TROUBLESHOOTING
Problem
Unit does not turn on.
Blade does not move during operation.
The motor housing is vibrating excessively.
| Possible Cause |
| Solution |
|
|
|
| ||
| The power switch and |
| Place the switch ring |
|
|
| over the power switch. |
| |
| switch dent are not |
| Refer to “Parts |
|
| properly connected. |
| Identification” on page 3 |
|
| A foreign object is |
| for proper placement. |
|
|
| Remove the object. |
| |
| lodged in the power |
|
| |
| switch. |
|
|
|
| Movement has stopped |
| Disconnect the power |
|
| due to blockage of the |
|
| |
| blade or an overload of |
| plug. Remove blade and |
|
| food. |
| clear excess food. |
|
| A foreign object is |
| Remove the foreign |
|
| lodged between the |
|
| |
| blade carriage and the |
| object. |
|
| container. |
| Slide collection cup out |
|
| The container is |
|
| |
|
| of the container and |
| |
| overloaded with |
| remove processed food. |
|
| processed food. |
| Replace collection cup |
|
|
|
| and resume operation. |
|
| The unit is being used on |
| Use only on a level, dry |
|
| an uneven surface. |
| surface. |
|
|
|
|
|
|
NOTE:
If blades or inserts are damaged or deformed, or if performance becomes noticeably poorer, contact an Aroma customer service representative for replacement or repair.
22