| ® | Gas | |||||||||
|
|
|
|
|
| ||||||||
PRODUCT MODEL NUMBERS |
|
| OVERALL DIMENSIONS | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
KGCC506R | KGCC766R |
|
| Metal Cooktops | |||||||||
KGCC566R | KGCV566R |
|
| ||||||||||
|
|
|
|
|
|
|
|
|
| ||||
KGCC706R |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| ||
Gas Supply: This cooktop is factory set for use |
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
| ||||||
with Natural gas. Cooktop can be converted to LP |
|
|
|
|
|
|
|
| |||||
gas. Provide a gas supply line of ³⁄₄" (1.9 cm) rigid |
|
|
|
|
|
|
|
| |||||
pipe to the cooktop location. A smaller size pipe on | A |
|
| ||||||||||
| |||||||||||||
| |||||||||||||
longer runs may result in insufficient gas supply. |
|
|
|
|
| C | |||||||
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
| ||||||
gas must be used. Do not use TEFLON® tape. With |
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
| ||||||
LP gas, piping or tubing size can be ¹⁄₂" minimum. |
| A. 21¹⁄₄" (53.4 cm) | |||||||||||
Usually, LP gas suppliers determine the size and |
| ||||||||||||
materials used in the system. |
|
|
| B. 31⁷⁄₁₆" (79.8 cm) on 30" (76.2 cm) models, | |||||||||
Electrical: A 120 volt, 60 Hz., AC only, |
| 37⁹⁄₁₆" (95.4 cm) on 36" (91.4 cm) models | |||||||||||
| C. 2⁷⁄₈" (7.3 cm) | ||||||||||||
fused, electrical circuit is required. A |
|
|
|
|
|
|
|
| |||||
fuse or circuit breaker is also recommended. It is | |||||||||||||
recommended that a separate circuit serving only |
|
|
|
|
| ||||||||
|
|
| B | ||||||||||
this cooktop be provided. |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| A |
|
|
|
|
| C |
|
|
| A. 20⁵⁄₁₆" (51.5 cm) |
|
CABINET OPENING DIMENSIONS |
| B. 30³⁄₁₆" (76.8 cm) on 30" (76.2 cm) models, |
| |
| 36⁷⁄₁₆" (92.5 cm) on 36" (91.4 cm) models |
| ||
|
|
|
| |
|
|
| C. 2⁷⁄₈" (7.3 cm) |
|
| A |
|
|
|
|
|
| D |
|
|
|
| B |
|
C | B |
|
|
|
|
|
|
| |
|
|
| A | C |
|
|
|
| |
K | F |
| G |
|
E |
|
|
| |
M |
|
|
|
|
|
|
| A. 21¹⁄₈" (53.7 cm) |
|
|
|
| B. 30⁵⁄₁₆" (77.0 cm) on 30" (76.2 cm) models, |
|
|
| H | 36⁵⁄₁₆" (92.3 cm) on 36" (91.4 cm) models |
|
| L | C. 2⁷⁄₈" (7.3 cm) |
| |
|
|
| ||
J | I |
|
| |
|
|
| ||
|
|
| F. 19" (48.3 cm) |
|
A. 30" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform and bottom of unprotected wood or metal cabinet (24" [61 cm] minimum clearance if bottom of wood or metal cabinet is protected by not less than ¹⁄₄" [0.6 cm] flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel, or
0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper) D. 13" (33 cm) maximum upper cabinet depth
E. 2¹⁄₈" (5.4 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop within minimum horizontal clearances to cooktop
H. Grounded outlet - Locate within 24" (61 cm) of right rear corner of cutout
I. 29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" models
J. 8³⁄₈" (21.3 cm) minimum distance to nearest left and right side combustible surface
K. 2⁷⁄₈" (7.3 cm) minimum distance to rear combustible surface
L. Gas line opening - Wall: anywhere 5" (12.7 cm) below underside of countertop. Cabinet floor: anywhere within 6" (15.2 cm) of rear wall is recommended
M. 24" (61 cm) minimum countertop depth is required
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. 8286304 |
Instructions packed with product. Specifications subject to change without notice. |