® 30" and 36" Traditional Series Vented and Non- Vented
Range Hoods
PRODUCT MODEL NUMBERS
KHTU160K
OVERALL DIMENSIONS
KHTU100K
Electrical:
Note: Underside of hood must be a minimum of 24" (61 cm) from cooking surface.
(8.1 cm)
(34.0 cm)
(12.1 cm)
(6.5 cm)
(3.0 cm)
(12.9 cm)
(25.0 cm)
(45.1 cm)
(4.0 cm)
(19.6 cm)
(4.4 cm)
(4.6 cm) Do not use these
knockouts
30" (76.2 cm) 36" (91.4 cm)
VENTING REQUIREMENTS
(8.3 cm x 25 cm) vent through the roof
Roof venting
Recommended standard fittings
(8.3 cm x 25 cm) vent through the wall
Wall venting
(8.3 cm x 25 cm) 90° elbow
= 5 ft. (1.5 m)
(8.3 cm x 25 cm) flat elbow
= 12 ft. (3.7 m)
(8.3 cm x 25 cm) wall cap
= 0 ft. (0 m)
Recommended vent system length
Use 3 1/4" x 10" (8.3 cm x 25 cm) vent with maximum length of
26 feet (8 m) for vent system. For best performance, use no more than three 90° elbows. To calculate the length of system you need, add the equivalent feet (meters) for each vent piece used in the system. See the following example.
wall | |||||||||||||||
cap | |||||||||||||||
|
|
|
|
|
|
| vent system |
| |||||||
|
|
|
|
|
| wall | |||||||||
|
| (8.3 cm x 25 cm) |
|
|
|
| |||||||||
|
|
|
|
|
| cap | |||||||||
|
| 90° elbow |
|
|
|
| |||||||||
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| 6 ft. (1.8 m) |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| 3 ft. |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
| (0.93 m) |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Maximum length | = 26 ft. | (8 m) | |||||||||||
|
| 1 — 90° elbow | = |
| 5 ft. | (1.5 m) | |||||||||
|
| 9 ft. (2.8 m) straight | = |
| 9 ft. | (2.8 m) | |||||||||
|
| 1 — wall cap | = |
| 0 ft. | (0 m) | |||||||||
|
| Length of |
|
|
|
|
| ||||||||
|
| (8.3 cm x 25 cm) |
|
|
|
|
| ||||||||
|
| system | = 14 ft. | (4.3 m) |
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. 8284977 |