Delta 501 Series, 520 Series, 522 Series manual Pop-Ups with Metal Flange and Plastic Tail Piece

Page 7

4

A.

1

3

2

4

D.

3

2

6

B.

 

E

 

N

 

O

 

IC

 

L

 

I

 

S

 

5

 

E.

 

1

 

 

8

 

7

9

10

C.

5

3

2

4

F.

12

11

8

Pop-Ups with Metal Flange and Plastic Tail Piece

A.

Remove stopper (1), brass nut & washer

D.

With pivot (6) facing toward faucet, pull

 

(2), black gasket (3) and tail piece (4).

 

pop-up straight down into drain hole and secure

 

 

 

gasket (3), brass nut and washer

 

Apply silicone to underside of flange (5). In-

 

(2). DO NOT TURN P OP-UP WHILE TIGHT-

B.

 

 

sert flange into sink.

 

ENING B RASS NUT OR S EALANT MAY

 

Install black gasket (3), washer and brass nut

 

NOT SEAL DRAIN. Remove excess sealant.

C.

 

 

 

 

(2) onto flange (5) from below sink but do not

 

 

 

tighten brass nut (2). Screw on tail piece (4)

 

 

 

and hand tighten.

 

 

E.Remove pivot nut (7). Install horizontal rod (8) and stopper (1) as removable

(9) or non-removable (10). Hand tighten pivot nut (7).

F.Attach horizontal rod (8) to strap (11) using clip (8). Install lift rod (12), tighten screw (11). Connect assembly to drain.

Drenajes automáticos con brida de metal y la pieza de cola plástica

A.Quite el tapón (1), la tuerca de bronce y la arandela (2), el empaque negro (3) y la pieza de cola (4).

B.Aplique silicón por debajo de la brida (5). In- troduzca la brida dentro del lavamanos.

C.Instale el empaque negro (3), la arandela y la tuerca de bronce (2) en la brida (5) desde la parte interior del lavamanos pero no apriete la tuerca de bronce (2). Atornille la pieza de cola (4) y apriete a mano.

D.Con el pivote (6) de frente a la llave, hale el desagüe automático directamente hacia abajo dentro del drenaje y fije el empaque (3), la tuerca de bronce y la arandela (2).

NO GI RE E L DREN AJE AUTOMÁTICO MIENTRAS APR IETE L A TUE RCA D E BRONCE O EL SE LLADOR P UEDA NO SELLAR EL DR ENAJE. Qu ite el exceso de sellador.

E.Quite la tuerca del pivote (7). Instale la barra horizontal (8) y el tapón (1) como desmontable (9) o fijo (10). Apriete a mano la tuerca del pivote (7).

F.Una la barra horizontal (8) a la barra chata (11) utilizando el gancho (8). Instale la barra de alzar (12), apriete

el tornillo (11). Conecte el ensamble al desagüe.

Renvoi mécanique avec collerette en métal et raccord droit de vidange en plastique

A.Enlevez la bonde (1), l’écrou en laiton et la rondelle (2), le joint noir (3) et le raccord droit de vidange (4).

B.Appliquez de composé à la silicone sous la collerette (5). Introduisez la collerette dans l’évier.

C.Montez le joint noir (3), la rondelle et l’écrou en laiton (2) sur la collerette (5) par dessous l’évier sans serrer l’écrou

en laiton (2). Vissez le raccord droit de vidange (4) et serrez-le à la main.

D.Alors que le pivot (6) fait face au robinet, tirez le renvoi directement vers le bas dans l’orifice de l’évier, puis fixez le joint (3), l’écrou en laiton et la rondelle (2). NE TOURNEZ PAS LE RENVOI PENDANT QUE VOUS SERREZ L’ÉCROU EN LAITON CAR LE COMPOSÉ À LA SILICONE POURRA NE PAS ASSURER L’ÉTANCHÉITÉ DU RENVOI. Enlevez l’excès de composé d’étanchéité.

E.Enlevez l’écrou du pivot (7). Installez la tige horizontale (8) et la bonde (1) de manière que la bonde soit amovible (9) ou non amovible (10). Serrez l’écrou (7) du pivot à la main.

F.Fixez la tige horizontale (8) au feuillard

(11)à l’aide de l’agrafe (8). Installez la tige de manoeuvre (12) et serrez la vis

(11).Fixez l’ensemble au renvoi.

53915 Rev. A

7

Image 7
Contents Asme A112.18.1 / CSA B125.1 Court À UNE PoignéeUnited States Canada Masco Corporation of IndianaMasco Corporación de Indiana Division de Masco Indiana Ev. a504, 524 Series/Series/Seria 500, 501, 520 Series/Series/Seria505, 525 Series/Series/Seria 502, 503, 522 Series/Series/SeriaRP27575 Metal Pop-Up Assembly Less Lift RodD528, D529 Series/Series/Seria RP2653313 mm IPS Do not Twist Metal Pop-UpDesagüe Automático de Metal Renvoi Mécanique en MétalDo not Turn P OP-UP While Tight Pop-Ups with Metal Flange and Plastic Tail PieceEning B Rass NUT or S Ealant MAY If faucet leaks from spout outlet-SHUT If faucet leaks from under handleIf leak persists-SHUT OFF Water If faucet leaks from spout outlet-SHUT OFF

504 Series, D528 Series, 505 Series, 501 Series, 502 Series specifications

The Delta 524 Series, 520 Series, 505 Series, D528 Series, and 522 Series represent a broad spectrum of advanced equipment and technologies designed to enhance both performance and efficiency in various applications. These product lines showcase the commitment of Delta, a global leader in power and thermal management solutions, to innovation and excellence.

Starting with the Delta 524 Series, this lineup is particularly noted for its robust and compact design, making it ideal for industrial automation and control applications. Key features include high input voltage tolerance, reliability in extreme conditions, and energy-saving capabilities. The embedded communication protocols enhance integration into complex systems, allowing for seamless connectivity and ease of use in real-time monitoring.

The 520 Series builds on the principles of efficiency and functionality. Designed for renewable energy applications, this series incorporates advanced photovoltaic technologies that maximize energy harvesting. Features such as MPPT (Maximum Power Point Tracking) technology ensure optimal energy conversion, while their lightweight design allows for simplified installation. The user-friendly interface further enhances operational efficiency, making it accessible to a wide range of users.

The Delta 505 Series is engineered with a focus on universal application compatibility. This versatility is a hallmark of the series, which offers various configurations tailored to meet specific requirements, whether in telecommunications or data centers. Notable for its high power density and low total harmonic distortion (THD), the 505 Series is designed to ensure reliable power delivery, minimizing any disruptions in critical operations.

Moving to the D528 Series, this line is renowned for its cutting-edge cooling solutions. Featuring advanced thermal management technologies, the D528 Series is essential for industries that demand precision temperature control. Enhanced airflow designs and energy-efficient components help maintain optimal conditions, thereby improving equipment lifespan and performance.

Lastly, the 522 Series is characterized by its intelligent control features, integrating IoT capabilities that allow for real-time data collection and remote monitoring. This series is particularly appealing in scenarios requiring smart grid management, offering flexibility and scalability in energy management systems.

Overall, the Delta 524, 520, 505, D528, and 522 Series symbolize the future of energy efficiency and control, reflecting the ongoing evolution of technology within industrial and commercial sectors. Each series presents unique features that cater to diverse needs, from renewable energy solutions to advanced cooling technologies, all aimed at enhancing operational efficiency and sustainability.