FUNCTION LIST (Continued)
Circuit Board LED Indicators -
LED # | LED Color | Illuminates: |
|
|
|
1 Bath | Red | When bath temperature is above 34 degrees F. |
|
|
|
|
| Flashes slowly when compressor is in a 6 minute delay period. |
|
|
|
|
| Open bath thermistor circuit will flash #1 and #2 LED’s 1 time every 3 |
|
| seconds. The compressor will not run under this condition. |
|
|
|
|
| Shorted bath thermistor circuit will flash #1 and #2 LED’s 2 times every 3 |
|
| seconds. The compressor will not run under this condition. |
|
|
|
2 Bath | Green | When bath temperature is below 34 degrees F. |
|
|
|
3 | Green | When the compressor should be ON. |
|
|
|
4 Cabinet | Red | When the cabinet temperature is above 50 degrees F. |
|
|
|
|
| Flashes slowly when cabinet temperature exceeds 50 degrees F for 4 |
|
| hours. Dispense functions are locked out under this condition. Power |
|
| down the dispenser to reset. |
|
|
|
|
| Flashes rapidly if dispense is attempted in lockout condition. |
|
|
|
|
| Open cabinet thermistor circuit will flash #4 and #5 LED’s 1 time every 3 |
|
| seconds. |
|
|
|
|
| Shorted cabinet thermistor will turn #4 and #5 LED’s on steady. |
|
|
|
5 Cabinet | Green | When cabinet temperature is below 50 degrees F. |
|
|
|
4 |
| 1 |
5 |
| 2 |
|
| 3 |
| FIG 19 | P3845 |
|
|
18 | 44744 032811 |
|