Mitsubishi Electronics GB-24A operation manual Performing Operations

Page 7

3 Performing Operations

Text below explains how to connect to the GB-24A and how to perform various settings.

Note: If the GB-24A is restarted due to a power interruption etc., wait until the screen on the GB-24A main unit displays the normal operation screen (it takes several minutes before the normal operation screen is displayed) before using a web browser to access the GB-24A. If access is attempted while the GB-24A is still starting up, the most recent data might not be displayed or communication errors could occur.

Note: Default IP address of GB-24A is "192.168.1.1". (Factory setting)

3-1 Entering the User Name and the Password, and Connecting to the GB-24A

(1)Enter the web page address in the address field of the web browser as follows:

http:// [IP address of the GB-24A]/g-50/ administrator.html

Press the [Enter] key on the keyboard. A screen appears for login.

Note: For example, type “http://192.168.1.1/g-50/administrator.html” if the

GB-24A IP address is [192.168.1.1].

(2)To make connection easier for the next time, click the web browser menu item [Favorites], click [Add to Favorites], then add the address to the Favorites folder. Once this address is added to the Favorites folder, it is not necessary to input the address of (1). Simply select it from the Favorites folder and the GB-24A page will appear.

(3)Enter the user name and the password in the login screen, and click the [Login] button. A screen will appear in which various setting are made. Procedures for making proper settings on each screen will be explained in the following pages.

The table below shows the default user names and passwords for maintenance users and managers, as well as available functions.

User

Default

Default

 

Available functions

user name

password

 

 

 

 

 

 

 

Initial settings

Date and Time, Basic System, Groups, Interlocked

 

 

 

LOSSNAY, Blocks

Maintenance

initial

init

 

 

Functions 1

E-Mail, Measurement

user

 

 

 

Set Temperature Range Limit, Night Mode

 

 

 

Functions 2

 

 

 

Schedule

 

 

 

 

 

 

 

 

 

 

 

 

Out of the functions listed above, the items to which access rights have been

manager

administrator

admin

given on the user settings screen are available. (Refer to Chapter 7 "User

 

 

 

Setting.")

 

Note: The user name and the manager’s password are the same as those of the manager of the Web for monitoring/operation.

Note: Maintenance users can make available to the administrator only the information necessary for normal operation (group name setting etc.)

Note: It is recommended to change the user name and password, so users other than the manager are not permitted to change the settings.

6

Image 7
Contents Centralized Controller Terms Used in This Manual IntroductionComputer Requirements Setting the PC IP Address Setting the Operating EnvironmentPage Internet connection using a dial-up Setting the Web BrowserNo Internet Connection Specify Performing Operations Http// IP address of the GB-24A/g-50/ administrator.htmlSetting the Current Date and Time Initial SettingsRefresh 1 GB-24A Unit Setting Setting Basic Information and External Input FunctionsNetwork Setting NET SettingPage Settings for when the GB-24A is connected to a dedicated LAN External Input Setting Settings for when the GB-24A is connected to an existing LAN1.0 Seconds Setting the Display Format Setting the Group Name Group SettingRegistering air conditioner units in the group Registering general equipment in the group Interlocked Lossnay Registration Interlocked SettingInterlocked Indoor Units Registration Registering a group in a block Block SettingRefresh Save Settings Registering a block nameFunctions Error mail reports/E-mail communicationMail settings of GB-24A Error Mail SettingsSetting the Error Mail Destinations Setting the Mail Server InformationMail format Setting the Addresses of the RecipientRegistering AI controllers for temperature/humidity sensors Settings for measurementValue per pulse Measurement unit Setting details of sensor Adjusting the measured temperature/humidity valuesSetting the trend data format Measured Address Setting details of sensor Scroll barSetting the destination to which an error mail is sent Be applied Limiting the Set Temperature Operating Range Night mode start time Night mode end time Night Mode Silent Mode ScheduleTarget outdoor units Available functions User SettingMaintenance user name, password User name and password for building managerAvailable Function List License number entry field Registering a License for Optional FunctionsWT05504X02 Recycled Paper

GB-24A specifications

The Mitsubishi Electronics GB-24A is a highly regarded air conditioning unit that exemplifies modern technology and efficiency. Designed for both residential and commercial applications, it offers a myriad of features that cater to the diverse needs of users while maintaining a significant focus on energy conservation and environmental sustainability.

One of the standout features of the GB-24A is its remarkable efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) rating that meets and often surpasses many industry standards, this model ensures that users experience optimal cooling without incurring exorbitant energy costs. The advanced inverter technology further enhances energy savings by adjusting the compressor speed in real-time to match the desired set temperature, reducing energy consumption significantly compared to non-inverter models.

The unit is equipped with a powerful yet quiet operation mode, making it ideal for use in bedrooms or office spaces where noise levels need to be kept to a minimum. This is achieved through precision engineering and thoughtful design that minimizes vibration and operational noise.

Additionally, the GB-24A features advanced filtration systems that help to improve indoor air quality. The built-in air purifying filter removes dust, allergens, and other airborne pollutants, making it particularly beneficial for allergy sufferers and those with respiratory issues. The self-cleaning capability also aids in maintaining hygiene, as it prevents mold and bacteria build-up.

Another noteworthy characteristic is the intelligent control options provided with the GB-24A. Users can conveniently manage the climate from anywhere using a smartphone app, allowing for remote operation and programming. This feature is complemented by programmable timers and multiple operation modes, including cooling, heating, and dehumidification, making it a versatile unit for year-round use.

In terms of installation, the GB-24A is designed for flexibility. It can be mounted in various configurations, making it suitable for a range of indoor environments. This versatility, combined with its compact design, enables it to fit seamlessly into any space.

In conclusion, the Mitsubishi Electronics GB-24A stands out for its energy-efficient operation, advanced air purification technology, and smart control features. Whether for residential or commercial use, this air conditioning unit provides users with reliable performance, comfort, and peace of mind, making it a top choice in its category.