Instructions for the Installer
Technical Data
APPLIANCE GAS SUPPLY: Natural Gas G20 20mbar
APPLIANCE CATEGORY:II 2H3+
Cabinet Dimensions
Minimum aperture height | 580 mm |
Minimum aperture depth | 550 mm |
Minimum aperture width | 560 mm |
Oven
Grill Element | 1,827 W |
Oven burner | 2,700 W (Natural gas) |
| 2,500 W (LPG) |
Oven light | 25 W |
Cooling fan | 25 W |
Total rating | 1,880 W |
Supply voltage (50 Hz) |
Important Safety Requirements
This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations (current addition) and the I.E.E. Wiring Regulations. Detailed recommendations are contained in the following British Standard Codes of Practice - B.S. 6172, B.S. 5440: Part 2 and B.S. 6891: Current Editions.
Provision for Ventilation
This appliance is not connected to a combustion products evacuation device. It shall be installed and connected in accordance with the current installation regulations. Particular attention shall be given to the relevant requirements regarding ventilation.
The room containing the appliance should have an air supply in accordance with BS. 5440: Part 2 Current Edition. All rooms require an openable window or
equivalent and some rooms will require a permanent vent as well. For room volumes up to 5m3 an air vent 100cm2 is required; for room volumes between 5m3 and 10m3, an air vent with a minimum area of 50cm2 is required. If the room has a door which opens directly to the outside, no air vent is required. For room volumes that exceed 11m3 no air vent is required.
If there are other fuel burning appliances in the same room, B.S. 5440: Part. 2: Current Editions should be consulted to determine the requisite air vent requirements.
Prolonged intensive use of the appliance may call for additional ventilation, for example opening a window, or more effective ventilation, for example increasing the level of mechanical ventilation where present.
Building in |
|
Location of appliance |
|
The appliance may be located in a kitchen, a kitchen/ |
|
diner or bedsitting room but not in a bathroom, shower |
|
room or bedroom. |
|
It is essential that there is a minimum clearance of 3mm |
|
between the top surface of the appliance and the inside |
|
top of the cabinet. The unit must be fitted into a cabinet |
|
conforming to Fig.2. |
|
This oven unit may be used in a |
|
situation (see relevant diagrams). If the appliance is to |
|
be |
|
installed before the oven unit. | Fig.1 FO 0374 |