6.3Floor Temperature Limits (AF mode only)
NOTE: To avoid damaging your floor, follow your floor supplier’s recom- mendations regarding floor temperature limits.
The minimum and maximum floor temperature limits are 5 °C (41 °F) and
28 °C (82 °F) by default. To modify these limits, proceed as follows:
nSwitch the thermostat to Standby.
o Press and hold the button. p Switch the thermostat back to On.
qRelease the button when the minimum temperature limit (FL:LO) appears.
r Set the minimum temperature limit using the buttons.
s Press the button to display the maximum temperature limit (FL:HI).
tSet the maximum temperature limit using the buttons. u Press Mode/Ret to exit.
tModes of Operation
The thermostat has 3 modes of operation.
7.1 Automatic Mode
The thermostat follows the programmed schedule. To place the ther- mostat in this mode, press Mode/Ret until is displayed. The data of the current schedule period are also displayed.
Temporary Bypass
If you modify the setpoint temperature (by pressing the , or button) when the thermostat is in automatic mode, the new tempera- ture will be used until the beginning of the next period. flashes dur- ing the bypass. You can cancel the bypass by pressing Mode/Ret.
Programmed Schedule
The schedule consists of 4 periods per day which represents a typi- cal week day. You can program the thermostat to skip the periods that do not apply to your situation. For example, you can skip periods 2 and 3 for the weekend.
Period | Description | Associated temperature setting |
Wake-up
Away from home
Return home
Sleep
The Comfort ( ) temperature is used in periods 1 and 3 and the
Economy ( ) temperature is used in periods 2 and 4. For example, when the period changes from 1 to 2, the setpoint automatically changes from Comfort ( ) temperature to Economy () temperature.
You can have a different program for each day of the week; i.e., each period can start at different time for each day of the week. The thermostat has been programmed with the following schedule.
Period Setting | MO | TU | WE | TH | FR | SA | SU |
| 6:00 | 6:00 | 6:00 | 6:00 | 6:00 | 6:00 | 6:00 |
| 8:30 | 8:30 | 8:30 | 8:30 | 8:30 | --:-- | --:-- |
| 17:00 17:00 17:00 17:00 17:00 | --:-- | --:-- |
| 23:00 | 23:00 | 23:00 | 23:00 | 23:00 | 23:00 | 23:00 |
To modify the schedule:
nPress Pgm to access the programming mode. Period 1 is selected.
oPress Day to select the day to program (hold for 3 seconds to select the entire week).
pPress Hour and Min to set the start time of the selected period, or press Clear if you want to skip the period (--:-- is displayed). NOTE: If you intend to use only 2 periods, set periods “1 and 4” or periods “2 and 3”. Early Start will not work if you set periods “1 and 2” or periods “3 and 4” .
qPress Pgm to select another period, or press Day to select another day. Then repeat step 3.
rPress Mode/Ret to exit the programming mode.
NOTE: If no button is pressed for 60 seconds, the thermostat will automatically exit the programming mode.
7.2 Manual Mode
The programmed schedule is not used. The temperature must be set manually. To place the thermostat in this mode:
nPress Mode/Ret until is displayed.
oSet the temperature using the , or button.
7.3 Vacation Mode
In this mode, the thermostat is set to Vacation temperature. There are two ways to place the thermostat in Vacation mode:
By pressing the button on the thermostat. When the Vacation
mode is activated using the button, the icon appears on the screen without flashing.
From an Aube telephone controller (CT240/CT241) or any other remote control device equipped with a dry contact if your power base is equipped with the ECONO input. When the contact
closes, the Vacation mode is activated and the icon flashes on the screen. All buttons on the thermostat are locked. When the contact opens, the thermostat returns to the preceding mode.
NOTE: When the Vacation mode is activated using a remote control device, it can only be deactivated using the device.
uError Messages
The measured temperature is below the thermostat’s display range. Heating is activated.
The measured temperature is above the thermostat’s display range. Heating is deactivated.
Verify the thermostat and sensor connections.
:
vTechnical Specifications
Power supply: Refer to the power base’s installation guide.
Display range: 0 °C to 70 °C (32 °F to 158 °F)
Ambient setpoint range (A/AF modes): 5 °C to 30 °C (40 °F - 86 °F)
Floor setpoint range (F mode): 5 °C to 40 °C (40 °F - 104 °F)
Floor limit range (AF mode): 5 °C to 40 °C (40 °F - 104 °F)
Display resolution: 0.5 °C (1 °F)
Operating temperature: 0 °C to 50 °C (32 °F to 120 °F)
Storage temperature: -20 °C to 50 °C (-4 °F to 120 °F)
Heating cycle length: Refer to the power base’s installation guide
Data backup: In the event of a power failure, most settings are saved. Only the time must be re-adjusted if the power failure lasts more than 6 hours. The thermostat will return to the mode that was active prior to the power failure.
;Warranty
Aube warrants this product, excluding battery, to be free from defects in the work- manship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube's option).
If the product is defective,
(i)return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or
(ii)contact Aube. Aube will make the determination whether the product should be returned, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or malfunction was caused by dam- age which occurred while the product was in the possession of a consumer.
Aube's sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR- RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PROD- UCT. Some provinces, states or regions do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some provinces, states or regions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from province, state or region to another.
Customer Assistance
For any questions regarding product installation or operation, contact us at:
705 Montrichard Saint-Jean-sur-Richelieu, Quebec J2X 5K8
Canada
Tel.: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
E-mail: aube.service@honeywell.com
For more information on our products, visit us at: