TROUBLESHOOTING CHART:
THE PROBLEM | THE CAUSE | THE SOLUTION | ||
|
|
|
|
|
Won't toast... | a. Toaster cold. | a. | Allow five (5) minutes for warm up. | |
| b. Wrong power switch position. | b. | Position power switch to full power. | |
| c. Wrong conveyor speed setting. | c. | Reduce conveyor speed. | |
Toasts unevenly... | d. Only part of product surface is | d. | Reduce conveyor speed. | |
|
| Toasted. |
|
|
| e. Product located too far to side of | e. | Place product on conveyor between | |
|
| conveyor. |
| end links. |
|
|
|
| |
Product sticks to | f. Butter or butter substitute used on | f. | Discontinue use of butter or butter | |
conveyor or slide.. |
| product. |
| substitute. |
| g. Conveyor surface has | g. | Follow daily cleaning methods to | |
|
| residue. |
| remove & prevent residue. |
| h. Very moist or doughy product. | h. | Use different source or | |
|
|
|
| product. |
| i. | Product not defrosted or thawed. | i. | Defrost/thaw product. |
No power... | j. | No power to receptacle. | j. | Check circuit breaker. |
| k. Toaster unplugged. | k. | Plug in toaster. | |
| I. Loose connections. | I. | Check connections. | |
| m. Power switch. | m. Check that switch is on & | ||
|
|
|
| operational. |
Won't heat... | n. Loose connections. | n. | Check connections. | |
| o. Faulty power switch. | o. | Replace power switch. | |
| p. Burnt out element. | p. | Replace element. | |
Lighter toast | q. Speed control setting. |
| q. Reduce speed control setting. | |
Under peak loads. | r. Very moist product. | r. | Use different source or day old | |
|
|
|
| product. |
| s. Product too cold. | s. | Allow product to warm to room | |
|
|
|
| temperature. |
| t. Toaster cavity temperature being | t. | Add 1" or more spacing between | |
|
| quenched. |
| product. |
Conveyor won't | u. No power. | u. | Check circuit breaker. | |
move... | v. Conveyor links are binding. | v. | Check conveyor for bent links. | |
| w. Drive chain too loose or too | w. | Adjust drive chain. | |
|
| tight. |
|
|
| x. Loose or bad connection | x. | Check for loose or bad | |
|
| between speed control and |
| connection. |
|
| conveyor motor. |
|
|
| y. Conveyor motor burnt out. | y. | Replace conveyor motor. | |
| z. Speed control burnt out. | z. | Replace speed control. | |
|
|
|
|
|
7