1-4. INSTALLATION DIAGRAM
ACCESSORIES
Check the following parts before installation. <Indoor unit>
(1) | Installation plate | 1 |
|
|
|
| Attachment screws for the installa- |
|
(2) | tion plate | 7 |
| 4 × 25 mm |
|
|
|
|
(3) | Remote controller holder | 1 |
|
|
|
| Screws for the remote controller |
|
(4) | holder | 2 |
| 3.5 × 16 mm (Black) |
|
|
|
|
(5) | Battery (AAA) for (6) | 2 |
|
|
|
(6) | Wireless remote controller | 1 |
|
|
|
(7) | Felt tape | 2 |
(For left or | ||
|
|
|
(8) | $LUFOHDQLQJ¿OWHU | 2 |
|
|
|
(9) | Charge nut | 1 |
|
|
|
(10) | 1 | |
|
|
|
|
| |
(A) Indoor/outdoor unit connecting wire * | 1 | |
|
|
|
(B) | Extension pipe | 1 |
(70 | more/ | mm) | and | piping | spacer) |
in. | (130 | for | |||
13/16 | or | in. | more | back | (using |
2 | mm) | 1/8 | |||
- |
| 5 |
| left | |
|
|
|
|
| |
|
| - | or |
|
|
|
|
|
|
|
Use the wall hole sleeve
(C) to prevent indoor/out- door connecting wire (A) from contacting metal parts in the wall and to protect the wiring from rodents.
4- |
|
| |
11/16 | in. | ||
(120 |
| ||
mm) | |||
or | |||
more |
8- |
|
|
11/16 | in. | |
(220 |
| |
or | mm) | |
more |
| Wall hole cover (D) |
Indoor unit | Seal the wall hole |
| gap with putty (H). |
Wall hole | Attach the pipe to |
sleeve (C) | |
| wall with pipe at- |
| tachment strap (E). |
Cut off the
extra length.
Pipe attach- ment strap
(E)
Attachment screw (F)
After the leak test, apply insulating mate- rial tightly so that there is no gap.
Space for indoor unit working
Please leave the space as shown in the picture for maintenance usage.
4 in. (100 mm) or more
| ormm)more | |
| Installation |
|
Indoor unit | plate |
|
|
| Space |
(C) | Wall hole sleeve | 1 |
(D) | Wall hole cover | 1 |
|
|
|
(E) | Pipe attachment strap | 2 to 5 |
|
|
|
(F) | Screw for (E) 4 × 20 mm | 2 to 5 |
|
|
|
(G) | Piping tape | 1 |
|
|
|
(H) | Putty | 1 |
|
|
|
| Drain hose |
|
(I) | (or soft PVC hose, 19/32 in. [15 | 1 |
mm] inner diameter or hard PVC | ||
| pipe VP16) |
|
|
|
|
(J) | Refrigerant oil | 1 |
|
|
|
(K) | Power supply cord * | 1 |
Note: | mm) |
Do not | 5/16in.(7 moreor |
obstruct | |
the air | |
outlet. |
|
20 in. (500 mm) or more
When the piping is to be attached to a wall comprised of tin plate or metal netting, use chemically treated wooden piece 25/32 in. (20 mm) or thicker between the wall and the piping, or wrap insulation vinyl tape 7 to 8 turns around the piping.
To use existing piping, perform COOL operation for 30 minutes and pump down before removing the old air conditioner.
5HPDNHÀDUHDFFRUGLQJWRWKHGLPHQVLRQ for new refrigerant.
Outdoor unit installation
|
| Unit: inch | |
|
|
| |
|
* Note:
Place indoor/outdoor unit connecting wire (A) and power supply cord (K) at least 3 ft. (1 m) away from the TV antenna wire.
| 4 |
(100 in. | |
or | mm) |
| more |
in. 20 mm) (500more or
| . |
in | |
4 | mm) |
| |
(100more | |
or |
|
| 14 | in. | |
(350 |
| ||
or |
| mm) | |
| more |
Air inlet |
|
Air outlet |
|
Unit: mm
840
100500
Air inlet
392 | 330 | 360 |
| Air outlet |
|
| 40 |
Units should be installed by licensed contractor according to local code requirements.