Chamberlain 311 Test the Safety Reversal System, Test the Protector System®, TEST, must, ADJUST, IMPORTANT SAFETY CHECK:

Page 30

30

Without a properly installed safety reversal system,

persons (particularly small children) could be

SERIOUSLY INJURED or KILLED by a closing garage

door. 

• Safety reversal system MUST be tested every month.

• If one control (force or travel limits) is adjusted, the

other control may also need adjustment.

• After ANY adjustments are made, the safety reversal

system MUST be tested. Door MUST reverse on

contact with 1-1/2" (3.8 cm) high object (or 2x4 laid

flat) on the floor.

ADJUSTMENT STEP 3

Test the Safety Reversal System

TEST

• With the door fully open, place a 1-1/2" (3.8 cm)

board (or a 2x4 laid flat) on the floor, centered

under the garage door.

• Operate the door in the down direction. The door

must reverse on striking the obstruction.

ADJUST

• If the door stops on the obstruction, it is not

traveling far enough in the down direction.

Increase the DOWN limit by turning the DOWN

limit adjustment screw counterclockwise 1/4 turn.

NOTE: On a sectional door, make sure limit

adjustments do not force the door arm beyond a

straight up and down position. See the illustration

on page 28.

• Repeat the test.

• When the door reverses on the 1-1/2" (3.8 cm)

board, remove the obstruction and run the opener

through 3 or 4 complete travel cycles to test

adjustment.

IMPORTANT SAFETY CHECK:

Repeat Adjustment Steps 1, 2 and 3 after:

• Each adjustment of door arm length, limits, or

force controls.

• Any repair to or adjustment of the garage door

(including springs and hardware).

• Any repair to or buckling of the garage floor.

• Any repair to or adjustment of the opener.

ADJUSTMENT STEP 4

Test the Protector System

®

• Press the remote control push button to open the

door.

• Place the opener carton in the path of the door.

• Press the remote control push button to close the

door. The door will not move more than an inch,

and the opener lights will flash.

The garage door opener will not close from a remote

if the indicator light in either sensor is off (alerting

you to the fact that the sensor is misaligned or

obstructed).

If the opener closes the door when the safety

reversing sensor is obstructed (and the sensors

are no more than 6" (15 cm) above the floor), call

for a trained door systems technician.

Safety Re

v

ersing Sensor

Safety Re

v

ersing Sensor

Without a properly installed safety reversing sensor,

persons (particularly small children) could be

SERIOUSLY INJURED or KILLED by a closing garage

door. 

1-1/2" (3.

8

 cm) 

b

oard  

(or a 2x4 laid flat) 

WARNING

CAUTION

WARNING

WARNING

WARNING

CAUTION

WARNING

WARNING

Image 30