Installation
| A |
|
| A | Main Air Line |
|
|
|
|
|
|
| |
|
|
|
|
| Main Fluid Line |
|
C | D | E | F | B C D | E F |
|
B |
|
|
|
|
| |
|
|
| P |
| P |
|
|
|
|
|
|
| |
|
|
|
| Q | 28 |
|
Q | G |
|
| G |
| |
|
|
|
| H |
| H |
|
|
|
| R | N | |
|
|
| R | N | ||
|
|
|
| |||
|
|
| J |
|
|
|
|
|
| K |
|
| M |
|
|
|
|
|
| |
|
|
| L |
|
|
|
KEY
A | Air shutoff valve | J | Wall bracket | |
B | Air filter | K | Universal pump (Model 222051) | |
C | Air regulator and gauge | L | Suction kit | |
D | Air motor lubricator | M | ||
E | N | Fluid drain valve (required, Part No. 210658) | ||
F | Air and fluid hose kits | P | Air inlet | |
G | Ground wire (required, Part No. 222011) | Q | Ball valve (for releasing collected moisture) | |
H | Fluid shutoff valve | R | Thermal relief kit (required for permanent | |
|
|
|
| installations, Part No. 237601) |
|
|
| 28 | Bung adapter |
|
|
|
| 05942B |
Fig. 1 |
|
|
| |
|
|
|
| |
|
|
|
|
|
Install the accessories in the order shown in the typical installation in Fig. 1. The installation shown in Fig. 1 is only a guide for selecting and installing a pump; it is not an actual system design. Contact your Graco representative for assistance in designing a system to suit your needs.
NOTE: Blow out all lines with compressed air before you connect the pumps.
CAUTION
Always mount the pump firmly to a wall bracket or a bung on a drum. Never operate the pump while it is not mounted. Such use could damage the pump and fittings.
CAUTION
Do not hang the air accessories directly on the air inlet (P). The fittings are not strong enough to support the accessories and may break. Provide a bracket on which to mount the accessories.
307906 5