

Moreover, the Linear LD 033 is compatible with modern smart lighting systems. This functionality allows users to control the lighting remotely, adjust brightness, and create lighting schedules, enhancing convenience and energy savings. Integration with smart home systems is straightforward, making it an ideal choice for tech-savvy users.

The installation process is straightforward, thanks to the fixture's lightweight and modular design. It can be mounted in several orientations, providing flexibility in installation orientation while ensuring optimal performance. Maintenance is also simplified, as the long lifespan of the LEDs reduces the need for frequent replacements.

In conclusion, the Linear LD 033 stands out in the market due to its energy efficiency, high lumen output, customizable design, durability, and compatibility with smart technologies. Whether for commercial or residential use, this linear lighting solution meets the demands of diverse environments while enhancing the overall experience through quality illumination.