Hotpoint HD 6, HS 9, HS 7, HTC 6, HS 6, HTC 9, HD 7 General, Safety precaution, Electric Connection

Page 6

General

GB

General

Carefully read the following important information regard- ing installation safety and maintenance.

Keep this information booklet accessible for further con- sultations.

The appliance has been designed for use in the ducting version (air exhaust to the outside – Fig.1B), filtering ver- sion (air circulation on the inside – Fig.1A).

Safety precaution

1.Take care when the cooker hood is operating simul- taneously with an open fireplace or burner that depend on the air in the environment and are supplied by other than electrical energy, as the cooker hood removes the air from the environment which a burner or fireplace need for combustion.

The negative pressure in the environment must not exceed 4Pa (4x10-5 bar).

Provide adequate ventilation in the environment for a safe operation of the cooker hood. Follow the local laws applicable for external air evacuation.

Before connecting the model to the electricity net- work:

-control the data plate (positioned inside the appliance) to ascertain that the voltage and power correspond to the network and the socket is suitable. If in doubt ask a qualified electrician figure 1C.

-If the power supply cable is damaged, it must be replaced with another cable or a special assembly, which may be obtained direct from the manufacturer or from the Techni- cal Assistance Centre.

-This device must be connected to the supply network through either a plug fused 3A or hardwired to a 2 fase spur protected by 3A fuse.

2. Warning!

In certain circumstances electrical appliances may be a danger hazard.

A)Do not check the status of the filters while the cooker hood is operating

B)Do not touch bulbs or adjacent areas, during or straight after prolonged use of the lighting installation.

C)Flambè cooking is prohibited underneath the cooker hood

D)Avoid free flame, as it is damaging for the filters and a fire hazard

E)Constantly check food frying to avoid that the overheated oil may become a fire hazard

F)Disconnect the electrical plug prior to any mainte- nance.

G)This appliance is not intended for use by young

children or infirm persons without supervision

H)Young children should be supervised to ensure they do not play with the appliance

I)There shall be adequate ventilation of the room when the rangehood is used at the same time as ap- pliances burning gas or other fuels

L)There is a risk of fire if cleaning is not carried out in accordance with the instructions

This appliance conforms to the European Directive EC/2002/96, Waste Electrical and Electronic Equipment (WEEE). By making sure that this appliance is disposed of in a suitable manner, the user is helping to prevent potential damage to the environment or to public health.

The symbol on the product or on the accompanying paperwork indicates that the appliance should not be treated as domestic waste, but should be delivered to a suitable electric and electronic appliance recycling collection point. Follow local guidelines when disposing of waste.

For more information on the treatment, re-use and recycling of this product, please contact your local authority, domestic waste collection service or the shop where the appliance was purchased.

Installation instructions

Assembly and electrical connections must be carried out by specialised personnel.

• Electric Connection

The appliance has been manufactured as a class II, therefore no earth cable is necessary.

The connection to the mains is carried out as follows: BROWN = L line

BLUE = N neutral

If not provided, connect a plug for the electrical load indi- cated on the description label. Where a plug is provided, the cooker hood must be installed in order that the plug is easily accessible. An omnipolar switch with a minimum opening of 3mm between contacts, in line with the electri- cal load and local standards, must be placed between the appliance and the network in the case of direct connection to the electrical network.

The minimum distance between the support surfaces of the cooking pots on the cooker top and the lowest part of the cooker hood must be at least 65 cm. If a connec- tion tube composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the cooker hood exhaust to the same conductor used to circulate hot air or for evacuating fumes from other appli- ances generated by other than an electrical source. Before proceeding with the assembly operations, remove the anti-

8

Image 6
Contents Models HTC 6 HTC Max 90 cm HTC D E a Use and maintenance Installation 4 GeneralSafety precaution Installation instructions User instructionsGeneral Safety precautionBefore connecting the model to the electricity net- work Electric ConnectionFixing to the wall Use and maintenancePlease note Fixing the decorative telescopic flueReplacing halogen light bulbs Fig