Electrical Connection
Electrical connection
Ovens with a
Two types of connection are provided:
Connection n° 1
Connecting the power supply cable to the mains.
Fit a normalized plug to the cable, which corresponds to the load indicated on the data plate; if the appliance is connected directly to the mains, an omnipolar circuit- breaker with a minimum opening of 3 mm between the contacts, suitable for the load indicated and complying with current directives, must be installed between the appliance and the mains (the earthing wire must not be interrupted by the
•the circuit breakers or fuses of the home system can support appliance load (see data plate);
•the power supply system has an efficient earthing connection which complies with the provisions of current regulations and the law;
•there is easy access to the socket or the omnipolar
N.B.: do not use reducers, adapters or shunts as these could cause heating or burning.
Connection n° 2
Disposing of the plug.
WARNING:THIS APPLIANCE MUST BE EARTHED. Ensure that before disposing of the plug itself, you make the pins unusable so that it cannot be accidentally inserted into a socket. Instructions for connecting cable to an alter- native plug:
Important: the wires in the mains lead are coloured in accordance with the following code:
Green & Yellow | |
Blue | |
Brown |
|
If the colours of the wires in the mains lead do not correspond with the coloured markings identifying the terminals in your plug, proceed as follows.
Connect Green & Yellow wire to terminal marked “E” or $ or coloured Green or Green & Yellow.
Connect Brown wire to terminal marked “L” or coloured Red. Connect Blue wire to terminal marked “N” or coloured Black. If a 13 amp plug (BS 1363) is used it must be fitted with a 13 amp fuse.
A 15 amp plug must be protected by a 15 amp fuse, either in the plug or adaptor or at the distribution board.If you are in any doubt about the electrical supply to your machine, consult a qualified electrician before use.
How to connect an alternative plug
The wires in this mains lead are coloured in accordance
with the following code: |
| |
BLUE |
| “NEUTRAL” (N) |
BROWN |
| “LIVE” (L) |
GREEN ANDYELLOW | “EARTH” (E) | |
|
|
|
GREEN & |
|
|
YELLOW |
|
|
BROWN | 13 amp fuse |
|
|
| |
BLUE |
| |
| CORD GRIP |
|
|
|
|
Disposing of the appliance
When disposing of the appliance please remove the plug by cutting the mains cable as close as possible to the plug body and dispose of it as described above.
The plug and socket must be easily accessible.