DeLonghi EC220 CD manual If something does not work…

Page 15

If something does not work…

Problem

Possible causes

Solution

 

 

 

Espresso coffee does not flow out

No water in the tank

Fill the water tank

 

 

 

 

The holes in the filter-holder are blocked

Clean the holes in the filter-holder spouts

 

 

 

 

The espresso boiler outlet is blocked

Carry out the cleaning operation as descibed

 

 

in the paragraph headed “Cleaning”

Espresso coffee drips from the edges of the

The filter-holder is inserted incorrectly

Attach the filter-holder correctly and turn it

filter-holder instead of through the holes

 

firmly until fully home

 

 

 

 

The espresso boiler gasket has lost elasticity

Obtain a replacement for the espresso boiler

 

 

gasket from your Service Centre. See enclosed

 

 

guarantee.

 

 

 

 

The holes in the filter-holder spout are blocked

Clean the holes in the spouts.

 

 

 

The espresso coffee is cold

The OK light for making espresso is not alight

Wait for the OK light to come on

 

at the time the coffee-dispenser button is

 

 

pressed

 

 

Pre-heating has not been carried out

Carry out the pre-heating operation as descri-

 

 

bed in the paragraph headed “Pre-heating”

 

 

 

 

The cups have not been pre-heated

Pre-heat the cups using hot water

 

 

 

Loud pump noise

The water tank is empty

Fill up the tank

 

 

 

 

The tank is improperly inserted and the valve

Put light pressure on the tank to open the

 

on its base is not open

valve on its base

The consistency of the coffee is thin and pale

The ground coffee is insufficiently tamped

Increase tamping of ground coffee

(it emerges rapidly from the spout)

 

 

The quantity of ground coffee is insufficient

Increase the amount of ground coffee

 

 

 

 

 

The coffee is too coarsely ground

Only use ground coffee designed for use with

 

 

espresso coffee machines

 

 

 

 

The ground coffee is not the correct type

Change the type of ground coffee used

 

 

 

The consistency of the coffee is thick and dark

The ground coffee has been tamped too firmly

Tamp the coffee less firmly

(it emerges slowly from the spout)

 

 

Too much ground coffee has been used

Reduce the quantity of ground coffee

 

 

The outlet of the espresso boiler is clogged up

Carry out the cleaning operation, as described

 

 

in the paragraph headed”Cleaning”

 

The filter is blocked

Carry out the cleaning operation, as described

 

 

in the paragraph headed”Cleaning”

 

 

 

 

The coffee is too finely ground

Only use ground coffee for espresso coffee

 

 

machines

 

The ground coffee is too fine, or is damp

Only use ground coffee for espresso coffee

 

 

machines and ensure it is not too damp

 

The ground coffee is not the correct type

Change the type of ground coffee powder

 

 

 

The milk does not froth when making a

The milk is not cold enough

Always use semi skimmed milk straight from

cappuccino

 

the refrigerator at 5°C

 

The cappuccino-nozzle is dirty

Clean the small holes in the cappuccino-nozzle

 

 

carefully, especially those indicated in the

 

 

diagram

15

Image 15
Contents EC220 CD Electrical connection Description Safety information Use in conformity with purpose First use Preheating Sec MAX Espresso with pods Cappuccino Hot water Regular cleaning Descaling Min Repeat If something does not work… De’Longhi Appliances Via Seitz Treviso Italia
Related manuals
Manual 16 pages 15.51 Kb