CDA HCG501, HCG521 Care and Maintenance, If your Hob is not working, Contact CDA Customer Care

Page 5

Care and Maintenance

As the hob has a stainless steel or enamel surface, you should use a nonabrasive cleaner. Any abrasive cleaner (including Cif) will scratch the surface and could erase the control panel markings. Stainless steel can be effectively cleaned by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth.

Over time with use, the stainless steel surface may discolour; this is normal and does not constitute a fault with this ap- pliance. Proprietary stainless steel cleaners are available. We recommend the CDA E-Cloth available from the CDA Sales Team for cleaning stainless steel surfaces.

The enamelled parts of hobs are not suitable for cleaning in dishwashers; these should be washed by hand.

IMPORTANT:

Steam cleaners must not be used when cleaning this appliance.

Ensure that all parts are correctly replaced after cleaning before attempting to use the hob.

After removing the pan stands, ensure the rubber pads are in place on the base of the pan stand before repositioning the pan stands straight and level on the hob.

What to do if you smell gas:

1. Open doors and windows

2. Turn the gas supply off

3. Call Transco on : 0800 111 999

Burner Size

Nominal Rating

Simmer Rating

LPG Flow Rate (lh-1)

 

(kW)

(kW)

G30

G31

 

 

 

Auxiliary

1.0

0.45

73

71

 

 

 

 

 

Semi-Rapid

1.75

0.6

127

125

 

 

 

 

 

Rapid

3.0

0.9

218

214

 

 

 

 

 

Total rated gas input : 7.5kW

Mains electrical voltage: 230 – 240Vac

Total rated electrical consumption: <1W

If your Hob is not working

1.Check that the mains supply has not been switched off.

2.Check that the fuse in the spur has not blown.

3.Ensure that the burner components are not excessively soiled as this can lead to ignition problems.

Contact CDA Customer Care

A : Customer Care Department, The CDA Group Ltd, Harby Road, Langar, Nottinghamshire, NG13 9HY

T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www.cda.eu

Image 5
Contents Customer Care Department HCG501L / HCG501 / HCG521 gas hobsPlease note Appliance informationCE Declarations of Conformity Control panel Using your hobGas burners Efficient use of your Hob Igniting the BurnersTo ignite the burners, follow these instructions Burner Size Minimum Pan Diameter cm Maximum Pan Diameter cmContact CDA Customer Care Care and MaintenanceIf your Hob is not working Green & Yellow = Earth, Blue = Neutral, Brown = Live Mains Electricity ConnectionVentilation Room Volume m Air Vent Required cmGas Supply Requirements Setting up minimum flow rates Instructions to fit replacement injectors RequiredNatural Gas to LPG Conversion LPG to Natural Gas ConversionUnpacking the hob Fitting the HobFitting position of the hob If fitting a cooker hood above the hobHow to install the hob Page Customer Care Department