Wiring Diagram
A. IGNITOR SWITCH
B. IGNITOR UNIT
Commissioning
When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below.
1.Turn the gas tap to the MAX position and ignite.
2.Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below.
Procedure:
1. |
| |
2. | Remove the control knob. |
|
3. | To adjust, use a thin bladed screwdriver |
|
| and turn the adjustment screw (it may be |
|
| located inside the gas tap shaft or on the |
|
| body of the gas tap itself, according to |
|
| different models - see diagram). Adjust the |
|
| minimum gas flow level until the flame is |
|
| steady and does not extinguish, when the |
|
| knob is turned from MIN to MAX. Repeat | Minimum adjustment screw |
| this procedure for all burners. |
|