Mitsubishi Electronics PMFY-P08NBMU-E Auto Operation Automatic COOL/HEAT Change Over Operation

Page 19

8-5. AUTO OPERATION [AUTOMATIC COOL/HEAT CHANGE OVER OPERATION]

 

 

TIME SUN MON TUE WED THU FRI SAT

 

 

 

TIMER

Hr ON

 

 

 

AFTER

AFTER OFF

 

 

 

ERROR CODE

FUNCTION

 

˚F˚C

 

˚F˚C

FILTER

 

 

 

 

 

 

WEEKLY

 

 

ONLY1Hr.

 

SIMPLE

 

 

 

AUTO OFF

 

TEMP.

 

ON/OFF

 

MENU

ON/OFF

 

FILTER

BACK

MONITOR/SET

DAY

 

CHECK TEST

PAR-21MAA

CLOCK

OPERATION

CLEAR

<How to operate>

1Press POWER ON/OFF button.

2Press the operation MODE button to display AUTO.

3 Press the TEMP. button to set the desired temperature.

NOTE: The set temperature changes 2°F when the or button is pressed once. Automatic 67 to 83°F.

When in AUTO mode, the unit will switch from either heat or cool automatically to maintain the set temperature.

Control modes

Control details

Remarks

 

 

 

1. Initial value of

HEAT mode for room temperature < Desired temperature

 

operation mode

COOL mode for room temperature ] Desired temperature

 

 

 

 

2. Mode change

(1) HEAT mode COOL mode

 

 

Room temperature ] Desired temperature + 3°F or 3 minutes has passed

 

 

(2) COOL mode HEAT mode

 

 

Room temperature [ Desired temperature - 3°F or 3 minutes has passed

 

 

 

 

3. COOL mode

Same control as cool operation

 

 

 

 

4. HEAT mode

Same control as heat operation

 

 

 

 

8-6. WHEN UNIT IS STOPPED

Control modes

Control details

Remarks

 

 

 

1. Drain pump

1-1. Drain pump control

 

 

The drain pump turns ON for the specified amount of time when any of the

 

 

following conditions is satisfied.

 

 

(regardless of whether the compressor is ON or OFF)

 

 

1 ON for 3 minutes after the operation mode is switched from COOL or DRY to

 

 

another operation mode (HEAT mode).

 

 

2 ON for 6 minutes after the drain sensor is determined to be submerged using the

 

 

liquid level detection method given below.

 

 

3 ON for 6 minutes after indoor piping (liquid piping) temperature – indoor room

 

 

temperature [ 14°F, and the drain sensor input is at the short or open level.

 

 

(If condition 2 or 3 is still being met after the drain pump has been turned ON for 6

 

 

minutes, the drain pump is kept ON for a further 6 minutes.)

 

1-2. Liquid level detection method

The liquid level is detected by determining whether or not the drain sensor is submerged, based on the amount the temperature rises after self-heating the sensor.

This process is performed if any of the following conditions is satisfied:

1Drain pump is ON.

2Indoor piping (liquid piping) temperature – indoor room temperature [ 14°F (except during defrosting)

3Indoor piping (liquid piping) temperature or indoor room temperature is at the

short or open level temperature.

4Every 1 hour after the drain pump has been switched from ON to OFF.

19

Image 19
Contents Revised EDITION-B ContentsTechnical Changes FeaturesRemove dust and pollutants from return air Part Names and FunctionsReturns air from room ˚F˚C Display SectionSpecifications SpecificationWNote Refer to Wiring Diagram for the supplied voltage Electrical Parts SpecificationsAIR Capacity Taken from Outside How to read curvesOperation in conjunction with duct fan Booster fan PMFY-P12NBMU-E Noise Criterion Curves PMFY-P06NBMU-EPMFY-P15NBMU-E PMFY-P08NBMU-ETop Installation space required aroundRight side IndoorPMFY-P06NBMU-E PMFY-P08NBMU-E Wiring DiagramPmfy PMFY-P06NBMU-E1PMFY-P08NBMU-E1E1PMFY-P15NBMU-E1 Unitin.mm Refrigerant System DiagramPressed once. Cooling 67 to 87F How to operateMicroprocessor Control Indoor Unit Control 8-1. Cool OperationDrain sensor function Control modes Drain pump VaneBasic control system Drain pump Same control as Cool operation Vane Desired temperatureDRY Operation Pressed once. Dry 67 to 87FFAN Operation On the vanes downward blow settingPressed once. Heating 63 to 83F Heat OperationDisplay in Heat operation Defrost From the preceding Auto Operation Automatic COOL/HEAT Change Over Operation When Unit is StoppedTrouble Shooting Operation summary of the linear expansion valve Linear expansion valveTrouble shooting Output PhaseLinear expansion valve operation Indoor controller board fuse check Yes TroubleshootingAny broken wire by using a tester Replace the fuse Replace the fan motorFunction of DIP Switch SW12 Switch Pole SW11SW14 Switch Operation by switch EffectiveSW4 Operating Procedure PHOTOS&ILLUSTRATIONS Disassembly ProcedureRemoving the nozzle Removing the electrical parts boxRemoving the vane motor Removing the drain pump Removing the thermistorRoom temperature detectionRemoving the fan motor and line flow fan E11 003 Part Name SpecificationQty/set Remarks Drawing NoPart number that is circled is not shown in the figure Electrical Parts PMFY-P06NBMU-E PMFY-P08NBMU-E E04 RoHSE16 R01 E01 E07 E14 E15R01 E01 079 R01 23A 102R01 E04 103 R01 E32 114R01 E21 246 Qty/setE41 716 R01 E27 246Made in Japan

PMFY-P08NBMU-E, PMFY-P12NBMU-E1, PMFY-P08NBMU-E1, PMFY-P06NBMU-E, PMFY-P12NBMU-E specifications

Mitsubishi Electronics has long been a pioneer in the field of air conditioning and climate control technologies. Among their impressive lineup of products is the PMFY series, which includes models such as the PMFY-P06NBMU-E1, PMFY-P12NBMU-E, PMFY-P06NBMU-E, PMFY-P08NBMU-E1, and PMFY-P12NBMU-E1. These advanced air conditioning systems are engineered to offer optimal comfort, energy efficiency, and innovative features for both residential and commercial applications.

One of the standout features of the PMFY series is its exceptional energy efficiency. Many models are equipped with advanced inverter technology, which allows for precise temperature control while significantly reducing energy consumption. This results in lower electricity bills and a reduced carbon footprint, making them an environmentally friendly choice for conscientious consumers.

Another key characteristic of the PMFY series is its advanced filtration system. These units are designed to improve indoor air quality by incorporating high-performance filters that effectively remove dust, allergens, and other pollutants. This is especially beneficial for individuals with respiratory conditions, contributing to a healthier indoor environment.

The PMFY models also boast a sleek and modern design, ensuring they blend seamlessly with any interior décor. Compact and lightweight, they can be installed in various settings, maximizing available space without compromising on performance.

Mitsubishi’s proprietary technology features an intelligent control system that allows users to manage their air conditioning units remotely. With options for Wi-Fi connectivity and compatibility with smart home systems, users can easily set schedules, adjust temperatures, and monitor energy usage from their smartphones or tablets.

Noise reduction is another important aspect of the PMFY series. These units operate at whisper-quiet levels, ensuring a peaceful atmosphere in homes and workplaces. This noise control technology is particularly advantageous for bedrooms, offices, and other quiet environments.

Lastly, the PMFY series is designed to be robust and reliable, with components that are engineered for durability and long life. Mitsubishi Electronics stands behind their products with comprehensive warranties, providing peace of mind and exceptional customer service.

In summary, the Mitsubishi Electronics PMFY-P06NBMU-E1, PMFY-P12NBMU-E, PMFY-P06NBMU-E, PMFY-P08NBMU-E1, and PMFY-P12NBMU-E1 are exemplary models that embody the essence of innovation, efficiency, and reliability. They represent the ideal choice for those seeking advanced climate control solutions suitable for a variety of spaces.