Amtrol DC2 manual Installation Instructions, Electrical Connection, Plumbing Connection

Page 2

INSTALLATION INSTRUCTIONS

Unit Must be Installed by a Qualified Professional

PLUMBING CONNECTION

1.Select a location for the DC2. The DC2 should be mounted near the pressure tank or pump, depending upon the installation

Locate the DC2 following all local codes. Do not locate the unit where it can be affected by flooding.

2.You may assemble the DC2 to a “Tank Tee” or “Tank Cross” (Figure 1) or adapt the unit to an in-line pipe fitting (Figure 2). Use Teflon sealing tape or pipe sealant. Tighten the DC2 using the wrench flats provided on the bottom connection. DO NOT EXCEED 15LB./FT. of torque.

Note: Do not allow pipe sealant or other contaminants to enter the small port in the DC2 connection.

Note: A mechanical pressure gauge is not required. Use the appropriate plug to block any unused ports.

Fig. 1

DC2

 

 

 

 

 

Pipe Nipple

Plug

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relief Valve

Drain

 

 

Valve

 

 

INSTALLATION ON TYPICAL TANK TEE

Fig. 2

DC2

Pipe Nipple

Adapt as necessary

Tee

GENERAL IN-LINE INSTALLATION

Relief Valve

ELECTRICAL CONNECTION

ELECTROCUTION HAZARD. FIRST DISCONNECT ALL ELECTRICAL POWER BEFORE SERVICING.

ELECTROCUTION HAZARD. THE DC2 MUST BE ELECTRICALLY GROUNDED.

NOTE: The DC2 will operate on 115 VAC & 230 VAC systems. Its ambient air temperature rating is 122°F / 50°C.

1.Disconnect power and verify with a volt meter.

2.Determine the pump electrical requirements. If unknown, contact the pump manufacturer.

3.Select the appropriate wire gauge per local codes and the pump manufacturer’s recommendation.

2

Image 2
Contents Installer Leave this Manual with the Owner Model DC2Plumbing Connection Installation InstructionsElectrical Connection Basic Wiring Unit Must not be Supported Solely by the Electrical ConduitOperation Device Adjustment Entering Programming ModeStart UP Error Code Reason Action Solution TroubleshootingProblem Cause Solution Explosion or Rupture HAZARD. a relief valve must be General Safety InformationRead Carefully the Product INSTALLATION, Operating Page Amtrol INC -YEAR Limited Product Warranty What is covered by this Warranty?

DC2 specifications

The Amtrol DC2 is a standout solution in the realm of water heating technology, designed to enhance both efficiency and performance for residential and commercial applications. With its robust design, the DC2 model is tailored to meet the needs of users looking for reliable hot water solutions without sacrificing energy efficiency.

At the core of the Amtrol DC2 is its advanced heating technology, which combines a high-efficiency gas burner with state-of-the-art insulation methods. This design not only ensures rapid heating but also minimizes heat loss, contributing significantly to energy savings. The Amtrol DC2 boasts an impressive recovery rate, meaning that it can deliver a steady supply of hot water on demand, making it an ideal choice for busy households or commercial settings.

One of the main features of the DC2 is its intuitive control system. The digital display allows users to monitor and adjust settings with ease, enabling precise temperature control. This feature ensures that water is heated only to the desired temperature, thereby reducing unnecessary energy expenditure. Additionally, the system includes an innovative safety shut-off mechanism, providing peace of mind to users.

The Amtrol DC2 is designed with user comfort in mind. Its relatively compact size makes installation straightforward, even in confined spaces, without compromising on performance. The durable construction materials used in the DC2 add to its longevity and less frequent need for maintenance, offering a solid return on investment.

Another key characteristic of the DC2 is its eco-friendly design. With a focus on reducing carbon footprints, the unit employs technologies that limit harmful emissions, aligning with current environmental standards and regulations. This commitment to sustainability also resonates with environmentally conscious consumers.

Overall, the Amtrol DC2 emerges as a reliable choice for those seeking a blend of performance, efficiency, and user-friendly features. Its innovative technologies and solid construction make it an attractive option for anyone in need of an effective water heating solution, offering a perfect mix of cost-effectiveness and reliability for both residential and commercial users.