Warewashing 66″ Single Tank Conveyor Dishwasher without Built In Hot Water Booster WT66
Electric
Supply voltage: | 534094 (WT66CL208) | 208 V/3p/60Hz |
| 534095 (WT66CR208) | 208 V/3p/60Hz |
| 534096 (WT66CL240) | 240 V/3p/60Hz |
| 534097 (WT66CR240) | 240 V/3p/60Hz |
Machine requires one electrical connection. |
| |
Max. Current absorbed: | 208 V/3p/60Hz | 64A (21 kW) |
| 240 V/3p/60Hz | 57.5A (21 kW) |
Water
Inlet Water supply pressure: | 22 – 102 psi (150 – 700 kPa) |
Inlet Cold Water Supply Temperature |
|
for Pre Wash Tank: | |
Inlet Water Supply Temperature |
|
Rinse circuit: | 194 °F (90 °C) |
Wash tank: | 80 – 140 °F (27 – 60 °C) |
Inlet Water supply hardness: | 4 – 8 gpg |
Incoming Cold Water line size | G 3/4″ |
Pre wash: | |
Incoming Hot Water line size | G 3/4″ |
Wash tank: | |
Rinse circuit: | G 3/4″ |
Drain line size | G |
Pre wash section: | |
Wash/rinse section: | G |
Water consumption: Gallons/hr: | 83.2 gal/hr (315 liters) |
Water consumption/rack: | 0.4 gal/rack (1.5 l/rack) |
Pre wash temperature: | < 105 °F (<40 °C) |
Pre wash tank size: | 11.8 gal (45 liters) |
Pre wash pump power: | 0.5 hp (0,37 kW) |
Pre wash pump water flow: | 39 gal/min (150 l/min) |
Wash temperature: | 160 – 172 °F |
Wash tank size: | 26 gal (100 liters) |
Wash pump power: | 2 hp (1.5kW) |
Wash pump flow rate: | 118.9 gal/min (450 l/min) |
Rinse temperature: | 180 – 194 °F |
Rinse pump power: | 0.4 hp (0.32 kW) |
Rinse pump water flow: | 1.32 gal/min (5 l/min) |
Initial fill Hot Water requirements: | 26 gal (100 liters) |
Initial fill Cold Water requirements: | 11.8 gal (45 liters) |
Key Information
Productivity racks per hour | 200 racks / 3600 dishes |
(max speed): | (average 18 dishes per rack) |
Productivity racks per hour | 130 racks / 2340 dishes |
(min speed): | (average 18 dishes per rack) |
Table to Table connection: | 66″ (1676 mm) |
Number of Tanks: | 1 |
Height with door open: | |
Charging hole size (width): | |
Charging hole size (height): | |
Net weight: | 1012 lb (459 kg) |
Shipping weight: | 1210 lb (549 kg) |
Shipping width: | |
Shipping depth: | |
Shipping height: | |
Shipping volume: | 143 cu.ft (4.05 m3) |
Noise level: | <70 dBA |
Unit predisposed to accept external detergent dispensers, detergent probes and rinse aid dispensers.
Exhaust Requirements
Unit supplied as standard with extended vent hoods (can be removed during installation if not required). Exhaust extraction not more than 177 CFM (300 m³/h) Refer to installation diagram for minimum exhaust hood installation height .