Mitsubishi Electronics MCFZ-A12WV FEEL... Auto Operation, Description of I FEEL... mode

Page 6
TOO
WARM

I FEEL... AUTO OPERATION

With the “ (I FEEL...)” auto operation mode, the optimum room condition can be set automatically with a one-touch operation.

Description of “I FEEL...” mode

Details of operation

˚C

CLOCK

AMPM

12345

AMPM

ON/OFF TOO TOO

WARM COOL

 

FAN

STOP

I FEEL

 

HEAT

AUTO

 

 

VANE

START

DRY

COOL

 

MODE

HR.

ECONO COOL

MIN.

 

RESET CLOCK

 

To start operation:

Press the

ON/OFF

button.

When the “ (I FEEL...)” mode is selected, the air conditioner is automatically controlled at the optimum temperature.

To stop operation:

Press the

ON/OFF

button.

If you feel slightly warm:

Press the button to lower the temperature.

One press lowers the temperature by about 1°C.

If you feel slightly cool:

According to the room temperature when the operation starts, the operation mode is automatically set to COOL, DRY or HEAT. However, when operation is started again within 2 hours after it is stopped, the same operation mode before the

operation is stopped is selected. The operation mode selected first is not changed even if the room temperature changes. If the operation mode does not match the room condition, select the appropriate operation mode by pressing the MODE

button.

Details of auto operation

Room temperature

Operation mode

Target temperature

when started

 

(initial state)

About 25°C or higher

COOL

About 24°C

 

 

 

About 25°C to 23°C

DRY

 

 

 

About 23°C or lower

HEAT

About 26°C

 

 

 

NOTE:

COOL: When the room temperature is 2°C higher than the set temperature, the set temperature may not be changed since the air conditioner is operating to reach the target (set) temperature. In this case, please wait until the room temperature drops to within 2°C of the set temperature and then change the set

TOO

Press the COOL button to raise the temperature.

One press raises the temperature by about 1°C.

temperature.

HEAT: When the room temperature is 2°C lower than the set temperature, the set temperature may not be changed since the air conditioner is operating to reach the target (set) temperature. In this case, please wait until the room temperature rises to within 2°C of the set temperature and then change the set temperature.

MODE

When “ (I FEEL...)” is not selected, press the button until it is set.

Each time the button is pressed, the operation mode is changed

in sequence: (I FEEL...) (AUTO) (COOL) (DRY) (HEAT)

I FEEL

HEAT AUTO

DRY COOL

MODE

FAN

VANE

STOP

START

HR.

Details of display on the indoor unit

The operation indicator at the right side of the indoor unit indicates the operation state.

Operation Indicator

Lighted

Not lighted

 

ECONO COOL

MIN

Description of “AUTO RESTART FUNCTION”

These units are equipped with an auto restart function. When the main power is turned on, the air conditioner will start operation automatically in the same mode as the one set with the remote controller before the shutoff of the main power.

If the unit was set to off with the remote controller before the shutoff of the main power, it will remain stopped even after the main power is turned on.

If the unit was in the emergency operation before the shutoff of the main power, it will start operation, when main power comes on, in the same mode as the one set with the remote controller before the emergency operation.

If the unit is operated in “I FEEL...” or “AUTO” mode before power failure, the operation mode (COOL, DRY or HEAT) is not stored in the memory. When the main power is turned on, the unit decides the operation mode by the initial room temperature at restart and starts operation again.

Operation indicator lamp

Indication

Operation state

Difference between target

temperature and room temperature

 

 

 

 

 

 

This shows that the air conditioner is operating to reach the

 

 

target temperature. Please wait until the target temperature

About 2°C or more

 

is obtained.

 

 

 

 

 

This shows that the room temperature is approaching the

About 2°C or less

 

target temperature.

 

 

 

 

 

6

Image 6
Contents English Deutsch Français Nederlands Español Italiano Português Dansk Svenska Türkçe РусскийContents Safety PrecautionsName of Each Part For installationIndoor unit When installed on the floor Outdoor unitRemote controller Auto restart function Indoor unitAuto restart function is Remote controller How to set the batteries and the current timePreparation Before Operation Description of I FEEL... mode FEEL... Auto OperationWhen the set temperature is to be changed To select the COOL, DRY or Heat modeTo select the Auto mode Description of Auto ChangeoverFor the ceiling suspended unit AIR Flow Velocity and Direction AdjustmentFor the floor standing unit To change the horizontal direction of the AIR FlowTimer Operation ON/OFF Timer MaintenanceEcono Cool Operation Install the air filter Cleaning the air filter about once every 2 weeksCleaning the deodorizing filter about once every 2 weeks Remove the air filterWhen YOU Think That Trouble has Occurred VN79A517H01

MCFZ-A12WV specifications

The Mitsubishi Electronics MCFZ-A12WV is an advanced compact air conditioning unit designed to provide efficient and reliable climate control for both residential and commercial applications. With its innovative technology and user-friendly features, the MCFZ-A12WV stands out as a top choice for those seeking comfort and energy efficiency.

One of the most notable features of the MCFZ-A12WV is its high energy efficiency rating. This unit utilizes advanced inverter technology, which allows it to adjust the compressor speed according to the cooling demand. This not only ensures optimal temperature control but also significantly reduces energy consumption compared to traditional fixed-speed models. As a result, users can enjoy a comfortable indoor environment while keeping their energy bills in check.

The MCFZ-A12WV is equipped with a powerful cooling capacity of 3.5 kW, making it suitable for medium-sized spaces. It is also designed to deliver rapid cooling performance, allowing users to achieve their desired temperature in a short amount of time. The whisper-quiet operation of this unit ensures that it functions unobtrusively, creating a peaceful atmosphere within the home or office.

User convenience is a key aspect of the MCFZ-A12WV’s design. The unit comes with an intuitive remote control that allows users to easily adjust settings such as temperature, fan speed, and operating mode from a distance. Additionally, the programmable timer function enables users to set specific operating times, ensuring the air conditioning unit runs only when needed.

Mitsubishi Electronics has also prioritized air quality in the MCFZ-A12WV, incorporating a multi-stage filtration system that effectively removes dust, allergens, and other airborne pollutants. This feature contributes to a healthier indoor environment, making it ideal for households with allergies or respiratory concerns.

The MCFZ-A12WV is designed with durability and long-term performance in mind. It features a robust construction that can withstand various environmental conditions, while its eco-friendly refrigerant minimizes the unit's environmental impact.

In conclusion, the Mitsubishi Electronics MCFZ-A12WV combines state-of-the-art technology with energy efficiency, user-friendliness, and a focus on air quality. Whether for home or office use, it provides a reliable solution for effective climate control, ensuring comfort and well-being all year round.