Mitsubishi Electronics PCFY-P24NKMU-E, PCFY-P15NKMU-E Gas pipe side/flared connection

Page 10

 

 

[FRONT VIEW]

 

 

 

 

5

1

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10-1/4(260)

 

 

1/2(190)-7

 

3(76)

 

 

 

 

 

3-3/8(85)

1/16(1)

15/16(126)-4

3

 

 

 

 

 

3-3/8(86)

 

Electrical box

 

 

 

 

 

 

 

 

 

 

2

0

°

 

1/16(2)

 

 

 

 

Ceiling

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-13/16(46)

2-15/16(75)

2When electrical box is pulled down

4-7/8(124)

 

)

 

5

3/4(121)-4

2

-

 

1

 

 

6

 

/1

 

5

 

1

 

4

 

Φ

18-1/8(461)

11/16(18)

1-1/2(38)

15-1/4(387)

8 7

5-7/16(138)

1-7/16(37)

7-1/2(190)

In case of the rear pipe arrangement, make sure to remove the shaded portions from the independent piece. Then put the independent piece back in initial

position.(The heat exchanger might be clogged because of dust)

5/16(8)

1-7/8(48)

1/16(2)

Electrical box

10

2

 

When drain socket

9-3/16(233) is installed

9-11/16(246) Drainage

1Drainage pipe connection(1(26mm)I.D.)

NOTES.

1.Use M10 or W3/8 screw for anchor bolt. 2.Please be sure when installing the drain lift up mechanism (option parts),refrigerant pipe will be only upward.

61-5/16(1557) (Suspension bolt pitch)

7/8(150)-5

11/16(18)

5-1/2

140

 

 

63(1600)

58-3/4(1493)

Air outlet

7-3/16

182

6

62

2-7/16

1/8

80

3-

 

12-5/8(320)

26-3/4(680)

 

2(51)

1/16(2)

3/8(10)

 

3/16(5)

 

 

 

9-1/16(230)

 

5/16(84)-3

7/16(88)-3

11/16(195)-

9/16

14

remote controller

 

 

 

 

In case of wireless

 

 

7

and i-see sensor

 

 

 

 

 

3-3/8

 

(Optional Parts)

 

85

 

 

 

 

PCFY-P30, 36NKMU-E

9-5/16(236)

 

7-1/16(180)

liquid Φ3/8(Φ9.52)

7-7/8(200)gas Φ5/8(Φ15.88)

9-3/16(233) When drain socket is installed

9-11/16(246) Drainage

2Drainage pipe connection(for the left arrangement)

3 Knock out hole for left drain-piping arrangement 4 Refrigerant-pipe connection

(gas pipe side/flared connection)

5 Refrigerant-pipe connection (liquid pipe side/flared connection)

6 Knock out hole for upper drain pipe arrangement

7 Knock out hole for fresh air intake Φ3-15/16(Φ100) 8 Knock out hole for wiring arrangement Φ7/8(Φ22)

Accessory...Drain socket (1(26mm)I.D.)

59-3/4(1518)

 

2-1/4

57

In case of wireless remote controller

 

 

 

10(254)

3/4(476)-18

3/4(680)-26

and i-see sensor(Optional Parts)

Emergency operation

Emergency operation

 

 

 

switch <Cooling>

switch <Heating>

Receiver

DEFROST/STAND BY lamp

 

Operation lamp

Air intake

 

Unit : inch(mm)

Image 10
Contents Contents Parts Catalog OCB450Part Names and Functions Wired remote controller Specification SpecificationsElectrical Parts Specifications Sound LevelNC Curves PCFY-P15NKMU-E PCFY-P24NKMU-EHow to read curves CmmcfmFront View Pcfy Gas pipe side/flared connection Wiring Diagram PCFY-P15, 24, 30, 36NKMU-EPCFY-P15NKMU-E PCFY-P24NKMU-E PCFY-P30NKMU-E PCFY-P36NKMU-E Refrigerant System DiagramUnit mm inch Service Ref Ø12.7 1/2 Ø15.88 5/8Microprocessor Control How to operateRoom temperature Desired temperature Indoor Unit Control 6-1. Cool OperationFloat switch control Control modes Control details Remarks Thermo regulating DRY OperationPressed one time. Dry 67 to 87F Drain pump Same control as Cool operation VaneFAN Operation Display in Heat operation Defrost Heat OperationPressed one time. Heating 63 to 83F Fan Control detailsControl modes Control details Remarks Fan Thermo OFF mode From the precedingWhen Unit is Stopped Auto Operation Automatic COOL/HEAT Change Over OperationTroubleshooting DownLinear expansion valve Become OFF Trouble shootingClosing a valve 1 → 2 → 3 → 4 → ValveSensor signal check Function of DIP Switch Switch Match the indoor unit’s refrigerant pipe with the BC High ceiling On SWA settingHow to set address How to set branch number SW14 Series R2 onlyJumper Switch PoleOperation by switch Effective Pattern aTest Point Diagram PCFY-P15NKMU-E PCFY-P24NKMU-E PCFY-P30NKMU-E PCFY-P36NKMU-ESW1 PCFY-P15NKMU-E PCFY-P24NKUM-E Disassembly ProcedureOperating Procedure Photos & Illustrations PCFY-P30NKMU-E PCFY-P36NKMU-ERemoving the room temperature thermistor TH21 Removing the fan motor and right side fanRemove the screw from the side panel, and remove Removing the fan 3 connectionRemoving the side panel Side panel by sliding the panel to the frontRemoving the under panel Removing the vane motorRemoving the drain pan Removing the guide vane Removing the pipe thermistors/Liquid TH22 and GasTH23 Removing the Auto vaneRemove 2 screws from the heat exchanger Removing the heat exchanger and LEVRemove the heat exchanger with LEV Page New publication, effective Feb

PCFY-P30NKMU-E, PCFY-P36NKMU-E, PCFY-P24NKMU-E, PCFY-P15NKMU-E specifications

Mitsubishi Electronics is renowned for its innovative solutions in the field of heating, ventilation, and air conditioning (HVAC) systems. Among its impressive lineup, the PCFY-P series of ceiling-mounted air conditioning units stands out for its advanced features, technologies, and efficient performance. The models PCFY-P15NKMU-E, PCFY-P24NKMU-E, PCFY-P36NKMU-E, and PCFY-P30NKMU-E cater to various cooling and heating needs, making them suitable for both residential and commercial applications.

One of the main features of the PCFY-P series is its superior efficiency rating. With advanced inverter technology, these units provide precise temperature control by adjusting the compressor speed to match the cooling or heating demand. This not only leads to significant energy savings but also ensures a comfortable environment at all times.

Another notable characteristic of the PCFY-P series is its whisper-quiet operation. Designed with noise-reduction technologies, these models operate at sound levels as low as 19 dB, making them ideal for environments requiring minimal disturbance, such as offices, libraries, or bedrooms.

The multi-zone capability of the PCFY-P series enhances its versatility. Each model can connect to multiple indoor units, allowing users to customize their climate control across different zones in a building. This adaptability facilitates tailored cooling or heating solutions, optimizing comfort and energy use.

Mitsubishi's advanced filtration systems improve indoor air quality by removing dust, allergens, and microorganisms. The PCFY-P series is equipped with highly efficient filters, ensuring that the air circulated is clean and healthy.

Smart technology integration is another hallmark of these models. With built-in Wi-Fi capability, they can be remotely controlled through a smartphone app or accessed via various smart home systems. This feature allows users to adjust settings, monitor energy consumption, and schedule operation times conveniently.

Sustainability is a key focus in Mitsubishi's design philosophy. The PCFY-P series utilizes environmentally friendly refrigerants that have a low global warming potential, aligning with modern environmental regulations and initiatives.

In summary, the Mitsubishi Electronics PCFY-P15NKMU-E, PCFY-P24NKMU-E, PCFY-P36NKMU-E, and PCFY-P30NKMU-E offer exceptional efficiency, quiet operation, air quality improvement, smart technology integration, and sustainable design. These characteristics position the PCFY-P series as a leading choice in the HVAC market, providing reliable comfort solutions for a variety of settings. Each model exemplifies Mitsubishi's commitment to innovation and performance, making them a valuable asset for climate control needs.