Mitsubishi Electronics MSY-D30/36NA Installation Diagram, Accessories, FIELD-SUPPLIED Parts

Page 3

1-4. INSTALLATION DIAGRAM

ACCESSORIES

Check the following parts before installation. <Indoor unit>

(1)

Installation plate

1

 

 

 

 

Attachment screws for the installa-

 

(2)

tion plate

7

 

4 × 25 mm

 

 

 

 

(3)

Remote controller holder

1

 

 

 

 

Screws for the remote controller

 

(4)

holder

2

 

3.5 × 16 mm (Black)

 

 

 

 

(5)

Battery (AAA) for (6)

2

 

 

 

(6)

Wireless remote controller

1

 

 

 

(7)

Felt tape

2

(For left or left-rear piping)

 

 

 

(8)

$LUFOHDQLQJ¿OWHU

2

 

 

 

(9)

Charge nut

1

 

 

 

(10)

L-joint

1

 

 

 

FIELD-SUPPLIED PARTS

 

(A) Indoor/outdoor unit connecting wire *

1

 

 

 

(B)

Extension pipe

1

(70

more/

mm)

and

piping

spacer)

in.

(130

for

13/16

or

in.

more

back

(using

2

mm)

1/8

-

 

5

 

left

 

 

 

 

 

 

 

-

or

 

 

 

 

 

 

 

Use the wall hole sleeve

(C) to prevent indoor/out- door connecting wire (A) from contacting metal parts in the wall and to protect the wiring from rodents.

4-

 

 

11/16

in.

(120

 

mm)

or

more

8-

 

 

11/16

in.

(220

 

or

mm)

more

 

Wall hole cover (D)

Indoor unit

Seal the wall hole

 

gap with putty (H).

Wall hole

Attach the pipe to

sleeve (C)

 

wall with pipe at-

 

tachment strap (E).

Cut off the

extra length.

Pipe attach- ment strap

(E)

Attachment screw (F)

After the leak test, apply insulating mate- rial tightly so that there is no gap.

Space for indoor unit working

Please leave the space as shown in the picture for maintenance usage.

4 in. (100 mm) or more

 

27/32-9in. (250

ormm)more

 

Installation

 

Indoor unit

plate

 

 

 

Space

(C)

Wall hole sleeve

1

(D)

Wall hole cover

1

 

 

 

(E)

Pipe attachment strap

2 to 5

 

 

 

(F)

Screw for (E) 4 × 20 mm

2 to 5

 

 

 

(G)

Piping tape

1

 

 

 

(H)

Putty

1

 

 

 

 

Drain hose

 

(I)

(or soft PVC hose, 19/32 in. [15

1

mm] inner diameter or hard PVC

 

pipe VP16)

 

 

 

 

(J)

Refrigerant oil

1

 

 

 

(K)

Power supply cord *

1

Note:

mm)

Do not

5/16in.(7 moreor

obstruct

the air

outlet.

 

20 in. (500 mm) or more

When the piping is to be attached to a wall comprised of tin plate or metal netting, use chemically treated wooden piece 25/32 in. (20 mm) or thicker between the wall and the piping, or wrap insulation vinyl tape 7 to 8 turns around the piping.

To use existing piping, perform COOL operation for 30 minutes and pump down before removing the old air conditioner.

5HPDNHÀDUHDFFRUGLQJWRWKHGLPHQVLRQ for new refrigerant.

Outdoor unit installation

 

 

Unit: inch

 

 

33-1/16

 

3-15/16

19-11/16

 

* Note:

Place indoor/outdoor unit connecting wire (A) and power supply cord (K) at least 3 ft. (1 m) away from the TV antenna wire.

 

4

(100 in.

or

mm)

 

more

in. 20 mm) (500more or

 

.

in

4

mm)

 

(100more

or

 

 

14

in.

(350

 

or

 

mm)

 

more

Air inlet

 

15-14/32 13

14-3/16

Air outlet

 

4-3/8 x 13/16 slot

1-18/32

Unit: mm

840

100500

Air inlet

392

330

360

 

Air outlet

 

 

4-10 x 21 slot

40

Units should be installed by licensed contractor according to local code requirements.

Image 3
Contents SPLIT-TYPE AIR Conditioners Before InstallationInstallation Manual Following should Always be Observed for SafetyRefrigerant Pipes Selecting the Installation LocationSpecifications Power Supply and INDOOR/OUTDOOR Wire ConnectionFIELD-SUPPLIED Parts Installation DiagramAccessories Outdoor unit installationDrilling Indoor Unit InstallationAttaching the Installation Plate Connecting Wires for Indoor UnitLeft or left-rear piping Installing the L-JOINTPipe Forming and Drain Piping Pipe FormingRight piping Outdoor Unit InstallationConnecting Wires for Outdoor Unit Drain PipingPipe Connection Purging PROCEDURES, Leak TEST, and Test RUNPurging Procedures and Leak Test Flare ConnectionRelocating the Unit / Maintenance