Viking D3 manual Wall Construction, Ground, Receptacle, Opening for, Power Cord

Page 2

2 Wall Construction

This Built-in Microwave Hood should be mounted against and supported by a flat vertical wall. The wall must be flat for proper installation. If the wall is not flat, use spacers to fill in the gaps. Wall construction should be a minimum of 2” x 4” wood studding and 3/8” or more thick dry wall or plaster/lath. The mounting surfaces must be capable of supporting a weight of 110 pounds—the oven and contents—AND the weight of all items which would normally be stored in the top cabinet above the unit. The unit should be attached to a minimum of one 2” x 4” wall stud.

To find the location of the studs, one of the following methods may be used:

Use a stud finder, a magnetic device which locates the nails in the stud.

Use a hammer to tap lightly across the mounting surface to find a solid sound. This will indicate stud location.

The center of the stud can be located by probing the wall with a small nail to find the edges of the stud and then placing a mark halfway between the edges. The center of any adjacent studs will normally be 16” or 24” to either side of this mark.

3Electrical Grounding

Instructions

This appliance must be grounded. This oven is equipped with a cord having a grounding wire with a grounding plug. It must be plugged into a wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local codes and ordinances. In the event of an electrical short circuit, grounding reduces risk of electric shock by providing an escape wire for the electric current.

WARNING: Improper use of the grounding plug can result in a risk of electric shock.

Electrical Requirements

The oven is equipped with a 3-prong grounding plug. DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE GROUNDING PIN FROM THE PLUG.

DO NOT USE AN EXTENSION CORD.

If the power supply cord is too short, have a qualified electrician or serviceman install an outlet near the appliance.

The Power Supply Cord and plug must be connected to a separate 120 Volt AC, 60 Hz, 15 Amp, or more branch circuit, single grounded receptacle. The receptacle should be located inside the cabinet directly above the Built-in Microwave Hood mounting location as shown in figure 2.

NOTE:

If you have any questions about the grounding or electrical instructions, consult a qualified electrician or serviceperson.

Neither Viking nor the dealer can accept any liability for damage to the oven or personal injury resulting from failure to observe the correct electrical connection procedures.

figure

Ground

Receptacle

 

 

*Opening for

 

Power Cord

IMPORTANT: * Power cord opening for metal cabinets: Deburr opening to remove rough edges.

Radio or TV Interference

Should there be any interference caused by the Built-in Microwave Hood to your radio or TV, check that the oven is on a different electrical circuit, relocate the radio or TV as far away from the oven as feasible or check position and signal of receiving antenna.

E2

Image 2
Contents Mounting Space IMPORTANT-Please Read and FollowUnpacking and Examining Your Oven Front Street Greenwood, Mississippi 38930 USAGround Power CordWall Construction ReceptacleHood Exhaust Duct Tools Recommended for Installation Installation HardwareHorizontal Exhaust Outside Preparation of the OvenVentilation System Preparing Rotate 90˚ Vertical Exhaust OutsideSave fan cover bracket for Mounting Plate Oven InstallationMounting Scale Plate Scale Plates Mounting PlateMounting Oven to the Wall Checklist for Installation Bottom PlateEspace de Support IMPORTANT-S’il vous plaît lisez et suivezDéballage et Examen de Votre Four Le cordon Construction du MurTerre Matériel d’installation SchémaRecirculation d’air Préparation du fourSystème de Ventilation Échappement HorizontalÉchappement Vertical Ventilation ExtérieurePlaque de montage Installation du FourMontage de Plaque Graduée Montage Mural du Four Pense-bête pour l’installation Espacio de Montaje Importante-Por favor lea y sigaDesempaque y Revisión de su horno Conectado Construcción de la ParedTomacorriente TierraHerrajes de Instalación Elem Nombre CantEscape Horizontal Extracción hacia Preparación del hornoSistema de Escape Preparación del horno para InstalaciónEscape Vertical Extracciòn hacia el exterior Gire 90˚Placa de Montaje Instalación del HornoMontaje de las Placa de Escala AnclajePared Montaje del Horno en la ParedDe pared Lista de verificación para Instalación