GB
| Instructions for the Installer | ||
Technical data |
|
|
|
|
|
|
|
Model |
| A 75108 GA3 |
|
|
|
|
|
Gross capacity (l) |
| 100 |
|
Net capacity (l) |
| 80 |
|
Width (mm) |
| 595 |
|
Height (mm) |
| 850 |
|
|
|
|
|
Depth (mm) |
| 635 |
|
|
|
|
|
Energy consumption | (kWh/day) | 0,575 |
|
| (kWh/year) | 210 |
|
Energy class, according to EU Standards | A |
| |
Freezing capacity (kg/24h) |
| 9 |
|
Rising time (h) |
| 13 |
|
Rated current (A) |
| 0.5 |
|
Weight (kg) |
| 40 |
|
Installing the appliance
Transportation, unpacking
It is recommended to deliver the appliance in its original packaging, in a vertical position.
After each transportation the appliance must not be switched on for approx. 2 hours.
Unpack the appliance and check if there are damages on it. Report possible damages immediately to the place of purchase. In which case retain packaging.
Cleaning
Remove any adhesive tape, which ensure the parts do not move in the appliance.
Wash the inside of the appliance using lukewarm water and mild detergent. Use soft cloth.
After cleaning wipe out the inside of the appliance.
Placement
The ambient temperature has an effect on the energy consumption and proper operation of the appliance. When placing, take into consideration that it is practical to operate the appliance between ambient temperature limits according to the climate class that is given in the chart below and can be found in the rating plate.
When placing the appliance ensure that it stands level. This can be achieved by the two adjustable feet (1) bottom front two.
2 |
1 |
of the adjustable feet. When levelling the appliance if necessary, these washers can be removed.
Do not stand the appliance on a sunny place or close to a radiator or cooker.
The refrigerator is designed to operate when it is totally pushed to the wall.
When placing the refrigerator keep minimal distances recommended in figure.
A: placing it under a
B: placing it freely
Class of climate | Ambient temperature |
SN | +10 ... +32 °C |
N | +16 ... +32 °C |
ST | +18 ... + 38 °C |
If the ambient temperature goes below the lower data the temperature of the cooling compartment can go beyond the prescribed temperature.
If the ambient temperature goes beyond the upper data this means longer operating time of the compressor, increasing temperature in the freezer or increasing energy consumption.
8