Bunn VP17 manual Service, Component Access

Page 3

SERVICE

This manual provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem.

WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified service personnel. The brewer should be unplugged when servicing, except when electrical tests are re- quired and the test procedure specifically states to plug in the brewer.

COMPONENT ACCESS

WARNING - Disconnect the brewer from the power source before the removal of any panel or the replace- ment of any component.

All components are accessible by the removal of the top cover and front inspection panel and warmer assemblies.

The top cover is attached with one #4-40 screw.

The front inspection panel is attached with four #6-32 screws.

The warmer assembly is attached with three #4-40 screws.

 

Contents

Control Thermostat

............................................... 4

Limit Thermostat

5

ON/OFF Switch

6

Tank Heater

7

Tank Heater Switch

8

Warmer Elements

10

Wiring Diagrams

11

FIG. 1 COMPONENT ACCESS

P1160.40

 

Page 3

46721

052512

 

Image 3
Contents VP17 BUNN-O-MATIC Commercial Product Warranty Component Access ServiceGently remove the capillary bulb and grommet from the tank Control ThermostatLimit Thermostat Limit ThermostatConnect wire to Terminal #1 as follows ON/OFF Warmer SwitchTank Heater Tank HeaterService Tank Heater Switch VP17B and early model VP17 Service Tank Heater Switch Warmer Element Terminals P1167 Warmer ElementsVolts AC VP17-1/-2/-3VP17-1/-2/-3 VP17B-1/-2/-3 Volts AC 46721 052512 46721 052512
Related manuals
Manual 19 pages 4.79 Kb