Cabletron Systems FRX6000 Sdlc Link Stn rcvd FRMR, Inv. cmd 704, Sdlc Rem Stn sent invalid Nr 710

Page 76

Configuring the Trap Table

SDLC Rem. Link Stn Not Responding

701

Self-explanatory. (Rem Link Stn is the Remote Link Station.)

 

Severity

Major (Level 2)

 

Action

Check the PU to make sure it is operational.

 

SDLC Link Stn Sent DM

702

The link station sent a Disconnect Mode response, and the logical link is down.

Severity

Major (Level 2)

 

SDLC Link Stn rcvd FRMR, Inv. cmd

704

The remote device received an invalid command and responded with a Frame Reject.

Severity

Major (Level 2)

 

SDLC Stn rcvd FRMR, IFLD invalid

705

The remote device received an unpermitted I frame and responded with a Frame Reject.

Severity

Major (Level 2)

 

SDLC Stn rcvd FRMR, Nr invalid

706

The remote device received a frame with an invalid N(r) and responded with a Frame Reject.

Severity

Major (Level 2)

 

SDLC Stn rcvd FRMR, Ifld too long

707

The remote device received an I frame that was too long and responded with a Frame Reject.

Severity

Major (Level 2)

 

SDLC Rem Stn sent Invalid Command

708

The remote device received an invalid or unsupported command.

 

Severity

Major (Level 2)

 

SDLC Rem Stn sent unexpected IFLD

709

The remote device send an unpermitted I frame.

 

Severity

Major (Level 2)

 

SDLC Rem Stn sent invalid Nr

710

The remote device sent a frame with an invalid N(r).

 

Severity

Major (Level 2)

 

3-26

Trap Messages

Image 76
Contents Page Page Virus Disclaimer Restricted Rights Notice Contents Chapter Chapter Configuring the Trap TableChapter Status and Configuration Chapter BSC Interactive Configuration Chapter SNA Status and ConfigurationChapter IP Interface Configuration Chapter SmartSwitch Voice Configuration Appendix a FRX4000, FRX6000, and SmartSwitch MIB ComponentsIPX Interface Configuration Chapter Bridge ConfigurationChapter Using this Guide Using this Guide Conventions What’s not in the FRX User’s GuideScreen Displays Using the Mouse ButtonGetting Help FRX4000, FRX6000, and SmartSwitch 1800 Firmware Year 2000 ComplianceUsing the FRX4000, FRX6000, and SmartSwitch 1800 Hub View Using the Hub ViewUsing the FRX4000, FRX6000, and SmartSwitch 1800 Hub View Navigating Through the Hub ViewFRX4000, FRX6000 and the SmartSwitch 1800 Hub Views Port and Module Color Codes Module and Port Color CodesDown Using the Mouse in a Hub View Module Mousing Around a Module DisplayHub View Front Panel UptimeName LocationIP Address Clicking the Device button displays the Device menu, Figure Monitoring Hub Performance Device, Module, and Port Menus Selecting a Port Display Form Operation StatusPort Type Admin StatusPort State Yet Connector Type SpeedMax Packet Size If IndexViewing Device Information Configuring RLP ProtocolsPresent in the hub Change or add protocols for the selected RLP Configuring Serial Port Protocols Viewing Serial Port Information Serial Port Information WindowSerial Port Pin Status Using the FRX4000, FRX6000, and SmartSwitch 1800 Hub View Viewing LAN Port Information Viewing Statistics RLP HealthLittle differently in general, however, frames are rejected Serial Port Health LAN Card Health Transmitted by the selected LAN interface, expressed as a Viewing Statistics Thresholds RLP Statistics ThresholdsSerial Port Statistics Thresholds Using the FRX4000, FRX6000, and SmartSwitch 1800 Hub View Setting the Polling Intervals Managing the HubContact Status Device General StatusDevice Configuration Port Operational StateEnabling and Disabling Serial Ports Applying Port-level ChangesAbout Traps Launching the Trap TableStatus SeverityConfiguring Traps Transmitter Stuck 146 Trap MessagesConfigured for normal sequence numbering Illegal TC/Gen Clk Combination 219 Excessively noisy line 250LP Buf Usage exceeded T n C n 304 LP Msg Queued exceeded T n C n 305LP Rej Frm/Sec exceeded T n C n 308 Rcv Frm/Sec exceeded T n C n 311Tran Frm/Sec exceeded T n C n 312 RTrn Frm/Sec exceeded T n C n 313FCS Rej/Sec exceeded T n C n 314 Log Rej/Sec exceeded T n C n 315Trn Err Ratio exceeded T n C n 316 Rcv Err Ratio exceeded T n C n 317Receive Yellow Alarm Condition Set 338 Receive Yellow Alarm Condition Set 339LIC n Installed, Not Configured 377 LIC n Configured, Not Installed 378Link Disabled 401 Link Disconnected 402Link Up 403 Link Failed 404PVC Reset 410 Received Reset LCN = n, cc = n dc = n 411Received Reset Confirm 412 Call Clr LCN = n cc = n dc = n 407End of Congestion, n events lost 415 PAD Autocall Retries Exhausted 416Frame Relay Link Failed 417 PU Status p = n stn = 0xn status = n 426File Update FRDLCI.DAT 429 Received Port Disable Request 430Node Under Remote Control 432 Remote Control Released 433DOS Error Handler Exceeded Limit 438 Database Error, Access Restricted 439Async Init File Upd ASYSETUP.DAT 441 RCV Unknown Event Code from Net 436Default File Upd X25REC.DAT 452 Alarm Enable File Upd ERRMSG.TXT 453Remote Update File Upd UPDATE.TXT 454 Port Config File Upd PRTPAR.DAT 445PAD Login File Upd PADLOG.DAT 458 CUG File Updated CUGPAR.DAT 461IP Route File Upd IPRSUB.DAT 459 IP Interface File Upd IPRSUB.DAT 460LP Msg Queued Under Threshold 465 LP Rcv Frm/Sec Under Threshold 466LP Trn Frm/Sec Under Threshold 467 LP Rej Frm/Sec Under Threshold 468Error adding interface n 483 Error modifying interface n 484Rcv Err Ratio Under Threshold 477 Port Rcv Usage Under Threshold 478Error adding route with destination n, mask n, router n 490 491BAG n capped at n but trunk Maxdps n 492 IPX Route File Upd IPXRSUB.DAT 493Alloc Error on Master Snmp Agent 494 Bpad Invalid Q Pkt n-PL 500Bpad Invalid Pkt n-PL 501 Bpad Invalid MSG n-Link 502Bsci Invalid port number or type 515 Bsci Invalid message transfer 516Bsci Invalid circuit operations 517 Bsci Invalid state event action 518Enter Service Affecting Condition 532 Dlci n No Response to Status ENQ 536 Dlci n Flow Control On 537Dlci n Frame Discarded-Flow Ctl 538 Dlci n Line does not exist 539Dlci n frame relay PVC deleted 545 Dlci n frame relay PVC connected 546Dlci n Data Received on Inactive PVC 547 Dlci n No Status ENQ Received 548Fr RLP/PORT/DLCI Mismatch 644 Receive Remote Alarm condition Set 652 Receive Remote Alarm condition Cleared 655Receive Loss of Sync condition Cleared 653 Receive Carrier Loss condition Cleared 654Sdlc Rem Stn sent Invalid Command 708 Sdlc Link Stn rcvd FRMR, Inv. cmd 704Sdlc Stn rcvd FRMR, Ifld invalid 705 Sdlc Stn rcvd FRMR, Nr invalid 706Sdlc Station Inactivity time exp 712 Sdlc XID Retries exhausted 713Sdlc Rem Tx Frame exceeds Maxdata 717 Sdlc Rem sent UA in NRM 718LLC/2 Sabme Received when open 738 LLC/2 Frmr Rcvd, Invalid Command 739LLC/2 Frmr Rcvd, Ifld not permitted 740 LLC/2 Frmr Rcvd, Invalid Nr 741LLC/2 Frmr Rcvd, Invalid Command 743 Excessive Link CRC errors 759Sdlc Transmit link error 761 LLC/2 Frmr Sent, Ifld not permitted 744Sdlc Link Stn rcv FRMR, Unexp. Ifld 762 Configuring the Subscriber Table About Subscriber IDsAccessing the Subscriber Table Subscriber Table WindowConfiguring the Subscriber Table Subscriber IDAlgorithm Systematic RedirectRedirect Busy Redirect Out-of-OrderConfiguring Routing Table Entries PriorityPath PortAdding or Modifying Subscriber Table Entries Configuring Address Table EntriesIndex AddressRouting Table Deleting Table Entries Address TableFrame Relay Status Configuration Configuring Frame Relay Ports Port ConfigurationMax Bytes per Frame Line SpeedN2 Error Threshold N1 Polling CountT1 Link Integrity Timer T2 Polling Verification TimerN3 Monitored Events Count Maximum Supported VCsBlocked Flag Logical DCEGenerate Clock Receive Clock from DTEOutgoing Rate Control Backup Use OnlyBandwidth Allocation Changing Configuration Values Dlci Rate ConfigurationApplying Port-level Changes Dlci CIR In/OutBC In/Out Be In/OutBackup Group Number Backup ProtocolState Changing Dlci Rate ValuesFrame Relay Backup Groups Configuring Frame Relay Backup Groups Wait Timer Protocol EnabledChanging Backup Group Values GroupConfiguring Logical Ports Logical Port Dlci NumberDefault Packet Size Bandwidth Allocation GroupSetup Packet Window Size Default Throughput ClassMax UnACK Packets/Channel Closed User Group MemberMake Calls Outside CUG Encapsulation MethodFlow Control Negotiation Throughput Class NegotiationViewing Frame Relay Status Changing Configuration ValuesLMI Transmitted and Received Management StatsAnxd Transmitted and Received Congestion Stats DE Transmitted and ReceivedErrors Becn Transmitted and ReceivedFecn Transmitted and Received Frames DiscardedPage Status and Configuration Configuring X.25 Physical Ports X.25 Physical Port ConÞgurationInactivity Timer Disconnect TimerSetup Timer Closed User Group Index Dial In/Out Network Trunk GroupFlow Control Negotiation Viewing X.25 Status Sabm Transmitted/Received UA Transmitted/ReceivedDisc Transmitted/Received DM Transmitted/ReceivedInfo Transmitted/Received RNR Transmitted/ReceivedFrmr Transmitted/Received Rej Transmitted/ReceivedStatus and Configuration Viewing X.25 Status SNA Status and Configuration Configuring SNA Ports Sdlc Port ConfigurationPacket Size MAX Retries Lpda Support PAD TypeNRZ Data Encoding Idle Fill Char Disable Rqst DisconnectL1 Duplex Sdlc PU Configuration Local Subscriber Id Auto Call Enabled L2 Data ModeRemote Subscriber Id Lpda Resource IdSdlc PU LLC2 Configuration Changing Sdlc PU Subscriber ValuesLocal SAP Address Local MAC AddressTi-Inactivity Timer T1-LLC2 Reply TimerT2-Rcv Ack Timer N2-Max LPDUsN3-Max Info LPDUs Tw-Max Out LPDUsSuppress XID Changing Sdlc PU LLC2 ValuesSdlc Link Station Configuration Sdlc Link Station ConÞguration windowReply Timeout Max RX PDU SizeMax TX PDU Size Max Rx UnACK I-FramesData Mode Retry Sequence Repeat CountRNR Limit Group Poll AddressConfiguring LLC2 Changing Sdlc Link Station ValuesTraffic Group Host IndexSession Type Host MAC AddressT1-Reply Timer T2-Recv Ack TimerTw-LPDUs Outstanding N3-LPDU CountN2-Expired T1 LPDUs Source MAC Address Mask Routing Subscriber IDInterface Number Configuring LLC2 Host Connections Originated Connections TableSequence TypeSdlc Port Statistics Viewing Sdlc StatusChanging Host Connections Dwarf Frames Received Invalid LS AddrFrames Received and Transmitted Protocol Errors Inactivity TimeoutsLocal Re-Tx I-Frames Remote Re-Tx I-FramesSdlc Link Station General Statistics Inactivity TOsSdlc Link Station Rx and Tx Statistics Retries ExpPoll Poll ResponseFrame UI-FramesOctets RetransmitsBSC Interactive Configuration Configuring Bsci PortsMax Frame Size No Response Timer Retransmission PeriodMax Retransmissions Start Sync CharsError Retransmit Count NAK Retry CountMultidrop Slow Poll Retry CountEnd-to-End ACK Full DuplexChanging Bsci Port Configuration Values Clear VC on Last Dev DownPad Packet Assembler/Disassembler Type Answer Non ConfiguredBsci Subscriber ID Information Bsci Subscriber InformationConnection ID Retry TimerAuto Call Configuring Bsci Devices Adding or Modifying Bsci Subscriber InformationDevice Unit ID Control Unit IDSingle User VC virtual circuit Transparent Text Support Adding or Modifying Bsci Device InformationPrinter Attached BSC Interactive Configuration Configuring Bsci Devices Configuring IP Node Defaults IP Interface ConfigurationConfiguring IP Interfaces IP Interface ConfigurationInterface Number IP Interface Type Maximum Transmission UnitNetwork Mask Route Metric HopsRIP Full Updates RIP Delta UpdatesIcmp Add Routes Source Address Destination AddressBroadcast Address LAN CardSVC Retry Timer SVC Idle TimerMax VC PVC ConnectionProxy ARP Inverse ARPUnnumbered Interface Configuring IP Interface Secondary Addresses IP Interface Secondary Address ConÞgurationSequence Number Adding or Modifying IP Interfaces Interfaces,Adding or Modifying Secondary Addresses Configuring IPX Node Defaults IPX Interface ConfigurationConfiguring IPX Interfaces IPX Interface ConfigurationConfiguring IPX Interfaces 10-3 Network Address Interface TypeFrame Type Configuring IPX Interfaces 10-5 Diagnostics Enabled Serialization EnabledWAN Enabled NetBIOS EnabledPeriodic RIP Enabled RIP EnabledWatchdog Spoofing Transport TimeNetBIOS Hops Periodic SAP TimerSAP Age Timer Periodic RIP TimerAdding or Modifying IPX Interfaces RIP Max SizeConfiguring IPX Static Routes IPX Static SAP ConfigurationAdding or Modifying Static SAP Routes IPX Static Route Configuration Network Number Circuit IndexRouter Address Adding or Modifying IPX Static Routes Bridge Configuration Configuring Device-Level Bridging ParametersForwarding Table Size Virtual LAN IDSource Route Bridge ID Bridge Enabled IP EnabledIPX Enabled Ethernet Frame TypeConfiguring Bridge Ports Configuring Frame Relay Bridge PortsConfiguring Bridge Ports 11-5 Format LAN IDConfiguring LAN Bridge Ports Adding or Modifying Frame Relay Bridge PortsLAN Card Number LAN Type Adding or Modifying LAN Bridge Ports11-10 Configuring Bridge Ports SmartSwitch Voice Configuration Voice Node Number Configuring System-Level Voice ParametersCountry Code Country Code Extended Dial Digits Dial DigitsRing Voltage/Frequency Speed Dial Configuration Changing Parameter ValuesMinimum Voice Rate Maximum Voice RateSpeed Dial Digits Long Dial MapAdding or Modifying Speed Dial Numbers Extended Dial StringConfiguring Voice Ports DtmfCall Timer TE TimerDial Timer SLT Timeout Sample DelayJitter LevelForward Delay Make RatioBreak Ratio Dtmf On DurationAuto Dial Number Auto Poll TimerAuto Poll Hunt Group Telephony TypeSuppression Ext. Digits Source Forwarded TypeForwarded Digits Tone TypeChanging Port Configuration Values Configuring Voice InterfacesFax Supported Peer Node Type Adding or Modifying Voice Interfaces Viewing Voice Statistics Call Timeouts Calls Received and TransmittedCall Accepts Received and Transmitted Clears Received and TransmittedSmartSwitch 1800 Voice Configuration 12-20 FRX4000, FRX6000, and SmartSwitch 1800 MIB Components Ietf MIB SupportCSI Netlink MIB Support Index Index-2 Index-3 Index-4 Index-5 Index-6
Related manuals
Manual 448 pages 52.72 Kb Manual 9 pages 31 Kb

1800, FRX4000, FRX6000 specifications

Cabletron Systems, a leading player in network management and telecommunications solutions during the late 20th century, introduced several innovative products that played a crucial role in shaping enterprise networking. Among these were the Cabletron FRX6000, FRX4000, and the FRX1800, which delivered advanced features aimed at enhancing network performance, security, and scalability.

The Cabletron FRX6000 was designed as a robust multi-layer switch, ideal for large-scale enterprise environments. It supported extensive routing capabilities, allowing organizations to manage traffic efficiently even under heavy loads. The FRX6000 boasted high throughput rates and low latency, making it suitable for demanding applications. With support for various network protocols, including IP, IPX, and AppleTalk, its adaptability made it a versatile choice for diverse networking needs. Moreover, security features like VLAN support and Access Control Lists (ACLs) provided enhanced protection against potential threats.

Moving to the FRX4000, this model offered a balance between performance and cost-effectiveness. The FRX4000 maintained many of the essential features of its larger counterpart while catering to medium-sized enterprises. It provided Layer 3 routing and could handle multiple simultaneous connections, ensuring seamless communication across departments. The modular design allowed for easy upgrades, enabling businesses to expand their network infrastructure without significant overhauls. This made the FRX4000 an attractive option for organizations looking to optimize their network investments.

Lastly, the FRX1800, designed for small to medium businesses, focused on simplicity and ease of use while still incorporating powerful network management capabilities. Its user-friendly interface made it accessible for organizations lacking extensive IT resources. The FRX1800 provided essential functionalities such as Integrated Layer 2 switching and routing, network monitoring, and basic security features, ensuring that even smaller companies could maintain efficient, reliable networking without overwhelming complexity.

All three models utilized advanced technologies, including a high bandwidth backbone and state-of-the-art switching architecture, to enable fast and reliable data transfer. They also supported Quality of Service (QoS) mechanisms, allowing businesses to prioritize critical applications and ensure consistent performance across the network.

In summary, the Cabletron FRX6000, FRX4000, and FRX1800 were pivotal in enhancing network capabilities, providing organizations with scalable, secure, and high-performance options tailored to their specific needs.