Hotpoint HHP7.5CM, HHP9.5CM, HHP6.5CM(WH) operating instructions GB Pyramid controls

Page 10

GB PYRAMID controls

Models with mechanical keypad

HHP7.5CM

HHP6.5CM

HHP9.5CM

HHC6.7AM(WH)

HHC6.7AM(BK)

T1 T2 T3 T4 T5

T1 Motor reset

Pressing the button while the hood is in operation turns it OFF.

T2 Speed 1

Pressing the button sets the hood to speed 1.

T3 Speed 2

Pressing the button sets the hood to speed 2.

T4 Speed 3

Pressing the button sets the hood to speed 3.

T5 Lights ON/OFF

Models with soft button keypad

(Only available in certain models)

B

T1 T2 T3 T4 T5 T6

T1 Motor reset

Pressing the button while the hood is in operation turns it OFF.

T2 Speed 1

Pressing the button sets the hood to speed 1.

T3 Speed 2

Pressing the button sets the hood to speed 2.

T4 Speed 3

Pressing the button sets the hood to speed 3.

T5 Booster

Pressing the button sets the hood to high speed. After 5 minutes, the hood returns to the previous speed; pressing a speed button (T2, T3 or T4) quits booster mode and sets the selected speed.

T6 Lights ON/OFF

Grease/odour filter warnings

The T2 icon flashes to indicate that the grease filter is saturated, while T3 flashes to indicate that the odour filter is saturated, and if both are flashing then both filters are saturated. You must then clean/replace the grease filter (A) or odour filter (B) or both, accordingly (see “Maintenance and care”).

To reset the filter counter:

Hold down T4 for three seconds while the hood is on. The warning led flashes three times, then returns to its normal mode If both filter warnings are active at the same time, you must reset each separately.

The first sequence resets the grease filter, while the second sequence resets the odour filter.

Hood configuration:

To set the operating mode of the hood, hold down T5 for 6 seconds while the product is off. Icons T2 or T3 will light up to show the type of installation: T2 ventilation, T3 filtering. You can change the type of installation by pressing T4 cyclically.

To save the new configuration press T1 individually.

Models with soft button keypad and display

(Only available in certain models)

 

 

 

B

 

 

T1

T2

T3

T4

T5

T6

1 Motor ON/OFF

Press the button with the hood off to set speed 1. Pressing the button while the hood is in operation turns it OFF.

T2 Speed -

Pressing the button returns the hood to the previous speed.

T3 Speed +

Pressing the button returns the hood to the next speed. If the hood is off, pressing these buttons sets speed 1.

T4 Booster

Pressing this button sets the hood to high speed; the letter "b" flashes slowly on the display. After 5 minutes, the hood returns to its previous speed; this can also be done while booster mode is on by pressing either speed button (T2 or T3).

T5 Timer

Pressing this button delays the hood turning off automatically by 5 minutes. The timer counts down on the display in minutes. The timer can only be set for manual speeds, not for booster mode.

T6 Lights ON/OFF

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24

10

Image 10
Contents Operating Instructions Cooker Hood150mm 150-125mm Ø150mm 550 650 150 120 150 Page Page Electrical hook up InstallationTechnical data Filter or ducted?GB Pyramid controls Maintenance and care Troubleshooting Page Parts and Accessories GB After Sales ServiceHotpoint Service Essential Contact InformationExtended Guarantees Months Parts and Labour GuaranteeYear Parts Guarantee Free Helpdesk Service195107497.04