Zero Adjustment - Voltage

While monitoring the voltage between the positive output (+OUT) and common (-OUT), and with both ports open to atmosphere, the zero may be adjusted. For unidirectional pressure ranges, turn the zero adjustment screw until a reading of 0.050 VDC is achieved. For bidirectional pressure ranges set to 5 VDC.

Zero Adjustment - Current

While monitoring the current output with both ports open to atmosphere, the zero may be adjusted. For unidirectional pressure ranges, turn the zero adjustment screw until a reading of 4 mA is achieved. For bidirectional pressure ranges, set the zero to 12 mA.

Span Adjustment - Voltage

Span or full scale output adjustments should only be performed by using an accurate pressure standard (electronic manometer, digital pressure gage, etc.) with at least comparable accuracy as the PX2670 Series. With full scale pressure applied to the high pressure port, adjust span for full scale electrical output of 10.05 VDC.

Example 1: Unidirectional pressure range of 0 to 1” WC and 0.05 to 10.05 VDC output. Apply 1” WC to the high pressure port and adjust span as close as practical to 10.05 VDC.

Span Adjustment - Current

Span or full scale output adjustments should only be performed by using an accurate pressure standard (electronic manometer, digital pressure gage, etc.) with at least comparable accuracy as the PX2670 Series. With full scale pressure applied to the high pressure port, adjust span for full sale electrical output of 20mA.

Example 1: Unidirectional pressure range of 0 to 1” WC

Apply 1” WC to the high pressure port and adjust span as close as practical to 20 mA.

Example 2: Bidirectional pressure range of ± 5” WC

Apply 5” WC to the high pressure port and adjust span as close as practical to 20 mA.

Apply -5” WC to the high pressure port and adjust span as close as practical to 4 mA.

Figure 4

Loop Power Supply

vs.

Loop Resistance for 4 to 20mA Transmitters

(Ohms)

800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Resistance

 

 

 

 

 

 

 

Operating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loop

 

 

 

 

 

 

 

 

Range

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

30

 

 

 

 

 

 

Loop Supply Voltage (Vdc)

Image 5
Contents User’s Guide OMEGAnet On-Line Service Internet e-mail Info@omega.com Voltage Current Position EffectFittings MountingZero Adjustment Current Zero Adjustment VoltageSpan Adjustment Voltage Span Adjustment CurrentWARRANTY/DISCLAIMER Temperature

PX2670 specifications

The Omega Engineering PX2670 is a high-performance pressure transducer that caters to a wide array of industrial applications. Known for its reliability and precision, the PX2670 seamlessly integrates into various systems, ensuring accurate pressure measurements under diverse conditions.

One of the standout features of the PX2670 is its robust construction. The device is designed to withstand harsh environments, making it suitable for industries such as oil and gas, pharmaceuticals, and food processing. With a stainless steel housing, the PX2670 offers excellent resistance to corrosion and can operate in extreme temperatures, enhancing its durability and longevity in demanding situations.

The PX2670 utilizes advanced sensing technologies, which contribute to its impressive accuracy and repeatability. It boasts a high overpressure capability, ensuring that it can handle spikes in pressure without compromising measurement integrity. This is particularly important in dynamic systems where pressure fluctuations can be common. The device’s wide pressure range, from vacuum levels to several thousand psi, allows for versatility in application, catering to both low and high-pressure environments.

Another notable characteristic of the PX2670 is its output options. The transducer can be configured to provide analog signals, such as 4-20 mA and 0-10 V, which are standard in process control systems. This flexibility enables easy integration into existing setups, facilitating quick installation and deployment.

The PX2670 also features a highly responsive performance with minimal hysteresis, ensuring that the readings are consistently precise. Additionally, it is equipped with temperature compensation technology, which helps maintain accuracy across varying thermal conditions, a common challenge in pressure measurement.

Safety and compliance are also paramount in industrial settings, and the PX2670 meets various international standards, ensuring it adheres to regulations for quality and safety.

In summary, the Omega Engineering PX2670 is a highly efficient, versatile, and reliable pressure transducer. With its durable construction, advanced sensing technology, a broad range of output options, and excellent temperature compensation, it stands out as a prime choice for professionals seeking precise pressure measurement solutions in challenging environments.