Extron electronic SI 26X specifications Frame Construction Ceiling Installation, General

Page 1

SI 26X

User’s Guide

Ceiling Speaker

 

 

 

 

 

Frame Construction Ceiling Installation

1

Take the cutout template from the packaging box and punch out the larger perforated circle. Place the cutout template against the ceiling and trace the inside of the circle. Carefully cut out the ceiling material around the circle.

Trace template.

Cut Material

 

2

Remove the grill from the speaker.

3

Bring the speaker cable through the hole in the ceiling and connect the leads to the speaker’s spring terminal clips.

6

Install the speaker grill.

Apply 4 pieces (supplied) of black putty to the edge of the grill.

Packaging

Cutout Template

User’s Guide

4

Red (+) Black (-)

Specifications:

Insert the speaker through the bottom of the hole in the ceiling.

5

Loosen the four screws on the front baffle (counterclockwise) ½ turn. Then tighten the screws (clockwise) until the dog legs clamp the speaker to the ceiling.

CAUTION Do not over tighten screws.

Acoustic & Electrical

Speaker type

2-way, open back ceiling speaker

Frequency range

50 Hz to 20 kHz, -10 dB, half space

Power capacity

50 W continuous program,

 

 

25 W continuous pink noise

Nominal sensitivity

89 dB, 1 W, 1 m, half space

Nominal impedance

8 ohms

Crossover frequency

3 kHz

Nominal coverage

110°

Woofer

6.5" (165 mm) polypropylene cone

 

 

with moisture resistant coating

Tweeter

0.75" (19 mm) titanium dome

 

 

 

General

 

Temperature/humidity

Storage: -40 to +158 °F (-40 to +70 °C) /

 

 

10% to 90%, noncondensing

 

 

Operating: +32 to +122 °F (0 to +50 °C) /

 

 

10% to 90%, noncondensing

Warranty

5 years parts and labor

NOTE All nominal levels are at ±10%.

NOTE Specifications are subject to change without notice.

68-1166-01 Rev. B

04 06

Image 1
Contents Acoustic & Electrical Frame Construction Ceiling InstallationGeneral Ceiling Speaker Suspended Ceiling Installation