Venting

The hood is more effective when used in the extraction mode (ducted to the outside).

Venting kits may be purchased through your retailer or DIY store, and must be ducted to an outside vent of 125mm (5”).

The 120125mm collar should be fitted onto the ducting spigot to suit UK diameter ducting, and held in position by a jubilee clip (not supplied) used to secure the flexible hose.

Where flexible duting is fitted the length should be no more than:

3 metres with one 90º bend, or 2metres with two 90º bends.

Bends of more than 90º will reduce the efficency of the hood and reduce airflow.

The ducting used must be manufactured from fire retardent material conforming to the relevant British Standard or DIN 4102- B1.

When the cooker hood is ducted to the outside the charcoal filters must be removed.

Recirculation

If you are using the hood for recirculation, ensure the charcoal filters are in position following the instructions contained in the section “To Remove/ Replace the Charcoal Filters”.

Note: When the hood is used in the recirculation mode ensure that the plate (T) has been fixed into the lower chimney section. If not, fit the plate as illustrated opposite using two of the self tapping screws provided in the fixing kit.

14

Image 14
Contents Instruction Book Maintenance and Cleaning For the User For the InstallerImportant Safety Information Service Force CentresChild Safety Important Safety InformationInstallation Maintenance and ServiceCooker Hood Controls Your ApplianceOperating Instructions Worktop LightingExtraction To OperateRecirculation Metal Grease Filters Maintenance and CleaningExternal Cleaning Remove the metal grease filters one at a time byChanging the Light Bulb Charcoal FiltersTo Remove/Replace the Charcoal Filters Something not Working Service and Spare PartsSymptom Solution Guarantee Conditions ExclusionsElectrical Requirements Installation InstructionsElectrical Connections Electrical ConnectionUnpacking Installing the Cooker HoodInstallation Requirements Clearance Height Fitting the Wall BracketsFitting the Canopy Hood Venting Fitting the Chimney Stack Page Page Page Page Berkshire SL1 1DZ