Start-Up Procedure

1.Check air pressure in the storage tank, Refer to Storage Tank Installation. (page 6)

2.Close all water valves (5) in the system. (page 4)

3.Open water supply valve at the connection to the main water feed and the inlet water valve at the unit. If manual bypass is installed it should be in the filter position.

4.Plug in transformer.

5.Plug bypass solenoid into the filter system.

6.Open the drain/sample valve. This will purge the air from the system. When you see a steady stream of water close the drain/sample valve.

7.Open the ball valve on the storage tank.

8.Inspect all connections, fittings in the system for leaks, repair as necessary.

9.Allow storage tank to fill with RO water. NOTE: see chart for required times to fill storage tanks.

10.Open valve in water line to service and flush feed lines to each point of use.

11.System is now ready to use.

Tank Capacity

Time Required

To Fill Tank

 

2.5 gal. (9.5 lit.)

0.4 - 0.5 hour

5 gal. (19 lit.)

0.9 - 1.1 hours

10 gal. (38 lit.)

1.8 - 2.1 hours

20 gal. (76 lit.)

3.6 - 4.2 hours

40 gal. (151 lit.)

7.2 - 8.4 hours

@ 70°F (21°C) Water Temperature

Routine Maintenance

CAUTION

To reduce the risk associated with property damage due to water leakage:

Installation must comply with existing state or local plumbing codes;

Read and follow Use Instructions before installation and use of this system.

De-pressurization Procedure

1.Turn off the inlet water valve.

2.Close the tank ball valve.

3.Open the drain line valve.

4.Wait for 30 seconds, then unplug the transformer. System is now de-pressurized.

Caution: Tank will still be under pressure.

Sediment Filter (S)

Replacement Procedure [6-12 months]

1.De-pressurize the system as instructed above.

2.Locate the sediment filter. To remove the sediment filter, turn to the left 1/4 turn. Pull down to remove and discard it.

3.Insert the new filter by aligning the tabs with the filter head. Push up to insert and turn to the right 1/4 turn.

Chlorine Reduction Filter (C)

Replacement Procedure [6-12 months]

1.De-pressurize the system as instructed above.

2.Locate the chlorine reduction filter. To remove the chlorine reduction filter, turn to the left 1/4 turn. Pull down to remove and discard it.

3.Insert the new filter by aligning the tabs with the filter head. Push up to insert and turn to the right 1/4 turn.

7

Image 8
Contents STM150 TSR150 Important Notes Contents Important Installation Requirements Space RequirementFeedwater Parameters Electrical RequirementsAdditional Plumbing Manual BypassDrain Line Pressure GaugeInstallation Procedure Positioning EquipmentWall Mounting the Filter System Feedwater ConnectionStorage Tank Installation Drain ConnectionAutomatic Bypass Valve Point-of-Use ConnectionsStart-Up Procedure Routine MaintenanceDe-pressurization Procedure Sediment Filter S Replacement Procedure 6-12 monthsTDS Reduction Filter M Replacement Procedure annually Restarting and Purging the RO System‘Push-In’ Tubing Connector John Guest Fitting ScaleGard Plus 2 Electrical Wiring DiagramInstallation Components for ScaleGard Plus 2 Systems ScaleGard Plus 2 System Part List Item # Description STM150 TSR150-2 TSR150-4Limited Two Year Warranty Cuno Incorporated

TSR150, STM150 specifications

3M, a global leader in innovation and technology, has developed a range of solutions for various industries, including bonding, sealing, and fastening products. Among these, the 3M STM150 and TSR150 stand out as remarkable offerings focused on providing exceptional performance in the realm of adhesive technologies.

The 3M STM150 is a versatile safety tape that excels in providing high visibility in various environments. With a bright yellow color, it is designed to enhance awareness and improve safety in workplaces, especially in areas where there is foot traffic. The STM150 is equipped with a pressure-sensitive adhesive that allows for easy application on multiple surfaces. This product is not only durable but also water-resistant, making it suitable for both indoor and outdoor use. Its high-friction surface helps to reduce slip hazards, especially in industrial settings where safety is a top priority.

On the other hand, the 3M TSR150 is an advanced tape designed specifically for temperature-sensitive applications. One of its key features is its high-performance adhesive that remains strong even in challenging conditions. The TSR150 is particularly effective in environments that experience extreme temperatures, ensuring reliable bonding without compromising integrity. The tape is engineered to provide excellent dimensional stability and flexibility, allowing it to conform to various surfaces and shapes. This makes the TSR150 an ideal choice for automotive, aerospace, and electronics applications where precision and reliability are paramount.

Both the STM150 and TSR150 utilize 3M’s proprietary technologies, including advanced adhesive formulations and robust backing materials that enhance their performance. The tapes are designed to withstand environmental stressors such as moisture, UV rays, and chemicals, ensuring longevity and reliability in various applications.

In summary, the 3M STM150 and TSR150 are two distinctive products that showcase 3M's commitment to innovation and quality in adhesive solutions. The STM150 enhances safety through high visibility and slip resistance, while the TSR150 offers exceptional performance in temperature-sensitive environments. Each product embodies the advanced technologies and characteristics that 3M is renowned for, making them valuable tools in enhancing safety and efficiency across numerous industries.