Extron electronic setup guide MPA 152 MD Setup Guide, Rev a, 68-1989-50

Page 1

MPA 152 MD • Setup Guide

THE MPA 152 MD IS AN ACCESSORY TO A MEDICAL SYSTEM.

The Extron® MPA 152 MD mini power amplifier delivers up to 15 watts (rms) per channel (stereo or dual mono) into a 4 ohm sound system or 8 watts (rms) per channel into an 8 ohm system.

For complete instructions, see the MPA 152 MD User Guide, which is available on the Extron website (www.extron.com).

To install and set up an MPA 152 MD, follow these steps:

1.Turn all of the equipment off and disconnect it from power sources.

2.Attach the four rubber feet (provided) and place the MPA 152 MD in a suitable location.

3.Attach the speakers to the MPA 152 MD (see the figure at right).

4.Attach inputs to the MPA 152 MD unit from the audio source, the projector, or both. There are three audio inputs (shown in the figure at right), which can be used individually or together:

OUTPUT

 

4/8

 

OHMS

L

R

 

Tip (L)

Tip (+)

Ring (R)

Sleeve ( )

Sleeve ( )

RCA Connector

3.5 mm TRS Connector

One pair RCA connectors (unbalanced)

One 3.5 mm stereo tip-ring-sleeve connector (unbalanced)

One 3.5 mm, 5-pole captive screw (balanced/unbalanced)

Tip

 

Tip

Ring

L

Sleeve

 

Sleeves

 

Tip

Tip

R

Ring

Sleeve

 

Balanced audio

 

Unbalanced audio

L R

NOTE: The MPA 152 MD amplifier mixes all right channel

inputs to a single signal and all left channel inputs to

a second signal. The user may output these signals as stereo or sum them to produce a dual mono signal.

5.Connect power cords to the MPA 152 MD and other audio equipment.

6.Adjust the MPA 152 MD input level, bass, and treble (see the figure below).

LEVEL BASS TREBLE

Captive Screw Connector

POWER

Power Receptacle

12V

3A MAX

2-Pole Captive Screw

Connector

MPA 152 MD

MINI POWER AMPLIFIER

a. If connecting the amplifier to a projector, set the projector volume to its lowest point.

 

 

 

 

Tie Wrap

 

 

 

 

 

 

Then adjust the MPA 152 MD level potentiometer fully counterclockwise.

 

 

 

 

b.Set the projector volume to its maximum volume level (no sound should come out).

c.Return to the MPA 152 MD and raise the level until sound distortion first occurs, then lower slightly until the distortion disappears. This setting ensures that, whatever the projector volume setting may be, no clipping occurs.

d.Adjust bass and treble to preference.

7.The 3-pole Remote captive screw connector on the MPA 152 MD is used for remote control of the volume when using a third party remote control option with a projector that lacks variable audio outputs. The volume can also be controlled by IR remote control of the projector volume (see the MPA 152 MD User Guide).

CAUTION: All accessory equipment must be UL-listed. For more information, see the "MPA 152 MD Application Notes" section, in the MPA 152 MD User Guide.

Extron USA - West

Extron USA - East

Extron Europe

Extron Asia

Extron Japan

Extron China

Extron Middle East

 

Headquarters

 

 

 

 

 

 

 

+800.633.9876

+800.633.9876

+800.3987.6673

+800.7339.8766

+81.3.3511.7655

+400.833.1568

+971.4.2991800

68-1989-50

Inside USA/Canada Only

Inside USA/Canada Only

Inside Europe Only

Inside Asia Only

+81.3.3511.7656 FAX

Inside China Only

+971.4.2991880 FAX

+1.714.491.1500

+1.919.863.1794

+31.33.453.4040

+65.6383.4400

 

+86.21.3760.1568

 

Rev A

+1.714.491.1517 FAX

+1.919.863.1797 FAX

+31.33.453.4050 FAX

+65.6383.4664 FAX

 

+86.21.3760.1566 FAX

 

11 10

© 2010 Extron Electronics. All Rights Reserved. www.extron.com

Image 1