® 30" Freestanding and Slide-In Dual Fuel Range
PRODUCT MODEL NUMBERS
KDRS807S KDSS907S
Gas supply: Provide a gas supply line of 3/4"
PRODUCT DIMENSIONS
Freestanding Range | Slide-in Range |
(1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON® tape. With LP gas, piping or tubing size
can be 1/2" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system. If local codes permit, a new CSA design-certified, 4' - 5' (122 - 152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line. A 1/2" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator. The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range. It should be in a location that allows ease of opening and closing.
27-1/4"
(69.2 cm) max. from handle to standoff at back of range**
36" (91.4 cm) cooktop trim height with leveling legs screwed all the way in*
41-3/4"
(106 cm) overall height with leveling legs screwed all the way in*
Model/serial number plate (located on the right-hand side oven door trim)
23" (58.4 cm) countertop notch to rear of countertop
27-1/4" | 30" |
(69.2 cm) max. | (76.2 cm) |
from handle to | |
standoff at | |
back of range** | |
35-5/8" (90.5 cm) height to underside of cooktop edge with leveling legs screwed all
the way in*
Model/serial number plate (located on the right-hand side oven door trim)
Electrical: When a 4-wire or 3-wire, single phase 120/240 volt, 60 Hz, AC only electrical supply is available, a 50-amp maximum circuit protection is required. When a 4-wire or 3-wire single phase 120/208 volt 60 Hz, AC only electrical supply is available, a 40-amp maximum circuit protection is required, fused on both sides of the line. A separate circuit is recommended. A time-delay fuse or circuit breaker is recommended.
*Range can be raised approximately 1" | *Range can be raised approximately 1" |
(2.5 cm) by adjusting the leveling legs. | (2.5 cm) by adjusting the leveling legs. |
**When installed in a 24" (61 cm) base cabinet | **When installed in a 24" (61 cm) base cabinet |
with 25" (63.5 cm) countertop; front of oven | with 25" (63.5 cm) countertop; front of oven |
door protrudes 1" (2.5 cm) beyond 24" | door protrudes 1-3/4" (4.4 cm) beyond |
(61 cm) base cabinet. | 24" (61 cm) base cabinet. |
SLIDE-IN COUNTERTOP PREPARATION
30"
(76.2 cm)³⁄₈"
(1.0 cm)
30 ¾"
(78.1 cm)
INSTALLATION CLEARANCES
The cooktop sides of the slide-in range fit over the cutout edge of your countertop.
If you have a square finish (flat) countertop and the opening width is 30" (76.2 cm), no countertop preparation is required.
Formed front-edged countertops must have molded edge shaved flat 3/8" (1.0 cm) from each front corner of opening.
Tile countertops may need trim cut back
3/8" (1.0 cm) from each front corner and/or rounded edge flattened.
If countertop opening width is greater than
30" (76.2 cm), adjust the 3/8" (1.0 cm) dimension.
Countertop must be level. Place level on countertop, first side to side; then front to back. If countertop is not level, range will not be level. Range must be level for satisfactory baking conditions.
| Freestanding Ranges | | | | Slide-In Ranges | |
| 13" (33 cm) upper | For minimum | | | 13" (33 cm) max. | For minimum |
| clearance to top | | | clearance to top |
| cabinet depth | of the cooktop, | | upper cabinet depth | of the cooktop, |
| 30" (76.2 cm) min. | | see NOTE. | | | 30" (76.2 cm) min. | | see NOTE. |
| | | | | | |
| opening width | | | | | opening width | | |
18" (45.7 cm) | | | | 18" (45.7 cm) | | | 22-15/16" (58.3 cm) |
| | | | 3/4" (1.9 cm) | opening depth |
upper cabinet | 30" (76.2 cm) | | | upper cabinet | | | |
to countertop | min. opening | | | to countertop | | radius both corners | |
| width | | | | | 30" (76.2 cm) | |
| | | | | | min. opening | |
| | | | | | width | |
| | This shaded area | Cabinet door | | | | This shaded area | Cabinet door |
| | 5" (12.7 cm) min. | | 6" | recommended | or hinge |
| 8" | recommended | or hinge | |
5" (12.7 cm) min. | clearance from | | (15.2 cm) | for installation | should not |
(20.3 cm) | for installation | should not | |
clearance from | extend into | both sides of the | | | of outlet or | extend into |
both sides of the | | of outlet or | range to the side | 6" | | junction box. | the cutout. |
8" | junction box. | the cutout. | | |
range to the side | | | wall or other | (15.2 cm) | | |
wall or other | (20.3 cm) | | | combustible | | 7" (17.8 cm) | | |
combustible | 7" (17.8 cm) | 4-1/2" | | material. | | 4-1/2" | |
material. | | | | | (11.4 cm) | |
| | (11.4 cm) | | This shaded area | | | | |
This shaded area | | | | | | | |
| | | recommended for | | | Available | |
recommended for | | | | installation of | | 1-1/2" | |
installation of | 1-1/2" | Available | | rigid gas pipe. | | (3.8 cm) | area for | |
rigid gas pipe. | (3.8 cm) | area for | | | | | gas and | |
| | 4-1/2" | | electric | |
| | gas and | | | |
4-1/2" | | electric | | (11.4 cm) | | installation. | |
(11.4 cm) | installation. | | | | | | |
NOTE:
24" (61 cm) minimum when bottom of wood or metal cabinet is protected by not less than 1/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet.
If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. W10154991 |
Instructions packed with product. Specifications subject to change without notice. | 06-24-08 |