Magic Chef Electric Built-In Double Cavity Wall Oven Location, Outside Wiring, House Wiring

Page 3

LOCATION

Place oven where it will be well lighted. For proper baking and cooking results, oven must be level. Use a spirit level on center oven rack to level. THIS ELECTRIC OVEN IS APPROVED FOR INSTALLATION IN COMBUSTIBLE CABINETRY. SEE INSTALLATION DIAGRAM FOR THE OVEN.

WARNING

Be sure OVEN is DISCONNECTED from POWER SUPPLY before examining any of the electrical equipment.

OUTSIDE WIRING

Your local utility company will tell you whether the present electric service to your home is adequate. It may be necessary to increase the size of the wiring to the house and service switch to take care of the electrical load demanded by the oven and/or top section. The wattage (K.W. rating) load for the oven is specified on the name plate on the unit.

HOUSE WIRING

Most local building regulations and codes require that all electrical wiring be done by licensed electricians. All wiring should conform to Local or National Electrical Codes. This oven requires a single phase three wire 120/240 or a 120/208 volt, 60 Hz. AC circuit. Wiring codes require that a separate circuit be run from the main entrance panel to the oven and that it be equipped with separate disconnect switch and fuses, either in the main entrance panel or in a separate switch and fuse box.

RANGE CONNECTIONS

The flexible armored conduit supplied with the oven must be connected to an approved electrical junction box by means of an approved conduit to box connector. THE FRAME OF THE OVEN IS GROUNDED TO NEUTRAL ONLY WHEN THE WHITE AND BARE WIRES AT THE END OF OVEN CONDUIT ARE JOINED TOGETHER. Connect the white and bare wire at the end of the oven conduit to the neutral (white) wire of the branch circuit. If used on new branch-circuit installations (1996 NEC), mobile homes, recreational vehicles, or in an area where local codes prohibit grounding through the neutral conductor, untwist or disconnect the bare wire and connect the bare wire to ground in accordance with local code. Connect the white wire to the branch circuit. The red and black wires must be connected to the remaining two conductors of the branch circuit. Connect all wires to the branch circuit with approved connectors. Use copper or aluminum wire. If aluminum wire is used, use connectors recognized for joining aluminum to copper.

APPROVED CONNECTOR

RANGE CONDUIT

BLACKRED

BARE

WHITE

APPROVED BOX

L1 APPROVED

CONNECTION

NEUTRALL2

BRANCH CIRCUIT (POWER SUPPLY)

RANGE GROUNDED THROUGH NEUTRAL CONDUCTOR

3-WIRE INSTALLATION

APPROVED CONNECTOR

RANGE CONDUIT

 

BLACK

RED

 

 

BARE

WHITE

APPROVED BOX

 

L1

APPROVED

 

CONNECTION

 

L2

NEUTRAL

BRANCH CIRCUIT

(POWER SUPPLY)

 

 

SEPARATE GROUND

WIRING METHOD IF CODE DOES NOT PERMIT GROUNDING THROUGH NEUTRAL CONDUCTOR & ALSO REQUIRED IN MOBILE

HOMES.

4-WIRE INSTALLATION

3

Image 3
Contents Installation Instructions Electric BUILT-IN Double Cavity Wall OvensImportant Save for Local Electrical INSPECTOR’S USE Electric BUILT-IN Double Cavity Wall Ovens Wide Cutout Location Outside WiringHouse Wiring Wire InstallationHornos Eléctricos Empotrados DE Pared CON Cavidad Doble DE Instrucciones DE InstalaciónFrente DEL Gabinete Cableado DE LA Casa UbicaciónAdvertencia Cableado ExteriorMise EN Service Fours Électriques Encastrés DE 24 PO À Cavité DoubleImportant Conserver Pour L’INSPECTEUR D’ÉLECTRICITÉ Local Devant DE ’ARMOIRE Connexions DE LA Cuisinière EmplacementInstallation Électrique DE LA Maison Raccordement AU Secteur