Hitachi 222104 important safety instructions Installation, Key

Page 5

Installation

 

A

 

 

A

Main Air Line

 

 

 

 

 

 

 

 

 

 

 

 

Main Fluid Line

 

C

D

E

F

B C D

E F

 

B

 

 

 

 

 

 

 

 

P

 

P

 

 

 

 

 

 

 

 

 

 

 

Q

28

 

Q

G

 

 

G

 

 

 

 

 

H

 

H

 

 

 

 

R

N

 

 

 

R

N

 

 

 

 

 

 

 

J

 

 

 

 

 

 

K

 

 

M

 

 

 

 

 

 

 

 

 

L

 

 

 

KEY

A

Air shutoff valve

J

Wall bracket

B

Air filter

K

Universal pump (Model 222051)

C

Air regulator and gauge

L

Suction kit

D

Air motor lubricator

M

55-gallon drum bung-mount pump (Model 222103)

E

Bleed-type master air valve (required, Part No. 110223)

N

Fluid drain valve (required, Part No. 210658)

F

Air and fluid hose kits

P

Air inlet

G

Ground wire (required, Part No. 222011)

Q

Ball valve (for releasing collected moisture)

H

Fluid shutoff valve

R

Thermal relief kit (required for permanent

 

 

 

 

installations, Part No. 237601)

 

 

 

28

Bung adapter

 

 

 

 

05942B

Fig. 1

 

 

 

 

 

 

 

 

 

 

 

 

Install the accessories in the order shown in the typical installation in Fig. 1. The installation shown in Fig. 1 is only a guide for selecting and installing a pump; it is not an actual system design. Contact your Graco representative for assistance in designing a system to suit your needs.

NOTE: Blow out all lines with compressed air before you connect the pumps.

CAUTION

Always mount the pump firmly to a wall bracket or a bung on a drum. Never operate the pump while it is not mounted. Such use could damage the pump and fittings.

CAUTION

Do not hang the air accessories directly on the air inlet (P). The fittings are not strong enough to support the accessories and may break. Provide a bracket on which to mount the accessories.

307906 5

Image 5
Contents See page 2 for Table of Contents Instructions Parts ListImportant Safety instructions Symbols Table of ContentsSkin Injection Hazard Fire and Explosion Hazard KEY InstallationGrounding System AccessoriesInstallation To Start the Pump OperationProblem Cause Solution TroubleshootingDisplacement Pump ServiceIntake Valve Relieve the pressurePiston Detail Description Qty Parts List15c 15d 15a 15e 15b 15f 15g 19a 19b 19c Parts DrawingTechnical Data Dimensional DrawingFluid FLOW--gpm lpm Performance CurvesToll Free Graco Standard WarrantyGraco Information