Troubleshooting
Reduced spray or no spray |
|
Possible Causes | Remedies |
WARNING:
To reduce the risk of fire, electric shock or injury unplug from outlet before servicing.
Clean Water Tank Assembly empty | Refill Tank |
Spray Nozzle clogged | Clean Spray Nozzle |
Pump not operating properly | Check electrical plug |
| Power switch on? |
| Turn POWERSTEAMER® off and hold |
| Trigger for |
| Switch to“CLEAN” position and hold |
| trigger |
| Call BISSELL Consumer Services |
Vacuum not picking up cleaning solution
Possible Causes | Remedies |
Loose Triangle Cap | Check cap and snap securely into Dirty |
| Water Tank Assembly |
Dirty Water Tank Assembly | Check Tank for proper alignment and |
not aligned/secured | secure with side latches |
Flex Hose Assembly not secure | Check fit of Hose at Vacuum Port |
| connections |
Poor Tool position | Adjust angle; apply more downward |
| pressure |
Dirty Water Tank Assembly is full | Empty Dirty Water Tank Assembly |