Installation
Mounting the hood body
63mm
|
| 170mm | ceiling |
|
|
| |
|
|
| top flue fixing holes |
|
|
| for recirculating mode |
|
|
| bottom fixing holes for |
|
|
| |
|
|
| 190mm |
|
|
| top edge of |
|
|
| motor housing |
|
| 120mm | key hole fixings |
|
| for wall mounting | |
428mm | 363mm |
| |
243mm |
| ||
|
|
| hood |
|
|
| base |
top
of hob
1.Using a spirit level mark a vertical centre line on the wall where the hood is to be positioned, and a horizontal line at the hood base position (refer Mounting the hood body).
NOTE: The height of the underside of the hood body must be a minimum of 600mm above an electric cooktop & 650mm above a gas cook top and a maximum height of 800mm (refer to table below).
Distance from hood base to top of hob
hob type | minimum* | maximum |
gas | 650mm | 800mm |
electric | 600mm | 800mm |
*If the instructions of the hob specify a greater distance than the minimum above, this shall be the minimum height for installation
2.Mark the location for the four (4)
3.Fix four (4) suitable screws (to support a total weight of 40kg) into the wall at the positions marked in step 2 to allow the body of the hood to be hung on the wall. Leave a
NOTE: Screw head must be between 7mm and 11mm diameter, with screw thread diameter to be less than 5.5mm to suit
4.Hang the body of the hood on the wall using the screws attached in step 3. To secure the hood body, use two
(2) suitable screws and fix the
housing to the wall.
electrolux e:line rangehood installation 3
Depending on the preferred installation/ducting mode, follow step 5a or 5b below:
5.a) Recirculating Mode: Using the centre line, secure the flue fixing bracket to the wall with suitable screws, so that the location of the fixing holes are 63mm from the ceiling. Attach the recirculating
OR
5.b) Ducted Mode: Continue the centre line to the ceiling. Mark a line on the ceiling 14mm away from the wall. Locate the back edge of the flue cover mounting bracket on this line and centre. Screw the bracket to the ceiling using suitable screws.
ø150mm | ø150mm |
NOTE: Flue pipe shown is not included - must be purchased separately.
important
In recirculating mode, you must use carbon filters to eliminate cooking smells (Carbon filter model no. EFF72).
NOTE: To ensure best performance of the rangehood use of straight ducting is recommended. The use of bends should be avoided. Rigid flexible ducting is suitable, although loose flexible ducting is unacceptable.
All ducting must be fire retardant.
6.Connect an internal flue pipe (not included) between the fan outlet to the inlet of the
NOTE: Before installing outer flue cover, ensure the power cord is connected to a suitable powerpoint.