Electrolux ER 8126 B Something not Working, Symptom Solution, Low room temperature operation

Page 11

SOMETHING NOT WORKING

Important: If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use or installation a charge will be made, even if the appliance is under guarantee.

Before contacting your local Service Force Centre, check the following points:

Symptom

Solution

 

 

No power to the appliance

Check there is power at the socket.

 

 

 

Check there is not a power cut by checking the

 

household lights.

 

 

 

Check the fuse has not blown.

 

 

The light does not come on

Ensure that the bulb is correctly fitted.

 

 

 

Replace the bulb if it has blown.

 

 

 

Check the door light switch is not jammed.

 

 

The temperature in the fridge or freezer section is

Check the thermostat control knob in the fridge is

too high

turned to the correct setting relative to ambient

 

conditions.

 

 

 

Check the ambient temperature is within the

 

appliance’s operating limits of 10°C to 32°C.

 

Relocate the appliance if necessary.

 

 

The freezer door will not open

Has door just been opened? If so leave for a few

 

minutes to allow the air pressure to equalise.

 

 

The compressor runs continously

Adjust the thermostat control knob to give correct

 

temperature control. See “Setting the temperature”.

 

 

 

Check that the doors are closed.

 

 

 

Large quantities of food have recently been placed in

 

the cabinet and/or door is frequently opened.

 

 

 

Check that air ventilation is not obstructed.

 

 

Excessive frost and ice has built up

Ensure the doors are not left open.

 

 

 

Check that nothing is preventing the doors from

 

closing.

 

 

 

Is the door gasket intact and clean.

 

 

 

Has advised periodic defrosting been carried out.

 

 

Noise

Refer to normal operating sounds.

 

 

Water under the salad bin

Check the drain hole is not blocked. (see

 

Maintenance and Cleaning).

 

 

Low room temperature operation

During prolonged periods of low room temperatures,ie;10°C and lower, the compressor on single compressor fridge freezer can remain inoperative during this time .

This is due to the air temperature within the refrigerator compartment being maintained at 6°C or under thus not calling the thermostat to energise the compressor .

11

Image 11
Contents Instruction Book Important Safety Information Contents Description of the Appliance Freezer compartment Before usingSetting the temperature OperationFresh food refrigeration Frozen food storageThawing Making ice cubesPositioning the door shelves Movable shelvesHealth and Safety Guidelines Refrigerator Maintenance and CleaningExternal cleaning DefrostingFreezer Something not Working Symptom SolutionLow room temperature operation 7 0 5 9 2 9 9 2 Service and Spare PartsCustomer Care Department Exclusions Guarantee ConditionsStandard guarantee conditions European GuaranteeNET Capacity Technical SpecificationsRear spacers InstallationPositioning Green and Yellow Earth Blue- Neutral Brown- Live Electrical connectionsDoor reversal directions Page Page Electrolux plc