Bunn H5X, H5E, DV service manual Service Solenoid Valve Early Models

Page 15

SERVICE (cont.)

Solenoid Valve (Early Models)

Location:

The solenoid valve is located behind the large access panel on the left side of the dispenser.

To test the solenoid valve, access will also be needed to the electronic control board.

BUNN

H 10

P1994

FIG. 15a SOLENOID VALVE

Test Procedure:

1.Disconnect the dispenser from the power source and turn off the water supply to the dispenser.

2.Remove the pink wire from terminal 5 of the elec- tronic control board.

3.Check the voltage across the solenoid valve coil terminals with a voltmeter. Connect the dispenser to the power source. The indication must be 200 to 240 volts ac for 200 to 240 volt models after a delay of approximately 5 seconds.

4.Disconnect the dispenser from the power source.

If voltage was present as described, proceed to #5. If voltage was not present as described, refer to the Wir- ing Diagrams and check the dispenser wiring harness.

5.Remove both wires from the solenoid valve coil terminals.

6.Check for continuity across the solenoid valve coil terminals.

If continuity is present as described, reconnect the wires and proceed to #7.

If continuity is not present as described, replace the solenoid valve coil.

7.Check the solenoid valve for coil action. Connect the dispenser to the power source. Listen carefully in the vicinity of the solenoid valve for a “clicking” sound after approximately 5 seconds, as the coil magnet attracts the plunger.

8.Disconnect the dispenser from the power source.

9.Reconnect the pink wire to terminal 5 of the elec- tronic control board.

If the sound was heard as described and water will not pass through the solenoid valve, there may be a blockage in the water line before or after the solenoid valve or the solenoid valve may require inspection for wear and removal of waterborne particles.

If the sound was not heard as described, replace the solenoid valve.

Removal and Replacement:

1.Remove all wires from the solenoid valve coil.

2.Turn off the water supply to the dispenser.

3.Disconnect the water lines to and from the solenoid valve.

4.Remove the two 8-32 slotted-head screws holding the solenoid valve and mounting bracket to the component bracket.

5.Lift out the solenoid valve.

6.Remove the two 10-32 slotted-head screws holding the solenoid valve to its mounting bracket.

7.Securely install the new solenoid valve to its mount- ing bracket. The direction of flow arrow must be pointing towards the tank lid.

8.Attach the solenoid valve and mounting bracket to the component bracket.

9.Securely fasten the water lines to and from the solenoid valve.

10.Reconnect the wires, FIG. 8.

WHI/BLU to Contol

Board T1

RED to Terminal Block

RED to Control Board T4

P1779

FIG. 15b SOLENOID VALVE WIRING

15

42311 071310

 

Image 15
Contents Phone 217 529-6601 FAX 217 H10X/H5X H5E/DV PC H5 ElementBUNN-O-MATIC Commercial Product Warranty Contents Remedy Fault CodesProblem Flashes Description of FailureProblem Probable Cause Remedy Deposits. Delime as required Water boils continuously Temperature controlNoises Water supply Ready indicator will not light Lime build-upComponent Access H10X Component Access H5E/DV-PC/XLocation ServiceLiquid Level Control Flow Charts Electronic ControlsService Electronic Controls Liquid Level Control Test ProcedureService H5X Thermostat Replace the electronic control board Location Limit thermostat is located on the tank lid Service Limit ThermostatSafety Overflow Wiring Service Safety Overflow SwitchIf voltage was present as described, proceed to #5 Service Solenoid Valve Late ModelsService Solenoid Valve Early Models Service Tank Heater Location Tank heater is located in the tank lidCheck for continuity across the tank heater termi- nals Thermistor Position Service Steam Sensor ThermistorLocation Dispense Valve is located behind control panel Service Dispense Valve PC OnlyTest Procedures Removal and ReplacementSingle Phase Early H5E, H5X, H10X Install jumper thru ver120V AC 2 Wire + GND 120/208V AC 3 Wire + GND 120/240V AC 3 Wire + GNDSchematic Wiring Diagram H5E-PC 230V AC 2 Wire + GNDH5-PC Schematic Wiring DiagramWire + GND Schematic Wiring Diagram H5E/H5X Relay Schematic Wiring Diagram H5XA, H5EA CESingle Phase Schematic Wiring Diagram H5 Element
Related manuals
Manual 24 pages 29.7 Kb Manual 9 pages 10.17 Kb Manual 2 pages 44.15 Kb Manual 25 pages 6.43 Kb

DV, H5E, H5X specifications

The Bunn H5E and H5X coffee machines represent a leap forward in brewing technology, specifically tailored for commercial use. Both models focus on delivering high-quality coffee while maximizing efficiency, making them ideal choices for busy cafés and restaurants.

The Bunn H5E features a unique 5-liter dual tank system, which allows for faster brewing times and reduces wait periods for customers. This dual tank setup facilitates the simultaneous preparation of multiple coffee types, catering to a diverse clientele. The H5X, on the other hand, is equipped with advanced electronic controls that permit precise temperature adjustments to ensure that the ideal brewing conditions are maintained, enhancing flavor extraction.

One of the standout features of both models is the patented BrewOptimized Technology. This technology helps maintain optimal water temperature and consistent flow rates throughout the brewing process, ensuring that each cup of coffee meets the high standards expected in commercial settings. Additionally, the units utilize a patented stainless steel brew basket that enhances durability and simplifies cleaning, making maintenance less of a chore for busy staff.

Another significant characteristic of the H5E and H5X is their programmable settings, which allow operators to customize brewing parameters according to their specific preferences or customer needs. This flexibility means that establishments can experiment with various coffee profiles, ensuring that they serve only the best products to their patrons.

Safety is also a priority in the design of these machines. The H5E and H5X come equipped with built-in safety features such as automatic shut-off and thermal overload protection, which help to prevent accidents and enhance longevity. Moreover, their compact design allows for easy installation in a variety of settings, whether it's a small coffee stand or a large restaurant operation.

Both the Bunn H5E and H5X models are energy-efficient, with features that minimize power consumption without compromising performance. This focus on sustainability not only helps reduce overhead costs but also appeals to environmentally conscious consumers.

In summary, the Bunn H5E and H5X coffee machines are engineered for high performance, reliability, and versatility. With features designed to provide quick, quality coffee while ensuring ease of operation and maintenance, these machines are ideal for any establishment that takes its coffee seriously. Whether you’re brewing for a crowd or crafting specialty drinks, the H5E and H5X stand ready to deliver excellent results every time.