Electrolux A 75100 GA3 Change of door opening direction, Electrical Connection

Page 9

Change of door opening direction

Should the setting-up place or handling demand it, door- opening direction can be refitted from the right hand side to the left hand side.

Following operations are to be done on the basis of figures and explanations:

Pull out the plug from the mains socket.

Tilt back the appliance carefully so that the compressor can not touch the floor. It is recommended to ask another person for help, who can keep the appliance at this position safely.

Unscrew the adjustable feet situated on both sides (2 pieces), in addition the screws fixing the lower door holders (3 pieces) respectively the screw on the other side.

Take off the freezer door by pulling it slightly downwards.

Unscrew the top door hinge pin of the refrigerator then screw it back on the other side.

Fit the freezer door on the upper door hinge pin.

Insert over the pin in the lower door holding plate in the direction of the arrow.

Fix the plate on the other side leaving the position of the door unchanged.

GB

Then screw in the one screw in the place set free on the other side as well as the adjustable feet (2 pieces) and stand upright again.

Place over the handles on the other side and put the plastic covering pins supplied in the plastic bag of this instruction book into the vacant holes.

Place the appliance back into its location, set it level and plug it into the mains socket.

In case you do not want to perform the procedures above, call your nearest Service Force Centre. Technicians will accomplish the refitting expertly for a charge .

Electrical Connection

Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person. This appliance

must be earthed.

The manufacturer declines any liability should these safety measures not be observed.

Electrical Requirements

Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance rating plate.

The appliance is supplied with a 13 amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13 amp ASTA approved (BS 1362) fuse must be used. Should the plug need to be replaced for any reason. The wires in the mains lead are coloured in accordance with the following code:

Green and Yellow:

Earth

Blue:

Neutral

Brown:

Live

The wire coloured green and yellow must be connected to the terminal marked with the letter “E“ or by the earth

symbol or coloured green and yellow.

The wire coloured blue must be connected to the terminal “N“ or coloured black. The wire coloured brown must be connected to the terminal marked “L“ or coloured red.

9

Image 9
Contents 75100 GA3 Contents General safety precautions Important safety informationPrecautions for child safety Safety precautions for installationInstructions for the User General safety precautionsGeneral information Packing consists of reusable materials onlyInstallation Switches and indicatorsAdjusting the temperature Handling the applianceMaintenance Regular cleaning Power or operation failureLong-term absence Installing the appliance Change of door opening direction Electrical ConnectionElectrical Requirements Noises During Operation Regulations, Standards, GuidelinesTechnical Terminology Storage time of deep-frozen and frozen products Storage time chartService and Spare Parts Customer Care Department0870 5 European Guarantee Standard guarantee conditionsThis guarantee does not cover ExclusionsAE/4 Page From the Electrolux Group. The world’s No.1 choice