Wegener Communications Unity Satellite Receiver Model Unity Synchronous Data Option From Terminal

Page 3

2.2 Customer Premises Wiring

Outputs supplied on two RJ45 jacks. Pins are numbered (left-to-right) 1 to 8 as seen from the open end with tab facing downward.

PIN#

LVDS SIGNAL

RS422 SIGNAL

 

OUTPUT

OUTPUT

 

 

 

1

GND

GND

2

LD+

RD+

3

LD-

RD-

4

LS+

RS+

5

LS-

RS-

6

LC+

RC+

7

LC-

RC-

8

GND

GND

Table 1. RJ-45 Pin-outs

3. CONTROL AND STATUS INDICATIONS

Note: Sync Data option card may be setup by your network and local control may be disabled. If so, only the status monitoring will be possible.

3.1From Terminal

ŸSync data card setup with local control disabled:

The sync data card setup cannot be accessed via the terminal with local control disabled. Local control will have to be authorized by the network.

ŸSync data card setup with local control enabled : CSD cmd param port

Cmd: R - Set RS422 output state L - Set LVDS output state

D - Set data rate

P - Set PID

Param:E/D - Enable/disable output ports (used with R & L commands)

64.0- 6875 Kbps - data rate range (used with D command) 0x0020 - 0x1FFE - PID range (used with P command) Port: port number (1 or 2)

ŸSync data card status

3

UTY4000-007

Image 3
Contents Wegener Communications R Installation/Operation Guide Unity Synchronous Data OptionInstallation Option Card InstallIntroduction Customer Premises Wiring Control and Status IndicationsFrom Terminal From Front-panel Sync Data Card setup with local control enabledUTY4000 Sync Data Kit Installation