Specifications

Model P227-3100/5100

1750 RPM+

U.S.

(Metric)

 

 

Ratings

2.1 GPM @ 2000 PSI

(8.0 LPM @ 137 bar)

3450 RPM+

 

 

Ratings

3.8 GPM @ 2000 PSI

(14.4 LPM @ 137 bar)

Inlet Pressure

-4.35 to 140 PSI

(-0.3 to 10 bar)

RPM

Up to 3450 RPM

Plunger Diameter

0.71”

18mm

Stroke

0.25”

6.3mm

Temperature of Pumped Fluids

Up to 160o F

(71oC)

Inlet Ports

(2) 3/8" BSP

Discharge Ports

(2) 3/8" BSP

Shaft Rotation

Top of Pulley Towards Fluid End

Crankshaft Diameter

24mm

Key Width

8mm

Shaft Mounting

Right Side Facing Manifold

Weight

11 lbs. 11oz

(5 kg)

Crankcase Oil Capacity

7.5 fl.oz

(0.2 liter)

Extended Crankcase Oil Capacity

9.0 fl.oz

(0.3 liter)

Volumetric Efficiency @ 1750 RPM

0.95

Volumetric Efficiency @ 3450 RPM

0.87

Mechanical Efficiency @ 3450 RPM

0.86

+Positive inlet pressure required

 

 

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

NOTE:

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P227-3100/5100 HORSEPOWER

REQUIREMENTS

RPM

GPM

1000 PSI

1500 PSI

2000 PSI

250

0.3

0.2

0.3

0.4

500

0.6

0.4

0.6

0.8

1000

1.2

0.8

1.2

1.7

1450

1.7

1.2

1.8

2.4

1750

2.1

1.4

2.2

2.9

3000

3.3

2.3

3.4

4.6

3200

3.5

2.4

3.6

4.9

3450

3.8

2.6

3.9

5.2

HORSEPOWER RATINGS: The rating shown are the power

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

HP = (GPM X PSI) / 1450

8

Image 8
Contents P200A-3100/5100 Important Operating Conditions Use Giant recommened OilSpecifications Model P217A-3100/5100 Pulley Information Horsepower InformationRPM + Metric RPM +Specifications Model P218A-3100/5100 Pulley Information Specifications Model P219A-3100/5100 Specifications Model P220A-3100/5100 Specifications Model P221A-3100/5100 Horsepower Ratings1750 RPM+ Metric 3450 RPM+Specifications Model P227-3100/5100 Horsepower Ratings The rating shown are the powerSpecifications Model P230-3100/5100 Exploded View P200A-3100/5100 Series P200A-3100/5100 Series Parts List Repair Instruction P200A-3100/5100 Series Pump Mounting Selection Guide Pump System Malfunction P200A-3100/5100 Dimensions Inches mm Giant Industries Limited Warranty