Chamberlain 311 Planning, SECTIONAL DOOR INSTALLATION, SECTIONAL DOOR INSTALLATIONS

Page 4

Planning

• Do you have an access door in addition to the

garage door? If not, Model 1702LM Outside Quick

Release is required. See Accessories page.

• Look at the garage door where it meets the floor.

Any gap between the floor and the bottom of the

door must not exceed 1/4" (6 mm). Otherwise, the

safety reversal system may not work properly. See

Adjustment Step 3. Floor or door should be

repaired.

Identify the type and height of your garage door.

Survey your garage area to see if any of the

conditions below apply to your installation. Additional

materials may be required. You may find it helpful to

refer back to this page and the accompanying

illustrations as you proceed with the installation of

your opener.

Depending on your requirements, there are several

installation steps which may call for materials or

hardware not included in the carton.

• Installation Step 1 – Look at the wall or ceiling

above the garage door. The header bracket must

be securely fastened to structural supports.

• Installation Step 5 – Do you have a finished ceiling

in your garage? If so, a support bracket and

additional fastening hardware may be required.

• Installation Step 10 – Depending upon garage

construction, extension brackets or wood blocks

may be needed to install sensors.

• Installation Step 10 – Alternate floor mounting of

the safety reversing sensor will require hardware

not provided.

SECTIONAL DOOR INSTALLATIONS

• Do you have a steel, aluminum, fiberglass or glass

panel door? If so, horizontal and vertical

reinforcement is required (Installation Step 11).

• The opener should be installed above the center of

the door. If there is a torsion spring or center

bearing plate in the way of the header bracket, it

may be installed within 4 feet (1.22 m) to the left or

right of the door center. See Installation Steps 1

and 11.

• If your door is more than 7 feet (2.13 m) high, see

rail extension kits listed on Accessories page.

SECTIONAL DOOR INSTALLATION

Horizontal and vertical reinforcement

is needed for lightweight garage doors

(fiberglass, steel, aluminum, door with

glass panels, etc.). See page 24 for details.

FINISHED CEILING

Support bracket &

fastening hardware

is required.

See page 17.

Slack in chain tension

is normal when

garage door is closed

Header Wall

Torsion

Spring

OR

Extension

Spring

— — —

Wall-

mounted

Door

Control

Access

Door

Vertical

Centerline

of Garage Door

— — —

Header

Bracket

Trolley

Garage

Door

Spring

— —

Safety Reversing Sensor

CLOSED POSITION

Idler Pulley

Bracket

Straight

Door

Arm

Safety Reversing Sensor

Gap between floor

and bottom of door

must not exceed 1/4" (6 mm).

Header

Wall

Garage

Door

4

Curved

Door

Arm

Door Bracket

Emergency

Release

Rope & Handle

Image 4