Maintenance
To prevent serious injury
from accidental operation:
Unplug the Pump from its electrical outlet before performing any inspection, maintenance, or cleaning procedures.
If the pump is moved during op- eration, flush it out with clean water after every use.
Quarterly Maintenance
The below maintenance must be per- formed at least once every 3 months under optimal conditions. For frequent use, or dirty areas, more frequent maintenance is required.
1.Clean sludge and debris from the bot- tom of the shaft.
2.Rinse the housing off with clean wa- ter.
3.Clean fibers from inside the pump housing with a pressure washer (not included).
4.If the pump housing cannot be cleaned from the outside, it must be thoroughly cleaned. Make sure the power cord is unplugged before maintenance. Dismantle the bottom part of the pump as follows:
IMPELLER FIGURE B (14)
FILTER
(11)
a. Remove the Filter (11) from the pump case.
b. Clean the impeller with clean water.
c. To prevent damage, do not rest the pump on the impeller or pry against the impeller.
d. Reassemble in reverse order.
SKU 98342 | For technical questions, please call | Page 4 |